    SOR-96-118:en — Regulations Respecting Oil and Gas Installations Used in Areas of Canada Under the Canada Oil and Gas Operations Act

    Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.

    Analyze this law with AI
    1 These Regulations may be cited as the Canada Oil and Gas Installations Regulations. 2 (1) In these Regulations, accidental event means an unplanned or unexpected event or circumstance or series of events or circumstances that may lead to loss of life or damage to the environment; (événement accidentel) accommodation area means dependent personnel accommodation or an accommodation installation (secteur d’habitation) accommodation installation means an installation that is used to accommodate persons at a production site or drill site and that functions independently of a production installation, drilling installation or diving installation, and includes any associated dependent diving system; (installation d’habitation) Act means the Canada Oil and Gas Operations Act; (Loi) certificate of fitness means a certificate issued by a certifying authority in accordance with section 4 of the Canada Oil and Gas Certificate of Fitness Regulations; (certificat de conformité) certifying authority has the same meaning as in section 2 of the Canada Oil and Gas Certificate of Fitness Regulations; (autorité) Chief means the Chief Safety Officer; (délégué) classification society means an independent organization whose purpose is to supervise the construction, ongoing maintenance and any modifications of an offshore platform in accordance with the society’s rules for classing offshore platforms and includes the American Bureau of Shipping, Lloyd’s Register of Shipping, Det norske Veritas Classification A/S and Bureau Veritas; (société de classification) contingency plan means a plan that addresses abnormal conditions or emergencies that can reasonably be anticipated; (plan d’urgence) control point means a work area other than a control station from which systems and equipment critical to the safety of the installation can be monitored and controlled; (poste de commande) control station means a continuously manned work area from which process and export equipment, wellhead manifold and christmas trees, main and emergency power, fire and gas detection, fire control, communications equipment, emergency shutdown systems, ballast control system, dynamic positioning systems and other systems and equipment critical to the safety of the installation are remotely controlled or monitored; (salle de commande) damaged condition means, with respect to a floating platform, the condition of the platform after it has suffered damage to the extent described in the Code referred to in subsection 57(9); (condition avariée) dependent diving system means a diving system that is associated with an installation other than a diving installation and that does not function independently of the installation; (système de plongée non autonome) dependent personnel accommodation means personnel accommodation that is associated with an installation other than an accommodation installation and that does not function independently of the installation; (logement du personnel connexe) development plan means a development plan relating to the development of a pool or field that is referred to in section 5.1 of the Act; (plan de mise en valeur) development plan approval means the approval of a development plan pursuant to section 5.1 of the Act; (approbation de plan de mise en valeur) diving installation means a diving system and any associated vessel that function independently of an accommodation installation, production installation or drilling installation; (installation de plongée) Diving Program Authorization means an authorization to conduct a diving program that is issued to an operator pursuant to paragraph 5(1)(b) of the Act; (autorisation de programme de plongée) diving system means the plant or equipment used in or in connection with a diving operation, and includes the plant and equipment that are essential to a diver or to a pilot of a manned submersible; (système de plongée) drilling base means the stable foundation on which a drilling rig is installed, and includes the ground surface, an artificial island, an ice platform, a platform fixed to the ground or seafloor and any other foundation specially constructed for drilling operations; (base de forage) drilling installation means a drilling unit or a drilling rig and its associated drilling base, and includes any associated dependent diving system; (installation de forage) Drilling Program Authorization means an authorization to conduct a drilling program that is issued to a person pursuant to paragraph 5(l)(b) of the Act; (autorisation de programme de forage) drilling rig means the plant used to make a well by boring or other means, and includes a derrick, draw-works, rotary table, mud pump, blowout preventer, accumulator, choke manifold, dependent personnel accommodation and other associated equipment, including power, control and monitoring systems; (appareil de forage) drilling unit means a drillship, submersible, semi-submersible, barge, jack-up or other vessel that is used in a drilling program and is fitted with a drilling rig, and includes other facilities related to drilling and marine activities that are installed on a vessel or platform; (unité de forage) drill site means a location where a drilling rig is or is proposed to be installed; (emplacement de forage) environmental load means a load imposed by waves, currents, tides, wind, ice, sea ice, snow, an earthquake or any other naturally occurring phenomenon, or by any combination of those phenomena; (charge environnementale) floating platform means a column-stabilized mobile offshore platform or a surface mobile offshore platform; (plate-forme flottante) flowline means a pipeline that is used to transport fluids from a well to a production facility or vice versa, and includes intrafield export and all gathering lines; (conduite d’écoulement) gastight door means a solid, close-fitting door designed to resist the passage of gas under normal operating conditions; (porte étanche aux gaz) hazardous area means an area classified as hazardous in the Recommended Practice referred to in subsection (2); (zone dangereuse) installation means a diving installation, a drilling installation, a production installation or an accommodation installation; (installation) intact condition means, with respect to a floating platform, that the platform is not in a damaged condition; (condition intacte) machinery space means a space on an installation where equipment incorporating rotating or reciprocating mechanical equipment in the form of an internal combustion engine, a gas turbine, an electric motor, a generator, a pump or a compressor is located; (zone des machines) major damage means damage that results in uncontrolled pollution or loss of or serious threat to life; (dommage majeur) manned offshore installation means an offshore installation on which persons are normally present; (installation habitée au large des côtes) marine activities means activities related to position keeping and collision avoidance of mobile offshore platforms including mooring, dynamic positioning and ballasting; (activité maritime) mobile offshore platform means an offshore platform that is designed to operate in a floating or buoyant mode or that can be moved from place to place without major dismantling or modification, whether or not it has its own motive power; (plate-forme mobile au large des côtes) new installation means an installation that is constructed after the coming into force of these Regulations; (nouvelle installation) non-combustible material means material that does not burn or give off flammable vapours in sufficient quantity for self- ignition when heated to 750°C; (matériau incombustible) offshore drill site means a drill site within a water-covered area that is not an island, an artificial island or an ice platform; (emplacement de forage au large des côtes) offshore installation means an installation that is located at an offshore production site or offshore drill site, and includes an accommodation installation and a diving installation; (installation au large des côtes) offshore loading system means the equipment and any associated platform or storage vessel located at an offshore production site to load oil or gas on a transport vessel, and includes any equipment on the transport vessel that is associated with the loading system; (système de chargement au large des côtes) offshore production site means a production site within a water-covered area that is not an island, other than an artificial island, or an ice platform; (emplacement de production au large des côtes) operating condition, with respect to a mobile offshore platform, means the condition of operating at the operating draft; (condition d’exploitation) operating draft, with respect to a mobile offshore platform, means the vertical distance in metres from the moulded baseline to the assigned waterline, where the platform is operating under combined environmental and operational loads that are within the limits for which the platform was designed to operate; (tirant d’eau d’exploitation) operations manual means the manual referred to in section 64; (manuel d’exploitation) operator means a person who has applied for or has been granted a Production Operations Authorization, a Drilling Program Authorization or a Diving Program Authorization; (exploitant) platform means a platform associated with an installation; (plate-forme) production facility means equipment for the production of oil or gas located at a production site, including separation, treating and processing facilities, equipment and facilities used in support of production operations, landing areas, heliports, storage areas or tanks and dependent personnel accommodations, but not including any associated platform, artificial island, subsea production system, drilling equipment or diving system; (matériel de production) production installation means a production facility and any associated platform, artificial island, subsea production system, offshore loading system, drilling equipment, facilities related to marine activities and dependent diving system; (installation de production) production operation means an operation that is related to the production of oil or gas from a pool or field; (travaux de production) Production Operations Authorization means an authorization to conduct production operations issued to an operator pursuant to paragraph 5(1)(b) of the Act; (autorisation d’exécuter des travaux de production) production site means a location where a production installation is or is proposed to be installed; (emplacement de production) subsea production system means equipment and structures that are located on or below or buried in the seafloor for the production of oil or gas from, or for the injection of fluids into, a field under an offshore production site, and includes production risers, flow lines and associated production control systems; (système de production sous-marin) survival condition, with respect to a mobile offshore platform, means the condition of the platform when it is subjected to the most severe environmental conditions determined pursuant to section 45; (condition de survie) survival draft, with respect to a mobile offshore platform, means the vertical distance in metres from the moulded baseline to the assigned waterline, where the platform is subjected to the most severe environmental conditions determined pursuant to section 45; (tirant d’eau de survie) transit draft, with respect to a mobile offshore platform, means the vertical distance in metres from the moulded baseline to the assigned waterline, when the platform is moving from one geographical location to another; (tirant d’eau de transit) unmanned offshore installation means an offshore installation on which persons are not normally present and in those instances when persons are present on the installation, their presence is for the purpose of performing operational duties, maintenance or inspections that will not necessitate an overnight stay; (installation inhabitée au large des côtes) watertight means designed and constructed to withstand a static head of water without any leakage; (étanche à l’eau) working area means any area of an installation that a person may occupy during the normal course of duties, and includes a control room, a workshop, machinery space, storage area and paint locker. (zone de travail) (2) Subject to subsection 9(2), for the purposes of sections 10, 11, 13, 14, 19 and 33, the classification of hazardous areas with respect to hazards caused by combustible gases on an installation shall be made in accordance with American Petroleum Institute RP 500, Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities. (3) A reference to a standard or specification shall be considered to be a reference to that standard or specification as amended from time to time. 3 For the purpose of ensuring the safety of an installation, no operator shall use the installation unless the equipment on the installation is arranged in accordance with these Regulations to (a) provide for the safety of personnel; (b) minimize damage to the environment; and (c) enable easy access to the equipment. 4 (1) Every new installation shall be designed, constructed, installed and commissioned in accordance with a quality assurance program that complies with subsection (2) and that is selected in accordance with Canadian Standards Association CAN3-Z299.0-86, Guide for Selecting and Implementing the CAN3-Z299-85 Quality Program Standards. (2) A quality assurance program shall be developed in accordance with (a) Canadian Standards Association CAN3-Z299.l-85, Quality Assurance Program — Category 1; (b) Canadian Standards Association CAN3-Z299.2-85, Quality Control Program — Category 2; (c) Canadian Standards Association CAN3-Z299.3-85, Quality Verification Program — Category 3; and (d) Canadian Standards Association CAN3-Z299.4-85, Inspection Program — Category 4. 5 (1) Every helicopter deck or facility that forms part of an offshore installation shall (a) conform to Transport Canada TP 4414, Guidelines Respecting Helicopter Facilities on Ships; and (b) be equipped so that any fuel stored on or adjacent to the helicopter deck or to the accommodation areas (i) can be jettisoned by action taken at another location on the installation, or (ii) is protected against damage or impact. (2) Every helicopter deck that forms part of an offshore installation shall be in a location that is readily accessible to and from the dependent personnel accommodation of the installation. (3) Every helicopter facility that forms part of an onshore installation shall conform to Transport Canada TP2586E, Heliport and Helideck Standards and Recommended Practices. 6 An offshore installation shall be designed and equipped in such a manner as to allow for the monitoring, maintenance and periodic inspection of the installation, including (a) clear marking and identification of the areas to be inspected; (b) provision for safe access to and adequate inspection space for the areas to be inspected; (c) space for the storage and operation of diving equipment; (d) means to facilitate the work of divers, where inspection by divers is required; (e) means to assist maintenance personnel, including those doing underwater maintenance, to perform their work safely and effectively; and (f) in the case of a mobile offshore platform that is not intended to be periodically drydocked, means to facilitate on- location inspection of the hull. 7 All decks, deckhouses, skids, modules and other structures located or installed on an offshore installation shall be capable of withstanding all the loads and forces to which they will be subjected, as determined in accordance with section 45. 8 (1) In this section flame-type equipment means any electric or fired heating equipment that uses an open flame, electric arc or element, and includes a space heater, a torch, a heated process vessel, a boiler, an electric arc or an open flame welder, or an open element electric heater or appliance; (équipement de type à flamme) process vessel means a heater, dehydrator, separator, treater or vessel used in the processing or treatment of produced gas or oil. (récipient de fabrication) (2) No person shall create or cause to be created any unprotected flame or source of ignition within 50 m of a well, an oil storage tank or other source of ignitable vapour. (3) No oil storage tank shall be placed or remain within 50 m of an onshore well. (4) No flame-type equipment shall be placed or operated within 25 m of a well, an oil storage tank or other source of ignitable vapour, except (a) where the well is (i) a water supply well, or (ii) a water injection well equipped with a suitable packer and with the surface casing annulus vented outside any building; or (b) where emergency work requires the use of flame-type equipment and the wellhead valves and blow-out preventer, if any, are closed. (5) No flame-type equipment shall be placed or operated within 25 m of a process vessel, unless the flame type equipment is fitted with an adequate flame arrester. (6) No flame-type equipment shall be located in the same building as a process vessel or other source of ignitable vapour, unless (a) the air intakes and flues of all burners are located outside the building; (b) relief valves, safety heads and other sources of ignitable vapours are vented outside the building and discharged above roof level; and (c) the building is adequately cross-ventilated. (7) All process vessels and equipment from which ignitable vapour may issue shall be vented to the atmosphere, and all vent lines from every storage tank that is vented to flare pits or flare stacks shall be provided with flame arresters or other equivalent safety devices. (8) An exhaust pipe from an internal combustion engine located within 25 m of a well, a process vessel, an oil storage tank or other source of ignitable vapour shall be constructed so that (a) any emergence of flame along its length or at its end is prevented; and (b) the end is at least 6 m from the vertical centre line of the well projected upward and shall be directed away from the well. (9) All equipment at or near a well, a process vessel, an oil storage tank or other source of ignitable vapour shall be constructed in accordance with Part I of the Canadian Electrical Code Part I and the Oil and Gas Occupational Health and Safety Regulations. 9 (1) Subject to subsection (2), there shall not be direct access or any opening in an installation between (a) a non-hazardous area and a hazardous area; or (b) a Class I, Division 2, hazardous area and a Class I, Division 1, hazardous area. (2) Subject to subsections (3) to (5), an enclosed area that has direct access to, and that is classified as less hazardous than, a Class I, Division 1, hazardous area or a Class I, Division 2, hazardous area shall be considered to have the same classification as the area to which it has direct access. (3) An enclosed area that has direct access to a Class I, Division 1, area shall be considered to be a Class I, Division 2, hazardous area if (a) the access is fitted with a self-closing gastight door that opens into the enclosed area; and (b) when the door is open, the air flows from the enclosed area into the Class I, Division 1, hazardous area. (4) An enclosed area shall not be considered to be a hazardous area because of its direct access to a Class I, Division 2, hazardous area if (a) the access is fitted with a self-closing gastight door that opens into the enclosed area; and (b) when the door is open, the air flows from the enclosed area into the Class I, Division 2, hazardous area. (5) An enclosed area shall not be considered to be a hazardous area because of its direct access to a Class I, Division 1, hazardous area if (a) the access is fitted with self-closing gastight doors forming an air-lock; and (b) the enclosed area is maintained at a pressure that is higher than the pressure maintained in the Class I, Division 1, hazardous area. (6) Piping systems on an installation shall be designed to preclude direct communications between hazardous areas of different classifications and between hazardous and non-hazardous areas. 10 (1) Every enclosed hazardous area on an installation shall be ventilated. (2) The ventilation systems fitted on an offshore installation for the purpose of subsection (1) shall be capable of replacing the air in the hazardous area at the rate of once every five minutes. (3) Where a mechanical ventilation system is used for the purpose of subsection (1), the air in the enclosed hazardous area shall be maintained at a pressure that is lower than the pressure of each adjacent hazardous area that is classified as less hazardous. (4) All air let into an enclosed hazardous area shall be taken from a non-hazardous area, and where the inlet duct passes through a hazardous area classified as more hazardous than the one to which the duct leads, the air in the inlet duct shall be maintained at a pressure that is higher than the pressure of the air in the hazardous area through which it passes. (5) All air let out of an enclosed hazardous area shall be let into an outdoor area that would be classified as the same as or less hazardous than the enclosed hazardous area if it did not receive the air from the enclosed hazardous area. (6) The ventilation system for every non-hazardous area shall be separate from the ventilation system for every hazardous area, and the ventilation fan inlets and outlets shall be arranged to prevent the air from a hazardous area from moving, as a result of the operation of any fan or the wind, into an area classified as less hazardous. (7) Every ventilation outlet duct leading from a non-hazardous area where drilling or production operations are conducted to a Class I, Division 2, hazardous area shall be equipped with self-closing shutters and a gas detector. (8) A differential pressure gauge shall be installed to monitor any loss of ventilation pressure differential required by subsection (3) or (4) or maintained under section 9, and to activate audible and visual alarms at the appropriate control point after a suitable period of delay not exceeding 30 seconds if a loss occurs. (9) The control station and all accommodation areas on an installation shall (a) be maintained at a positive overpressure relative to atmospheric pressure; and (b) have airlock arrangements on all external doors. (10) The power for a mechanical ventilation system provided in accommodation areas, working areas, flammable liquid storage areas and other hazardous locations of an installation shall be capable of being shut off from the control station and from a position that is outside the area being served by the ventilation system and that will remain accessible during any fire that may occur within the area being ventilated. (11) The main inlets and outlets of all ventilation systems shall be capable of being closed from a position that is outside the area being served by the ventilation system and that will remain accessible during any fire that may occur within the area being ventilated. 11 (1) Subject to subsections (2) to (4), all electric motors, lighting fixtures, electric wiring and other electrical equipment on an installation shall be designed, installed and maintained in accordance with (a) in the case of an onshore installation, Canadian Standards Association Standard C22.l-l990, Canadian Electrical Code Part I, Safety Standard for Electrical Installations; and (b) in the case of an offshore installation, American Petroleum Institute RP l4F, Recommended Practice for Design and Installation of Electrical Systems for Offshore Production Platforms. (2) Electrical wiring on an offshore installation shall be (a) designed in accordance with International Electrotechnical Commission Publication 92-3, Electrical Installations in Ships, Part 3: Cables (construction, testing and installations) and tested for Category A in accordance with International Electrotechnical Commission Publication 332-3, Tests on electrical cables under fire conditions, Part 3: Tests on bunched wires or cables; and (b) tested for impact at -35°C and bending at -40°C in accordance with Canadian Standards Association Standard C22.2 No. 0.3-M1985, Test Methods for Electrical Wires and Cables. (3) Where a primary or secondary distribution system for power, heating or lighting, with no connection to earth, is used on an offshore installation, a device capable of continuously monitoring the insulation level to earth and of giving an audible or visual indication of abnormally low insulation values shall be provided. (4) The primary source of electrical power on every offshore installation shall (a) include at least two power plants; (b) be capable of supporting all normal operations without recourse to the emergency source of electrical power required by section 12; and (c) if one of the power plants is out of operation, be capable of supporting all operations except drilling and production operations. (5) The primary circuits from the power plant serving an installation shall be equipped with at least two manual shut-off switches, each at a different location. 12 (1) Every offshore installation shall have an emergency source of electrical power that is independent of the primary source of electrical power and that is capable of supplying electrical power sufficient to operate, for at least twenty-four hours, the following equipment: (a) all lights referred to in subsection (2); (b) all gas detection and alarm systems; (c) all fire detection and alarm systems; (d) all firefighting systems except any fire pump that is driven by a liquid fuelled combustion engine; (e) the general alarm system and all internal communication systems; (f) the emergency shut down system referred to in section 18; (g) all lifesaving systems; (h) all navigation lights, sound signal systems and illuminated markings, that are required by section 21; (i) all radio communication equipment necessary to comply with the contingency plans referred to in section 44; (j) on a mobile offshore platform, the main ballast control system, one ballast pump for each individual ballast system and one bilge pump for each individual bilge system; (k) on a column-stabilized mobile offshore platform, the secondary ballast control system; (l) all equipment necessary to secure the production or drilling operations in progress at any one time in a safe manner, including a well disconnect system; (m) if a pumping system is required under paragraph (l), one pump that is not driven by an internal combustion engine that has sufficient capacity to kill any well on the installation; (n) any blow-out prevention system; and (o) any manned diving equipment dependent on an electrical supply. (2) Every offshore installation shall be equipped with lights supplied by the emergency source of power described in subsection (1), in the following locations: (a) every embarkation station on deck and over sides; (b) every escape route and area containing escape route markings; (c) all service corridors and corridors in accommodation areas, and all stairways, exits and personnel lift cars; (d) all machinery spaces and main generating stations; (e) the control station and all control points; (f) all spaces from which the drilling and production operations are controlled and at which controls of machinery essential for the performance of those operations and devices for the emergency shut-down of the power plant are located; (g) the stowage positions for firefighting equipment; (h) each sprinkler pump and fire pump and each ballast and bilge pump, referred to in paragraph (1)(j), and the starting position for each pump; (i) every helicopter landing deck and every obstacle marker on that deck; and (j) the radio room. (3) Where the emergency source of electrical power required by subsection (1) is a mechanically driven generator, the offshore installation shall be provided with (a) a transitional source of electrical power, unless the generator will automatically start and supply the power required by subsection (1) in less than 45 seconds from the time the primary source of electrical power fails; and (b) a self-contained battery system designed to supply sufficient power, automatically on failure or shutdown of both the primary and the emergency sources of electrical power, to operate, for a period of at least one hour the equipment described in subparagraphs (i) and (ii) and, for a period of at least four days, the equipment described in subparagraph (iii): (i) the lights located in every emergency exit route, at every escape route, in every machinery space, the control station and every emergency assembly room and at every launching station of the lifesaving system, (ii) the internal communication system and the general alarm system, and (iii) the navigation lights, sound signal systems and illuminated markings referred to in section 21. (4) The battery system referred to in paragraph (3)(b) shall be capable of returning to the trickle charge state on restoration of the primary or emergency source of electrical power. (5) The emergency source of electrical power required by subsection (1) shall, for a floating platform, be designed to function at full rated power when the installation is upright and when it is at any inclination up to a maximum angle of (a) 22½ degrees about the longitudinal axis and 10 degrees about the transverse axis, in the case of a surface mobile offshore platform; (b) 25 degrees in any direction, in the case of a column- stabilized mobile offshore platform; and (c) 15 degrees in any direction, in the case of a self-elevating platform. (6) The location of the emergency source of electrical power and associated fuel storage, the transitional source of power, if any, and the emergency switchboard on an offshore installation shall be (a) readily accessible from an open deck space; (b) segregated by class A-60 divisions, as defined in subsection 23(1), from any space containing the main source of electrical power or the internal combustion engines; (c) outside any hazardous area; and (d) for a floating platform, located above the waterline that would exist if the platform were in a damaged condition and in a space outside any part of the platform if it were in that damaged condition. (7) Every onshore drilling rig except a drilling rig located on an ice platform shall have an emergency source of electrical power that is independent of the primary source of electrical power and that is capable of supplying electrical power sufficient to operate, for at least twenty-four hours, the following equipment: (a) all warning systems; (b) all emergency lighting; (c) the general alarm system and internal communication system; (d) all fire extinguishing systems, except any fire pump that is driven by an internal combustion engine that is liquid fuelled; and (e) all equipment necessary to secure production or drilling operations in progress at any one time in a safe manner, including a well control system. (8) Every drilling rig that is located on an ice platform shall have an emergency source of electrical power that is (a) capable of supplying electrical power sufficient to operate, for at least twenty-four hours, any well disconnect system; (b) independent of the primary source of electrical power; and (c) remote from the machinery housing. (9) The emergency source of electrical power required by subsection (1), (7) or (8) shall be designed to supply electrical power automatically, on failure of the primary source of electrical power, to a switchboard that is designed to direct the power to the equipment listed in that subsection. 13 (1) Every internal combustion engine on an installation shall be installed, maintained and operated in accordance with American Petroleum Institute RP 7C-llF, Recommended Practice for Installation, Maintenance and Operation of Internal-Combustion Engines. (2) Combustion air for every internal combustion engine and fired vessel shall be taken from non-hazardous areas. (3) Exhaust gas from every internal combustion engine and fired vessel shall be discharged to non-hazardous areas. (4) The air induction system of every diesel engine operating in a hazardous area shall be equipped with (a) a flame arrester in the induction system; (b) a shut-off valve that is located between the engine air inlet filter and the induction system flame arrester and that is capable of being closed automatically by the engine overspeeding device and manually; (c) a flame arrester in the exhaust system; and (d) a spark arrester in the exhaust system, downstream of the flame arrester. (5) Subject to subsection (13), the fuel supply system for every diesel engine shall be equipped with a manual shut-off device and, except for the emergency source of electrical power required by section 12, with a device that will automatically shut off the fuel supply if any of the following occur: (a) overspeeding; (b) high exhaust temperature; (c) high cooling water temperature; or (d) low lubricating oil pressure. (6) The engine crankcase breather pipe on every diesel engine shall (a) be equipped with a flame arrester; and (b) in the case of an engine in an enclosed Class I, Division 2, hazardous area, lead to the atmosphere outside the installation. (7) Basic operating instructions for every diesel engine shall give details of stop, start and emergency procedures and be permanently attached to the engine. (8) The layout of every gas turbine, including the location of the control points, shall take into account the ability of the control point closest to the turbine to withstand pressure waves in the event of an explosion in the gas turbine exhaust duct or gas turbine hall and the effects of the failure of a gas turbine rotor where the fragments cannot be contained. (9) Every gas turbine shall have, in addition to the speed governor, a separate overspeed device, arranged and adjusted so that the manufacturer’s overspeed limitations for the turbine cannot be exceeded by more than 15 per cent. (10) The air intakes and exhaust for every gas turbine shall be arranged to prevent, to the extent practicable, reingestion of combustion gases. (11) Every multi-engine gas turbine shall have a separate air intake and exhaust, arranged so as to prevent induced circulation through a stopped turbine. (12) All machinery, components and systems essential to the operation of a floating platform shall be designed to function at full rated power at any inclination, up to a maximum angle of (a) in the case of a surface mobile offshore platform, (i) 15 degrees in any direction under static conditions, (ii) 22½ degrees in any direction under rolling dynamic conditions, and (iii) 7½ degrees by bow or stern under rolling dynamic conditions; (b) for a column-stabilized mobile offshore platform, 15 degrees in any direction; and (c) for a self-elevating platform, 10 degrees in any direction. (13) The automatic shut-off device referred to in subsection (5) shall shut off the fuel supply to engines associated with fire pump systems only where overspeeding occurs. (14) Jacking mechanisms for self-elevating platforms shall, where possible, be arranged with redundancy so that a single failure of any component does not cause an uncontrolled descent of the platform. 14 (1) Every installation shall be designed, constructed, equipped and insulated to ensure that, at the minimum air temperature that may occur at the drill site or production site during operations, based on an annual probability of exceedance of 10-2, (a) in the case of a production installation, the production equipment and other associated equipment will operate in a safe and efficient manner; (b) the emergency shutdown system referred to in section 18 will perform its intended functions; (c) drilling safety systems and associated equipment will operate safely and in accordance with the manufacturer’s specifications; (d) the fluids in the following systems and components will not freeze, namely, (i) fresh water tanks and the associated piping, (ii) vent pipes, (iii) components of the drainage system, (iv) the hydraulic system and its components, including operators and cylinders, and (v) the firefighting system, including pump drives and fuel supply lines, fire pumps and associated piping, fire hydrants, fire hoses and nozzles; (e) every pneumatic control system will remain fully operational at all times; (f) the lifesaving appliances and associated devices will remain operational; and (g) in the case of a mobile offshore platform, (i) the fluid in an operating ballast system, including the pumps, control systems and associated piping and valves, is protected against freezing, (ii) the proper functioning of any thrusters is not impaired and the hydraulic fluid and lubricants for the thrusters have properties designed for such a temperature, and (iii) the mooring winches and, where the platform is so equipped, the quick disconnect system will remain fully operational. (2) Every installation shall be equipped with steam-generating equipment, or an equivalent means, that will keep the locations mentioned in subsection (3) free of ice and snow and lines thawed so as to permit drilling, production and maintenance operations to be conducted safely. (3) Every installation that is equipped with steam-generating equipment, or an equivalent means, required by subsection (2) shall include outlets, hoses and hose clamps capable of being used in the following locations: (a) work areas; (b) walkways; and (c) in the case of an offshore installation, the helicopter deck and the lifeboat embarkation stations. (4) Where temperatures below -20°C may occur, based on an annual probability of exceedance of 10-2, at the drill site or production site more than one day per year and where the installation is equipped with steam-generating equipment, or an equivalent means, required by subsection (2), (a) that equipment shall meet the requirements set out in subsection (2) when operating at 75 per cent capacity; and (b) the installation shall be equipped with a second set of steam-generating equipment or another means of providing equivalent protection against ice, snow and freezing. 15 (1) All structural elements that are part of an offshore installation and the failure of which as a result of corrosion would cause a safety hazard shall be protected or constructed with extra material so as to prevent the degree of corrosion that may cause that structural element to fail and shall be protected against corrosion in accordance with section 4.15 of Canadian Standards Association CAN/CSA-S471-92, General Requirements, Design Criteria, the Environment, and Loads. (2) Corrosion protection systems for offshore installations shall be designed, installed and maintained in accordance with (a) section 15 of Canadian Standards Association CAN/CSA-S473-92, Steel Structures, Offshore Structures, in the case of steel platforms; and (b) sections 4.9.5, 5.1.1, 5.3, 5.4.2, 5.6, 5.10 and 11.19 of Canadian Standards Association Preliminary Standard S474-M1989, Concrete Structures, in the case of concrete platforms. (3) All corrosion protection systems on an offshore installation shall be designed so that adjustment, repair or replacement can be done on site, except where (a) dry dock surveys are possible and are scheduled at a frequency of five years or less; or (b) the corrosion protection system is a cathodic protection system that has a design life exceeding that of the installation. 16 Every crane on an offshore installation shall (a) be designed and constructed in accordance with American Petroleum Institute Spec 2C, Specification for Offshore Cranes; and (b) be operated and maintained in accordance with American Petroleum Institute RP 2D, Recommended Practice for Operation and Maintenance of Offshore Cranes. 17 (1) In this section, gas release system means a system for releasing gas and combustible liquid from an installation, and includes a flare system, a pressure relief system, a depressurizing system and a cold vent system. (2) Every gas release system shall be designed and located, taking into account the amount of combustibles to be released, the prevailing winds, the location of other equipment and facilities, including rigs, the dependent personnel accommodation, the air intake system, embarkation points, muster areas, the helicopter approaches and other factors affecting the safe, normal flaring or emergency release of the combustible liquid, gases or vapours, so that when the system is operating it will not damage the installation, other installations, the land or other platforms in the vicinity used for the exploration or exploitation of resources, or injure any person. (3) Every gas release system shall be designed and installed in accordance with (a) American Petroleum Institute RP 520, Recommended Practice for the Design and Installation of Pressure-Relieving Systems in Refineries; (b) American Petroleum Institute RP 521, Guide for Pressure-Relieving and Depressuring Systems; (c) American Petroleum Institute Standard 526, Flanged Steel Safety-Relief Valves; (d) American Petroleum Institute Standard 527, Seat Tightness of Pressure Relief Valves; and (e) American Petroleum Institute Standard 2000, Venting Atmospheric and Low-Pressure Storage Tanks. (4) Every gas release system shall be designed and constructed to ensure that oxygen cannot enter the system during normal operation. (5) Any flare boom and its associated equipment shall be designed (a) to ensure a continuous flame using an automatic igniter system; (b) to withstand the radiated heat at the maximum venting rate; (c) to prevent flashback; and (d) to withstand all loads to which they may be subjected. (6) Every gas release system shall be designed to limit to the acceptable levels permitted by the Oil and Gas Occupational Safety and Health Regulations the noise that may occur as the gas expands. (7) With the exception of water, any liquid that cannot be safely and reliably burned at the flare tip of a gas release system shall be removed from the gas before it enters the flare. (8) Any vent that is used to release gas to the atmosphere without combustion shall be located and designed to minimize the risk of accidental ignition of the gas. (9) Every gas release system shall be designed and installed so that, taking into account the prevailing wind conditions, the maximum radiation on areas where personnel may be located, from the automatically ignited flame of a flare or vent, will be (a) 6.3 kW/m2, where the period of exposure will not be greater than one minute; (b) 4.72 kW/m2, where the period of exposure will be greater than one minute but not greater than one hour; and (c) l.9 kW/m2, where the period of exposure will be greater than one hour. 18 (1) Every installation shall have an emergency shutdown system that is capable of shutting down and isolating all potential sources of ignition and sources of flammable liquids or gases. (2) An emergency shutdown system shall be designed and installed so that when activated it causes (a) an audible and visual signal that indicates the cause of its activation and the identity of the equipment that has been shut down and isolated to be given in the appropriate control point; and (b) an audible alarm to be sounded through the general alarm system required by section 34 unless the alarm is overridden by the control point operator. (3) In the case of a production installation, an emergency shutdown system shall be designed to ensure (a) that there are at least two levels of shutdown; and (b) subject to subsection (13), that the following will occur within the time and in the sequence set out in the operations manual: (i) the shutdown of all production facilities and associated test facilities, (ii) the closure of all surface inlet manifold safety valves and production riser safety valves, (iii) the closure of all Christmas tree safety valves and all downhole safety valves, and (iv) the shutdown of all utilities except the equipment listed in subsection 12(1). (4) In the case of a production installation, manual operation of an emergency shutdown system shall be in accordance with American Petroleum Institute RP 14C, Recommended Practice for Analysis, Design, Installation and Testing of Basic Surface Safety Systems for Offshore Production Platforms. (5) In the case of a drilling installation, an emergency shutdown system shall be designed to ensure (a) the shutdown within the time and in the sequence set out in the operations manual of all utilities, except the equipment listed in subsection 12(1); and (b) that shutdown is possible from at least two strategic locations. (6) The emergency shutdown system shall be designed to permit the selective shutdown of the ventilation systems required by section 10, except the fans necessary for supplying combustion air to prime movers for the production of electrical power. (7) At least one of the controls of the emergency shutdown system shall be located outside hazardous areas. (8) After an emergency shutdown, the emergency shutdown system shall stay in a locked-out condition until it is manually reset. (9) The emergency shutdown system shall be connected to a source of power in such a way that, in the event of a failure of the primary source of power, there is automatic changeover to an emergency source of power and audible and visual alarms indicating that failure are given at the appropriate control point. (10) Where a hydraulic or pneumatic accumulator is used to operate any part of the emergency system, the accumulator shall (a) be located as close as is practicable to the part that it is designed to operate, except where that part is part of a subsea production system; and (b) have capacity for at least three operations. (11) In the event of a failure of the accumulator referred to in subsection (10), the shutdown valves shall revert to a fail-safe mode. (12) All cables and pneumatic and hydraulic power lines that are part of the emergency shutdown system shall (a) in the case of cables and power lines that are exposed to the risk of mechanical or fire damage, be protected (i) by metal channels or casings, or (ii) by being enclosed in a steel conduit or an equivalent covering; and (b) as far as practicable, be segregated or routed away from the process and utility control systems so that any damage to those systems does not affect the shutdown system. (13) In the case of a production installation, on activation of the emergency shutdown system, the surface-controlled subsurface safety valve shall close in not more than two minutes after the Christmas tree safety valve has closed, except where a longer delay is justified by the mechanical or production characteristics of the well. 19 (1) On every onshore installation, (a) every work area shall have at least two well-marked separate escape routes that are situated as far apart as is practicable and that lead to an area away from the drill site or production site; and (b) all corridors that are more than 5 m long, all accommodation areas and, where practicable, all work areas shall have at least two exits, located as far apart as is practicable, that lead to escape routes. (2) On every manned offshore installation, (a) every work area shall have at least two well-marked separate escape routes that are situated as far apart as is practicable; (b) all escape routes shall lead to the open deck and from there to an evacuation station; (c) in addition to the escape routes required by paragraph (a), clear passage shall be provided, where practicable, to the helicopter deck and sea level and other embarkation locations; (d) all corridors that are more than 5 m long, all accommodation areas and, where practicable, all work areas shall have at least two exits, located as far apart as is practicable, that lead to escape routes; (e) every escape route and embarkation station shall be free of all obstructions, and each exit door along the route shall be a sliding door or designed to open outwards; (f) every escape route leading to an upper level shall, where practicable, be provided in the form of ramps or stairways; (g) every escape route leading to a lower level shall, where practicable, be provided in the form of ramps, stairways or chutes of sufficient width to accommodate stretcher bearers with stretchers; (h) suitable means shall be provided, where practicable, for persons to descend from the installation to the water; (i) materials used for escape routes shall have a level of fire durability equivalent to steel; (j) the survival craft evacuation stations located adjacent to the accommodation areas and the associated escape routes from the accommodation areas shall provide fire protection for a period of at least two hours; and (k) all escape routes and associated stairwells shall be appropriately sheltered from the effects of fire and explosion. 20 (1) Subject to subsection (4), every offshore platform shall be designed to withstand accidental impacts with a vessel. (2) Where practicable, every offshore platform shall have a fender system, buoyage system or similar arrangement that will permit the transfer of goods to and from the production installation and a vessel without endangering that production installation or vessel or any person or goods. (3) Subject to subsection (4), every offshore platform, including any fender system, shall be capable of absorbing the impact energy of not less than 4 MJ from a vessel without endangering any person or the environment. (4) Subsections (1) and (3) do not apply to an unmanned offshore platform if any impact described by those subsections will not cause major damage. (5) Every offshore platform shall be designed so that the impact energy referred to in subsection (3) (a) can be totally absorbed in the permanent deformation of the structural element impacted and by the elastic deflection of the platform; and (b) will not be absorbed in the permanent deformation of the vessel. (6) Where a fender system is used to comply with subsection (2), its size and arrangement shall be such that a vessel cannot be trapped under it at low tide. 21 Every offshore installation shall be equipped with the navigation lights and sound signal systems that are required by (a) in the case of a mobile offshore platform, the Collision Regulations, as if the offshore installation were a Canadian vessel; or (b) in the case of a fixed offshore platform, sections 8, 9 and 10 of the Navigable Waters Works Regulations, as if the offshore installation were in waters to which those Regulations apply. 22 (1) Every offshore installation shall be provided with (a) subject to subsection (2), in the case of a manned installation, two or more totally enclosed survival craft that have a combined carrying capacity of at least 200 per cent of the total number of persons on board the installation at any one time, and in the case of an unmanned installation, one or more totally enclosed survival craft that have a combined carrying capacity of at least 100 per cent of the total number of persons on board the installation at any one time; (b) one or more inflatable liferafts, that have a combined capacity for accommodating at least 100 per cent of the total number of persons on board the installation at any one time, and that (i) meet the requirements for inflatable liferafts set out in Schedule XI to the Life Saving Equipment Regulations, as if the liferafts were in waters to which those Regulations apply, (ii) have float free capability, (iii) if embarkation is more than 4.5 m from the waterline at the survival draft, are equipped with a launching device, and (iv) are equipped with Class A equipment as described in Schedule II to the Life Saving Equipment Regulations; (c) in the case of a manned installation, immersion suits for 200 per cent of the total number of persons on board the installation at any one time, that conform to National Standard of Canada CAN/CGSB-65.16-M89, Marine Abandonment Immersion Suit Systems, and that are stowed such that one suit is readily available adjacent to each bed and the remaining suits are equally distributed among evacuation stations; (d) in the case of an unmanned installation, immersion suits for 100 per cent of the total number of persons on board the installation at any one time, that conform to the National Standard of Canada CAN/CGSB-65.16-M89, Marine Abandonment Immersion Suit Systems, and that are equally distributed among evacuation stations; (e) a lifejacket for each of the persons on board the installation at any one time; and (f) in the case of a manned installation, (i) a motor-propelled rescue boat that (A) meets the requirements for rescue boats set out in Regulation 47 of Chapter III of International Maritime Organization International Conference on Safety of Life at Sea, (B) is located under a device capable of launching and retrieving the boat when the boat is fully loaded with equipment and complement, and (C) is self-righting, (ii) lifebuoys that are distributed on the decks of the installation, and that are stowed in a bracket or cleats, in at least the following numbers, namely, (A) 8 lifebuoys for an installation that is 100 m or less in length, (B) 10 lifebuoys for an installation that is more than 100 m but less than 150 m in length, (C) 12 lifebuoys for an installation that is 150 m or more but less than 200 m in length, and (D) 14 lifebuoys for an installation that is 200 m or more in length, (iii) a rescue basket capable of accommodating at least six persons, (iv) 12 Type A distress signals, as defined in the Life Saving Equipment Regulations, (v) a Class I emergency position indicator radio beacon, as defined in the EPIRB Regulations, in each control station, (vi) at least two radar transponders stowed in two widely separated locations, except in the case of surface mobile offshore platforms, (vii) in the case of surface mobile offshore platforms, at least one radar transponder, and (viii) two buoyant personnel transfer baskets. (2) Each of the totally enclosed survival craft provided on an offshore installation shall (a) meet the requirements for Class I lifeboats as set out in Schedule V to the Life Saving Equipment Regulations, as if the survival craft were in waters to which those Regulations apply; (b) be equipped with (i) a compression ignition engine with two independent starting methods and with sufficient power to propel the craft when fully loaded, (ii) an engine block heater, a head bolt heater or any other means of ensuring prompt engine start in cold weather, (iii) a two-way fixed radio capable of permitting communications with other survival, support and rescue craft, (iv) a towing attachment, (v) the equipment required by Schedule I to the Life Saving Equipment Regulations, as if the installation were a Class I ship to which those Regulations apply, (vi) a launching device, (vii) a radar reflector, (viii) a Class II emergency position indicator radio beacon, as defined in the EPIRB Regulations, and (ix) a hand-held radio; (c) be self-righting; (d) be fire-protected; (e) be capable of a speed of not less than 6 knots; (f) have a self-contained air supply sufficient for at least 10 minutes; (g) be stored or equipped (i) in the case of a column-stabilized mobile offshore platform and a fixed platform, so as to launch in a bow out aspect, and (ii) in the case of a self-elevating mobile offshore platform, so as to clear each leg, column, footing, brace or mat and any other similar structure below the hull; (h) be positioned so that half the survival craft are close to the accommodation areas and the other half are appropriately located on the other side of the installation, taking into consideration the shape of the installation and the type of associated facilities; (i) be stowed in a secure and sheltered position that is protected from damage by fire or explosion; and (j) be stowed in such a manner that two crew members can carry out preparations for embarkation and launching in less than 5 minutes. (3) The launching devices for the totally enclosed survival craft, the rescue boat and the inflatable liferafts provided on an offshore installation shall (a) meet the requirements for launching devices set out in Schedule IX to the Life Saving Equipment Regulations, as if the launching devices were located in waters to which those Regulations apply; (b) be sufficiently strong to permit each survival craft, rescue boat or liferaft to be safely launched or lowered into the water when loaded with its full complement of persons and equipment; and (c) situated so as to permit each survival craft, rescue boat or liferaft to be launched clear of any obstruction resulting from damage of the extent described in the Code referred to in subsection 57(9). (4) Half of the lifebuoys provided on an offshore installation shall be equipped with self-igniting lights, and not fewer than two of those lifebuoys shall be equipped with self-activating smoke signals. (5) Two lifebuoys provided on an offshore installation not equipped with lights and smoke signals shall be fitted with a buoyant lifeline, the length of which shall be at least one-and-a-half times the distance from the stowage deck to the waterline at the transit draft, or 30 m, whichever is greater. (6) There shall be posted on every offshore installation, including in the control station and in each accommodation area and work area, copies of a plan showing the position of all the lifesaving appliances. 23 (1) In this section, class A-0 division means a division formed by a bulkhead or deck that is constructed (a) of steel or an equivalent material and suitably stiffened, and (b) to prevent the passage of smoke and flame after 60 minutes of exposure to a standard fire test; (cloisonnement de classe A-0) class A-60 division means a division formed by a bulkhead or deck that is (a) constructed of steel or an equivalent material and suitably stiffened, (b) constructed to prevent the passage of smoke and flame after 60 minutes of exposure to a standard fire test, and (c) insulated with non-combustible materials so that, if either side is exposed to a standard fire test, after 60 minutes the average temperature on the unexposed face will not increase by more than 139°C above the initial temperature and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180°C above the initial temperature; (cloisonnement de classe A-60) class B-15 division means a division formed by a bulkhead, ceiling or lining that is (a) constructed and erected entirely from non-combustible materials, (b) constructed to prevent the passage of flame after exposure to a standard fire test for 30 minutes, and (c) insulated so that if either face is exposed to the first 30 minute period of a standard fire test, the average temperature on the unexposed face will not increase at any time during the first 15 minutes of the test by more than 139°C above that initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 225°C above the initial temperature after exposure for 15 minutes; (cloisonnement de classe B-15) class H-120 division means a division formed by a bulkhead or deck that is (a) constructed of steel or an equivalent material and suitably stiffened, (b) constructed to prevent the passage of smoke and flame after exposure to a hydrocarbon fire test for 120 minutes, and (c) insulated with non-combustible material so that, if either face is exposed to a hydrocarbon fire test, after 120 minutes the ave

    The text continues in the official source.

    Related guides, FAQ and contract templates