    SOR-90-264:en — Regulations Respecting the Construction, Installation and Inspection of Marine Machinery

    Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.

    Analyze this law with AI
    1 These Regulations may be cited as the Marine Machinery Regulations. 2 (1) In these Regulations, Act means the Canada Shipping Act; (Loi) approved classification society means the American Bureau of Shipping, Bureau Veritas (Canada), Det norske Veritas, Lloyd’s Register of Shipping or Germanischer Lloyd; (société de classification agréée) assigned working pressure means the maximum fluid pressure to which the component with the lowest design working pressure in a system may be subjected and above which the system is protected from overpressure; (pression de service effective) auxiliary steering gear means the arrangements provided for effecting movement of the rudder of a ship in the event of failure of the main steering gear, but does not include the rudder stock, tiller or quadrant, or the component serving the same purpose as the tiller or quadrant, or, where fitted, the automatic-pilot system; (appareil à gouverner auxiliaire) boiler means a plant that generates steam or hot water under pressure by means of a flame, combustion gases or electrical heating elements, and includes the superheaters, economizers, valves and components necessary for the safety and operation of the plant; (chaudière) classification society means a society or association for the classification of ships; (société de classification) component means a unit or part of a unit that is identified in rules or codes and is to be installed as part of machinery; (élément) component inspection certificate means a certificate referred to in section 16; (certificat d’inspection d’élément) design working pressure means the maximum fluid pressure to which a component may be subjected during operating conditions; (pression de service nominale) fluid means a gas, vapour or liquid; (fluide) fuel oil unit means the facility, including pressure pumps, filters and heaters, dealing with oil at a pressure in excess of 180 kPa and used in the preparation of fuel oil for delivery to an oil-fired boiler or, where the oil is heated prior to delivery, to an internal combustion engine; (appareil à mazout) harmful substance inspection certificate inspector launch means a ship that has an open cockpit or a cockpit covered by a light trunk cabin in which passengers may be carried; (chaloupe) length means (a) in the case of a Safety Convention passenger ship, the horizontal distance measured between perpendiculars erected at the extreme ends of the deepest subdivision load line, (b) in the case of a ship, other than a Safety Convention passenger ship, that is required to be registered pursuant to the Act, (i) the distance measured from the fore-part of the uppermost end of the stem to the aft side of the head of the stern post, except that where a stern post is not fitted to the ship, it is the distance from the fore-part of the uppermost end of the stem to the foreside of the head of the rudder stock, (ii) where the ship has no rudder stock or has a rudder stock situated outside the hull at the stern, the distance measured from the foreside of the foremost permanent structure to the aft side of the aftermost permanent structure of the ship, but not including guards or rubbing strakes, or (iii) where the ship is a double-ended ship, the distance measured from the aft side of the forward rudder stock to the foreside of the aft rudder stock, and (c) in the case of a ship that is not required to be registered pursuant to the Act, the horizontal distance measured between perpendiculars erected at the extreme outside ends of the hull; (longueur) liquefied petroleum gas means a liquefied inflammable gas that is composed predominantly of hydrocarbons or mixtures of hydrocarbons such as propane, propylene, butane, butylene or butadene, and that has a Reid vapour pressure exceeding 276 kPa absolute at 38° C; (gaz de pétrole liquéfié) local steering gear control system machinery spaces means machinery spaces of category A and all other spaces containing propelling machinery, steering gears, boilers, steam and internal combustion engines, generators and major electrical machinery, oil filling stations, refrigerating, stabilizing, ventilation and air-conditioning machinery, and similar spaces, and trunks to the spaces; (tranche des machines) machinery spaces of category A means (a) spaces that contain (i) internal combustion-type machinery used for main propulsion or, where the aggregate of total power output is not less than 373 kW, for purposes other than main propulsion, (ii) an oil-fired boiler, or (iii) a fuel oil unit, and (b) trunks to spaces referred to in paragraph (a); (tranche des machines de catégorie A) main steering gear means the main steering gear power unit and actuator by which torque is applied to the rudder stock for the purposes of effecting movement of the rudder to steer a ship; (appareil à gouverner principal) major repairs means repairs or alterations to machinery that substantially alter the capacity, size or type of the machinery; (réparations majeures) material test certificate means a certificate referred to in section 10; (certificat d’essai de matériau) periodic general inspection periodic special inspection pressure vessel remote steering gear control system means the system by which required rudder movements are transmitted to the steering gear power unit controls from the bridge or another location in a ship, excluding the steering gear compartment; (système de commande à distance de l’appareil à gouverner) rudder actuator means a unit transmitting torque to a rudder stock (a) through an externally connected tiller, quadrant or similar component, or (b) directly through an integrally housed vane or similar component; (actionneur de gouvernail) rules or codes means rules, regulations or codes relating to the construction, installation and inspection of marine machinery, issued by an approved classification society; (règles ou codes) shipside door-operating mechanism steering gear power unit means (a) in the case of an electric steering gear, an electric motor and its associated electrical arrangements, (b) in the case of an electro-hydraulic steering gear, an electric motor, and its associated electrical arrangements and the connected hydraulic pump, and (c) in the case of a hydraulic steering gear, the driving engine and connected hydraulic pump; (groupe moteur d’appareil à gouverner) test pressure means the maximum pressure to which the fluid in a component or system may be subjected during inspection; (pression d’essai) unfired pressure vessel means a container subjected to internal or external pressure, where the pressure is produced without the application of heat from an external source or by the application of heat from an indirect source or by any combination thereof, and includes condensers, evaporators, air receivers, hydro-pneumatic tanks, hydraulic accumulators, heat exchangers and similar components, but does not include cooling or heating spaces of engines, pumps, compressors, piping and similar components; (récipient sous pression non chauffé) windlass means the machinery and arrangements principally employed in the lowering and raising of the anchors of a ship, but does not include the anchors and cables. (guindeau) (2) The units of measurement used in these Regulations are as defined in the Metric Practice Guide published by the Canadian Standards Association. (3) Unless specifically stated otherwise, all prescribed pressures are gauge pressures. 3 (1) Subject to subsection (2), these Regulations apply in respect of every ship as defined in Part XV of the Act. (2) These Regulations do not apply in respect of a pleasure yacht or a non-passenger, non-self-propelled ship, except in respect of (a) propulsion system boilers on board a pleasure yacht, where the yacht is in excess of five tons gross tonnage; and (b) boilers and compressed air receivers on board a non-passenger, non-self-propelled ship carrying a crew where the ship (i) may operate or ply on voyages more than 15 miles from land, or (ii) does not operate or ply on voyages more than 15 miles from land and the boilers or compressed air receivers have an assigned working pressure in excess of 103 kPa. (3) Despite subsection (1), these Regulations do not apply in respect of vessels to which the Vessel Construction and Equipment Regulations apply. 4 (1) Any machinery referred to in Schedules I to XV that is constructed after the coming into force of these Regulations shall be constructed and installed in a ship in accordance with the following standards or specifications in force at the time the construction is commenced: (a) the standards or specifications in the rules or codes under which the machinery is being constructed; and (b) the design specifications set out in each item of Part I of the applicable schedule of Schedules I to XV and the general design specifications set out in Schedule XVI. (2) In the event of any inconsistency between the standards or specifications referred to in paragraph (1)(a) and the specifications referred to in paragraph (1)(b), the specifications referred to in paragraph (1)(b) shall prevail. (3) Any machinery referred to in subsection (1) that has been constructed in accordance with the standards or specifications in rules or codes of an approved classification society may be installed in a ship in accordance with the rules or codes of another approved classification society. 5 (1) Subject to subsection (2), major repairs to machinery referred to in Schedules I to XV that was constructed before or after the coming into force of these Regulations, including the reinstallation of components associated with the machinery following the major repairs, shall be made in accordance with the standards or specifications referred to in subsection 4(1) in force at the time the major repairs are commenced. (2) Where making major repairs in accordance with subsection (1) would be impracticable or inappropriate, the major repairs may be made in accordance with the standards or specifications relating to construction set out in the regulations in force at the time construction of the machinery commenced. 7 Specimen pieces of any material to be used in the construction of or repairs to machinery referred to in subsection 4(1) and required by the rules or codes under which the machinery is to be constructed to be tested prior to use shall be identified and shall, in the presence of an inspector, undergo, prior to the commencement of construction or repairs, the tests set out in those rules or codes. 8 (1) An inspector referred to in section 7 shall, prior to the commencement of a test, be provided with evidence that shows that all the material testing equipment to be used is in correct operational condition and adjustment. (2) The evidence referred to in subsection (1) may consist of current reports or certificates issued by an equipment testing organization that is accredited by the Standards Council of Canada. 9 On completion of the tests in the presence of an inspector, referred to in section 7, the material shall be permanently marked in the presence of that inspector with (a) the information on the material test certificate set out in Schedule XVII under the heading “MARKING — MARQUES”; and (b) the Federal Identity Symbol as printed on a stamp provided by the inspector. 10 An inspector shall issue a material test certificate in respect of a material in the form set out in Schedule XVII where (a) the specimen pieces of the material meet the test requirements set out in the rules or codes referred to in section 7; and (b) the material has been marked in accordance with section 9. 11 (1) Notwithstanding sections 7 and 9, an exclusive surveyor to an approved classification society or a metallurgist certified by a provincial government or by any other authority having similar certification standards may witness the tests and marking referred to in those sections. (2) Where an exclusive surveyor or metallurgist referred to in subsection (1) witnesses the tests and marking of a material, (a) the material test certificate shall include all testing information, bear the identification symbol of the employer of the exclusive surveyor or metallurgist and be signed by the exclusive surveyor or metallurgist; and (b) the permanent marking on the material shall include the identification symbol of the employer of the exclusive surveyor or metallurgist. 16 Subject to section 17, where an inspector has carried out a construction inspection of machinery in accordance with subsection 12(2), the inspector shall issue a component inspection certificate in the form set out in Schedule XVIII for each component of that machinery that is constructed in accordance with these Regulations. 17 Before issuing a component inspection certificate, an inspector shall ensure that the component is marked with the information on the certificate referred to in section 16 under the heading “MARKING — MARQUES”, including the Federal Identity Symbol. 18 (1) The marking referred to in section 17 shall be conspicuous and not readily effaced, covered or removed, and shall be located (a) in the case of a hot-water boiler or a steam boiler, adjacent to an access or visual inspection opening; (b) in the case of an unfired pressure vessel, on an end plate; (c) in the case of a shaft, on the flange rim; (d) in the case of a propeller, on the hub; and (e) in the case of any other component, adjacent to the manufacturer’s permanent identification marking. (2) Where a component cannot be marked on a location referred to in subsection (1) because marking on the location would be physically impossible or unsafe or the marking would not be readily visible, the inspector may accept another suitable location for the marking. SCHEDULE ISteam Boilers Having a Design Working Pressure Exceeding 350 kPa PART I(Section 4)Design SpecificationsItemRequirements1None. PARTS II to IV[Repealed, SOR/2021-135, s. 69] SCHEDULE IILow-Pressure Steam Boilers Having a Design Working Pressure Not Exceeding 350 kPa and Hot-Water Boilers Having a Design Working Pressure Not Exceeding 1 100 kPa or a Design Temperature Not Exceeding 120°C PART I(Section 4)Design SpecificationsItemRequirements1None. PARTS II to IV[Repealed, SOR/2021-135, s. 70] SCHEDULE IIIUnfired Pressure Vessels PART I(Section 4)Design SpecificationsItemRequirements1None. PARTS II to IV[Repealed, SOR/2021-135, s. 71] SCHEDULE IVReciprocating Engines PART I(Section 4)Design Specifications DIVISION IInternal Combustion Oil EnginesItemRequirements1None. DIVISION IISteam Reciprocating EnginesItemRequirements1None. PARTS II to IV[Repealed, SOR/2021-135, s. 72] SCHEDULE VTurbine Engines PART I(Section 4)Design Specifications DIVISION ISteam Turbine EnginesItemRequirements1None. DIVISION IIGas Turbine EnginesItemRequirements1None. PARTS II to IV[Repealed, SOR/2021-135, s. 73] SCHEDULE VIReversing and Reduction Gearing, Shafting Systems and Propellers PART I(Section 4)Design Specifications DIVISION IReversing and Reduction GearingItemRequirements1None. DIVISION IIShafting SystemsItemRequirements1Screw shafts shall be made of (a)carbon steel protected from exposure to water in the stern bearing by a corrosion-resistant continuous liner, or non-continuous liners between each of which is a welded joint or a suitable bonded coating; (b)carbon steel protected from exposure to water by means of an oil lubricated stern bearing with internal and external glands; (c)corrosion resistant metal in accordance with rules or codes; or (d)carbon steel not fitted with the methods of water exposure protection referred to in subitem (a) or (b). 2The screw shaft shall have the propeller attached by means of (a)a suitable shaft taper with a keyway that is (i)in sled runner form, or (ii)in a form where the top end is well rounded and smoothed off, with an adequate root radius; (b)a suitable shaft taper with no keyway; or (c)a coupling flange. DIVISION IIIPropellersItemRequirements1None. PARTS II to IV[Repealed, SOR/2021-135, s. 74] SCHEDULE VIISteering Systems, Shipside Components and Windlasses PART I(Section 4)Design Specifications DIVISION ISteering SystemsItemRequirements1A steering gear compartment shall (a)be readily accessible; (b)as far as practicable, be separated from propulsion machinery and auxiliary machinery spaces; and (c)be equipped with a means of communication with the bridge. 2All components and, in particular, non-duplicated essential components, shall be of sound and reliable construction, of adequate strength and protected against shock loading.3For essential components, bearings that are permanently lubricated or provided with lubrication fittings shall be utilized where required for the safe operation of the ship.4The pressure of the fluid for calculations to determine the scantlings of piping and steering gear components subjected to internal hydraulic pressure shall be at least 1.25 times the design working pressure under the operating conditions set out in item 9, taking into account any pressure that may exist in the low-pressure side of the system.5Where, due to dynamic loads on piping and steering gear components, pulsating pressures occur, the system design shall be such that fatigue does not cause material failure.6Relief valves shall be fitted to any part of the hydraulic system that can be isolated and in which pressure can be generated from the power source or from external forces.7Relief valve settings shall not exceed the design working pressure of the fluid set out in item 4 and the valves shall be of adequate size and arranged to avoid an undue rise in pressure above the design working pressure of the fluid.Steering Gears8Subject to items 19 and 20, the installation shall consist of totally independent main and auxiliary steering gears.9The main steering gear shall be designed, where the ship is at its deepest sea-going draft and (a)running ahead at maximum service speed, to put the rudder over (i)from 35 degrees on one side to 35 degrees on the other side, and (ii)from 35 degrees on either side to 30 degrees on the other side in not more than 28 seconds; and (b)running astern at maximum speed, for maximum rudder angle operation. 10A main steering gear shall be power-operated (a)where necessary to meet the requirements of item 9; and (b)where a rudder stock of over 120 mm in diameter, excluding strengthening for navigation in ice, is required at the position of tiller attachment. 11The auxiliary steering gear shall be designed, where the ship is at its deepest sea-going draft and running ahead one-half its maximum service speed or 7 knots, whichever is the greater, to put the rudder over from 15 degrees on one side to 15 degrees on the other side in not more than 60 seconds.12The auxiliary steering gear shall have the capacity to be brought safely and rapidly into action in an emergency.13An auxiliary steering gear shall be power-operated (a)where necessary to meet the requirements of item 11; and (b)where a rudder stock of over 230 mm in diameter, excluding strengthening for navigation in ice, is required at the position of tiller attachment. 14A power-operated auxiliary steering gear unit and its associated control system and rudder angle indicator shall, where the rudder stock is required to be over 230 mm in diameter, excluding strengthening for navigation in ice, be provided automatically with an alternative power source within 45 seconds of the failure of the main power source, from (a)the emergency electric power source; or (b)an independent power source located in the steering gear compartment that is used solely for that purpose. 15The alternative power source referred to in item 14 shall (a)in any ship of 10,000 tons gross tonnage or more be capable of at least 30 minutes continuous operation; and (b)in any other ship, be capable of at least 10 minutes continuous operation. 16Main and auxiliary steering gear power units shall be (a)capable of being brought into operation from a location on the bridge; (b)arranged to start automatically where power is restored after a power failure; and (c)equipped with an audible and visual alarm located on the bridge to indicate a power failure to any one power unit. 17Hydraulic power-operated main and auxiliary steering gears shall be equipped with the following: (a)arrangements to maintain the cleanliness of the hydraulic fluid, taking into consideration the type and design of the hydraulic system; (b)an audible and visual low-fluid-level alarm for each hydraulic fluid reservoir to give the bridge and the propulsion machinery space the earliest possible indication of hydraulic fluid leakage; (c)a fixed storage tank that has a contents gauge and sufficient capacity to refill the contents of at least one power-actuating system, including the reservoir, where the main steering gear is required to be power-operated; and (d)means by which the hydraulic systems can be readily and rapidly refilled from within the steering gear compartment through permanently connected piping leading from the storage tank. 18Electric and electrohydraulic power-operated main and auxiliary steering gears shall meet the following requirements: (a)means for indicating whether the motors of the electric or electrohydraulic steering gears are running shall be installed on the bridge and at a suitable propulsion machinery control location; (b)each electric or electrohydraulic steering gear comprising one or more power units shall be served by at least two exclusive circuits fed directly from the main switchboard, where one of the circuits may be supplied through the emergency switchboard; (c)an electric or electrohydraulic auxiliary steering gear associated with an electric or electrohydraulic main steering gear may be connected to one of the circuits supplying the main steering gear if the circuits have adequate rating for supplying all motors that can be simultaneously connected to them and that may be required to operate simultaneously; (d)short-circuit protection and an overload alarm shall be provided for the circuits and motors, and where protection against excess current including starting current is provided for a circuit or motor, the protection shall be not less than twice the full load current of the circuit or motor, as the case may be and shall be arranged to permit the passage of the appropriate starting currents; (e)where a three-phase power supply is used, an alarm shall be provided to indicate failure of any one of the supply phases and the alarm shall be audible, visual and situated (i)in a conspicuous location in the main machinery space or control room from which the main machinery is normally controlled, and (ii)as may be required by Schedule VIII; (f)where an auxiliary steering gear that is in a ship of less than 1,600 tons gross tonnage and that is required to be power-operated is not electrically powered or is powered by an electric motor primarily intended for other services, the main steering gear may be fed by one circuit from the main switchboard; and (g)where an electric motor primarily intended for other services is arranged to power an auxiliary steering gear in a ship of less than 1,600 tons gross tonnage, protection arrangements for electric and electrohydraulic power-operated steering gears are not required to meet the requirements set out in paragraphs (d) and (e) if suitable alternative arrangements are made. 19An auxiliary steering gear is not required where main steering gear power units and connections are fitted in duplicate if (a)for ships carrying more than 12 passengers, each steering gear power unit enables the steering gear to meet the requirements of item 9; (b)for ships carrying not more than 12 passengers, both steering gear power units operating together enable the steering gear to meet the requirements of item 9; and (c)for hydraulic-type steering gears, the main steering gear is arranged so that, after a single failure in its piping or in one of the steering gear power units, the defect can be isolated and steering capability can be maintained or rapidly regained, and for other types of steering gear, a similar standard can be achieved. 20An auxiliary steering gear is not required for double-ended ships with two independent steering systems, one fore and one aft, if in the case of failure of one of the steering systems the corresponding rudder can be safely and rapidly brought back to the centre line and kept steady in that position.21For every tanker, chemical tanker or gas carrier of 10,000 tons gross tonnage or more and every other ship of 70,000 tons gross tonnage or more, the main steering gear shall comprise two or more identical power units that meet the requirements of item 19.22Subject to item 23, every tanker, chemical tanker or gas carrier of 10,000 tons gross tonnage or more shall meet the following requirements: (a)the main steering gear shall be so arranged that in the event of loss of steering capability due to a single failure in any part of one of the power-actuating systems of the main steering gear, excluding the tiller, quadrant or components serving the same purpose or a seizure of the rudder actuators, steering capability shall be regained in less than 45 seconds after the loss of one power actuating system; (b)the main steering gear shall comprise (i)two independent and separate power-actuating systems, each capable of meeting the requirements of item 9, or (ii)at least two identical power-actuating systems that, acting simultaneously in normal operation, shall be capable of meeting the requirements of item 9 if (A)interconnection of hydraulic power-actuating systems, where necessary, is provided, and (B)loss of hydraulic fluid from one of the systems is capable of being detected and that system is automatically isolated so that the other system or systems remain fully operational; and (c)steering gears, other than of the hydraulic type, shall achieve a standard equivalent to the standard referred to in subitem (b). 23For tankers, chemical tankers or gas carriers of 10,000 tons gross tonnage or more, but of less than 100,000 tonnes deadweight, in the event of a single failure referred to in item 22 of a rudder actuator, the requirements set out in that item are not required to be met if (a)a safety standard equivalent to the standard set out in item 22 is achieved; (b)components meet the requirements of item 1 of Division II; (c)following loss of steering capability due to a single failure of any part of the piping system or in one of the power units, steering capability is regained within 45 seconds; and (d)where the steering gear includes only a single rudder actuator, the following factors are taken into special consideration in the actuator design and construction: (i)stress analyses including, as appropriate, fatigue analysis and fracture mechanics analysis, (ii)materials used, and (iii)hydraulic fluid sealing arrangements. DIVISION IINon-Duplicated Rudder Actuators for Tankers, Chemical Tankers and Gas Carriers of 10,000 Tons Gross Tonnage or more but less than 100,000 Tonnes DeadweightItemRequirements1Components that are subject to internal hydraulic pressure or that transmit mechanical forces to the rudder stock shall be made (a)of tested ductile materials in accordance with rules or codes; and (b)with pressure-retaining components that have a tensile strength of not more than 650 MPa and a percentage elongation of not less than 12 per cent. 2The design working pressure shall be at least equal to the greater of (a)1.25 times the maximum pressure expected under the operating conditions set out in subitem 9(a) of Division I; and (b)the relief valve pressure setting. 3In determining the scantlings of components of rudder actuators subject to internal hydraulic pressure, the following stresses are permitted: Sm shall not exceed f S1 shall not exceed 1.5f Sb shall not exceed 1.5f S1 + Sb shall not exceed 1.5f Sm + Sb shall not exceed 1.5f where Smis the equivalent primary general membrane stress S1is the equivalent primary local membrane stress Sbis the equivalent primary bending stress fis the lesser of SB/A or SY/B SBis the specified minimum tensile strength of material at ambient temperature Syis the specified minimum yield stress or 0.2 per cent proof stress of material at ambient temperature A and B are as follows: SteelCast SteelNodular Cast IronA44.65.8B22.33.5 4Pressure-retaining components not requiring fatigue analysis and fracture mechanics analysis in accordance with subitem 7(d) of Division I of Part II are acceptable on the basis of a certified burst test and in that case, the detailed stress analysis required by subitem 7(c) of Division I of Part II is not required.5The minimum bursting pressure shall be calculated as follows:Pb = P. A sBa/SB where Pbis the minimum bursting pressure Pis the design working pressure as set out in item 2 Ais the applicable value set out in the table to item 3 SBais the actual tensile strength SBis the tensile strength determined in accordance with item 3 6The construction shall minimize local concentrations of stress and all welded joints within the pressure boundary of a rudder actuator or connecting parts transmitting mechanical loads shall be of the full penetration type or of an equivalent strength.7Oil seals between non-moving components, forming part of the external pressure boundary, shall be of the metal-on-metal type or of an equivalent type.8Oil seals between moving components, forming part of the external pressure boundary, shall be duplicated, so that the failure of one seal does not render the actuator inoperative, or shall have sealing arrangements providing equivalent protection against leakage.9Isolating valves shall be fitted at the connection of pipes to the actuator and shall be directly mounted on the actuator.10Relief valves for protecting the rudder actuator against over-pressure as required by items 6 and 7 of Division I shall meet the following requirements: (a)the setting pressure shall not be less than 1.25 times the maximum pressure expected under the operating conditions set out in subitem 9(a) of Division I; (b)the minimum discharge capacity of the relief valves shall not be less than the total capacity of all pumps that provide power for the actuator, increased by 10 per cent; (c)under operating conditions the rise in pressure shall not exceed 10 per cent of the setting pressure; and (d)in respect of subitems (b) and (c), account shall be given to extreme foreseen ambient conditions in respect of oil viscosity. 11The rudder actuator shall be subjected to non-destructive testing in accordance with rules or codes to detect both surface flaws and volumetric flaws, and fracture mechanics analysis may be used for determining maximum allowable flaw size. DIVISION IIISteering ControlsItemRequirements1Steering-wheels or lever pointers shall (a)move to starboard to turn the bow of the ship to starboard; or (b)move to port to turn the bow of the ship to port. 2A rudder direction and angle indicator, independent of the remote steering gear control system, shall be fitted on the bridge where the main steering system is power-operated or the length of the ship exceeds 20 m.3Main steering gears shall be controllable from the bridge and from an alternative location in the steering gear compartment or other suitable location taking into account operational and risk factors.4A rudder angle indicator shall be fitted at the alternative location referred to in item 3.5Subject to item 6, two independent remote control systems, not including the steering-wheel or lever, shall be fitted where a duplicate main steering gear system is fitted.6Except in a tanker, chemical tanker or gas carrier of 10,000 tons gross tonnage or more a second independent control system is not required to be fitted where the control system is a hydraulic telemotor.7The auxiliary steering gear shall be controllable from the steering gear compartment and, if power-operated, shall be operable from the bridge and independent of the main steering gear control system.8Any main and auxiliary steering gear control system operable from the bridge shall meet the following requirements: (a)if electric, it shall be served by its own separate circuit supplied from a steering gear power circuit from a point within the steering gear compartment or directly from switchboard busbars supplying that steering gear power circuit at a point on the switchboard adjacent to the supply to the steering gear power circuit; (b)means shall be provided in the steering gear compartment for disconnecting any control system that is operable from the bridge to the steering gear it serves; (c)the system shall be capable of being brought into operation from a location on the bridge; (d)in the event of a failure of the electrical power supply to the control system, an audible and visual alarm shall be given on the bridge; and (e)short circuit protection only shall be provided for steering gear control supply circuits. 9Duplicate steering gear control systems, including pipes, electric power circuits and their components shall be separated, as far as practicable, throughout their length. DIVISION IVShipside ComponentsItemRequirements1For ships required to operate in ice-covered waters where ice may choke sea-water inlets, maintenance of essential sea-water supply shall be maintained by (a)diversion arrangements for warmed cooling water from overboard discharges into sea- water inlet boxes; (b)means to clear sea-water inlet boxes, preferably by steam that has a pressure not in excess of the design working pressure of the sea-water inlet boxes and that is vented to the upper deck by means of a valved pipe; and (c)ensuring sea-water inlet strainers have (i)perforations approximately 20 mm in diameter to prevent ingestion of large ice particles, and (ii)a strainer perforated area approximately 5 times the total cross-sectional area of the inlet pipes being served to ensure full fluid flow in slush ice conditions. DIVISION VWindlassesItemRequirements1None. PARTS II to IV[Repealed, SOR/2021-135, s. 75] SCHEDULE VIIIRemote Control and Monitoring Systems in Periodically Unattended Machinery Spaces PART I(Section 4)Design Specifications DIVISION IApplicationItemDescription of Ships1In this schedule,Group 1 ship means a ship in which machinery is controlled and monitored from the bridge and engineers do not maintain surveillance watch duties in the machinery spaces and that is certificated for the following voyages: (a)Foreign voyage, Home Trade Class I or II or Inland Waters Class I; or (b)Home Trade Class III or IV, Inland Waters Class II or Minor Waters where the propulsion total brake power of the ship exceeds 2000 kW; Group 2 ship means a ship in which machinery may be controlled from the bridge and at least one engineer is on watch in a remote central control room location only and that is certificated for the following voyages: (a)Foreign voyage, Home Trade Class I or II or Inland Waters Class I; or (b)Home Trade Class III or IV, Inland Waters Class II or Minor Waters where the propulsion total brake power of the ship exceeds 2000 kW; Group 3 ship means a ship (a)that has main propulsion and ship service reciprocating type-internal combustion engines; (b)in which machinery is controlled and monitored from the bridge or a central control room; (c)that is certificated for Home Trade voyages Class III or IV, Inland Waters Class II or Minor Waters voyages where the propulsion total brake power of the ship does not exceed 2000 kW; and (d)in which engineering personnel do not maintain surveillance watch duties within the machinery space. 2This Schedule does not apply to Group 1, 2 or 3 ships that are (a)passenger ships; (b)non-passenger ships fitted with a remote machinery control location, which may be the bridge, where (i)the machinery space is continuously manned by an engineer maintaining surveillance watch duties who is capable of locally controlling the machinery, and (ii)bridge-to-machinery-space telegraphic and telephonic communication systems are fitted; and (c)non-passenger ships fitted with a machinery control location in a room within, or immediately adjacent to, the machinery space where (i)engineering personnel maintain regular surveillance watch duties within the machinery space, and (ii)an audible and visual alarm system provides a means to alert engineering personnel to return to the control location room. DIVISION IIGroup 1, 2 and 3 ShipsItemRequirements1Remote and automatic control and monitoring of machinery located in periodically unattended spaces shall offer the same level of safety from remote control locations as would be obtained if the machinery were arranged for continuous local manual control and monitoring by watchkeeping engineers.2Control, monitoring and safety devices and their location shall meet the requirements set out in rules or codes in respect of ship motion, structural vibration and atmospheric environment.3Every enclosed central control location shall have two means of access located remote from each other, except where such enclosures are so small that two means of access are impracticable.4Two sources of power to ensure continuous operation shall be provided for control, monitoring and alarm systems, and (a)where electrical power is used, (i)the systems shall be served by at least two exclusive circuits fed directly from the main switchboard, and one of the circuits shall be supplied through the emergency switchboard, where fitted, and these circuits shall not supply power for any other machinery, and (ii)a main-line disconnect or circuit-breaker for all console power shall be provided in a readily accessible location; (b)where pneumatic power is used, each source shall consist of an air compressor, separately supplied with power, and an air receiver, both of adequate capacity and arranged to allow cross connection or isolation; and (c)where hydraulic power is used, these sources shall be separate from any other hydraulic service requirements and each hydraulic pump shall be separately supplied with power. 5Failure of control, monitoring and alarm systems or their power supply shall activate an audible and visual alarm at the central control location.6An audible and visual alarm system shall be provided to indicate any fault requiring attention and shall (a)be capable of sounding an audible alarm in the main machinery control room or at the propulsion machinery remote control location and of indicating each separate alarm function visually at a suitable location; (b)be connected to the engineers’ public rooms and to each of the engineers’ cabins through a selector switch that connects to at least one of the cabins at all times; (c)activate an audible and visual alarm on the bridge for any situation that requires action by or the attention of the officer on watch; (d)as far as practicable, be designed to have fail safe characteristics; and (e)activate the alarm in the engineers’ public rooms and cabins if an alarm has not received attention locally within a set time. 7The alarm system shall be equipped to indicate at the same time more than one fault and the acceptance of an alarm shall not inhibit another alarm.8Acceptance at either of the locations referred to in subitem 6(a) of an alarm shall be indicated at the location where the alarm was activated.9An audible alarm shall sound until it is accepted and the visual indication of the alarm shall remain until the fault has been corrected, after which the alarm system shall automatically reset to the normal operating condition.10Machinery controls shall be designed to remain accurate throughout the operating range and to have fail safe characteristics.11Machinery controls shall be robust and easy to operate, not cause undue stress in systems being controlled and operate in a logical direction and sequence with a detent at the stop or neutral position.12A safety system shall be provided to ensure that a serious malfunction in boiler and other machinery operations that presents an immediate danger initiates the automatic shut-down of the boiler or other machinery and activates an alarm, except that shut-down of the propulsion system shall only be automatically activated in cases that could lead to serious damage, complete breakdown or explosion.13Where arrangements for overriding the shut-down of the main propelling machinery are fitted, the arrangements shall be such as to preclude inadvertent operation, and visual means shall be provided to indicate when the override has been activated.14Remote-controlled machinery systems and periodically unattended machinery spaces shall be equipped as follows: (a)a fire detection and alarm system shall be fitted that is capable of providing coverage (i)throughout the machinery spaces, and (ii)in boiler air supply and exhaust casings and internal combustion engine scavenge air belts on ships of 500 tons gross tonnage or more, where the casings and air belts are prone to fire; (b)fire detection and alarm systems shall be used and the location of scanners and types of detectors shall be based on the heat and smoke hazards involved and the required sensitivity of operation; (c)a fire control system with associated equipment shall be fitted in all machinery spaces to provide firefighting capability in accordance with (i)the Vessel Fire Safety Regulations, in the case of vessels in respect of which those Regulations apply, or (ii)the Fire Detection and Extinguishing Equipment Regulations, as they read immediately before being repealed, in any other case; (d)the remote fire control system shall be operable from an accessible location outside the machinery spaces; (e)the fire control location shall have instructions posted and all arrangements necessary for the operation of the system including, where applicable, stopping of machinery and fans, closing of valves, starting of remote fire pumps and release of smothering gas; (f)guards shall be provided to prevent leakage of oil from fuel oil systems from dripping or spraying onto hot surfaces; and (g)a fuel leakage collector system leading to a collector tank and fitted with an alarm to indicate leakage shall be fitted except where surveillance is required in accordance with item 67 of Subdivision II of Division IV for ships exempted from carrying watchkeeping engineers. 15A reliable means of voice communication shall be provided between the main machinery control location or propulsion machinery control location and the bridge, the engineers’ cabins and the engineers’ public rooms.16Propulsion machinery orders from the bridge shall be indicated in the main machinery control room or at the propulsion machinery control station.17Manuals for the proper operation and maintenance of remote control and monitoring systems, containing all necessary information for normal and emergency operation and maintenance shall be provided aboard ship.18Testing procedure manuals for remote control and monitoring systems shall be provided aboard ship and the testing procedures shall (a)contain step-by-step or check-off stages and not impair the operation of the installed alarms and safety devices after testing under simulated fault conditions has been completed; (b)specify the frequency of testing, indicate the tools required to complete the testing and the location of the tools in the systems; and (c)be concise but sufficiently explicit to allow engineering personnel to carry out the testing and interpret the results. DIVISION IIIGroup 1 and 2 ShipsItemRequirementsMachinery1Internal combustion engines of 2250 kW or more or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors, engine-bearing temperature monitors or equivalent devices.2Where internal combustion engines are used for main propulsion, means shall be provided to keep the starting air pressure at the level required to start the engine.3The number of consecutive automatic attempts that fail to start an engine shall be limited in order to safeguard sufficient starting air pressure and an audible alarm set at a level that permits starting of the propulsion machinery shall be provided to indicate low starting air pressure.4The main source of electrical power shall meet the following requirements: (a)where the electrical power can under normal conditions be supplied by one generator, suitable load-shedding arrangements shall be provided to safeguard the supplies of power needed by propulsion, steering and safety systems; and (b)except where impracticable for ships of less than 1,600 tons gross tonnage, in the case of failure of the operating generator, adequate provision shall be made for automatic starting and connecting to the main switchboard of a stand-by generator of sufficient capacity to permit, in sequential operation where necessary, automatic restarting of the essential propulsion, steering and safety systems. 5Where electrical power is supplied simultaneously by more than one generator in parallel operation, provision shall be made in case of failure of one of the operating generator sets to keep the remaining generator sets in operation without overload to permit propulsion and steering, and to ensure the safety of the ship.6Where stand-by machines are necessary for the operation of other auxiliary machinery essential to propulsion, automatic change-over devices shall be fitted.Controls and Alarms7Under all operating conditions the speed, direction of thrust and, where applicable, the pitch of the propeller shall be fully controllable by remote control from the bridge.8The remote control shall be operated by a single control device for each independent propeller with automatic performance of all associated services without causing overload of the propulsion machinery.9The main propulsion machinery shall be equipped with an emergency stopping device on the bridge that is independent of the bridge control system.10The control system shall be such that the services needed for the operation of the main propulsion machinery and its auxiliaries are performed automatically.11An audible and visual alarm shall be activated when the automatic change-over of the control power source is activated.12An alarm system that meets the requirements of items 7 to 9 of Division II shall be provided for all pressures, temperatures, fluid levels and other data essential to the safe operation of the ship.13A centralized control location shall be arranged with the necessary alarm panels and instrumentation to indicate that an alarm has been activated.14Remote control of the propulsion machinery shall be possible only from one location at a time and inter-connected control positions are permitted at each location.15At each location there shall be an indicator showing which location is in control of the propulsion machinery and the transfer of control between the bridge and machinery spaces shall be possible only in the main machinery space or in the machinery control room.16The control system shall include means to prevent, when the system transfers control from one location to another, the propelling thrust from altering to the extent that control of the ship is endangered.17All machinery essential for the safe operation of the ship shall be capable of being controlled locally.18The design of the remote automatic control system shall be such that an alarm is given on failure of the system and, unless impracticable, the preset speed and direction of thrust of the propeller is maintained until local control is in operation.19Indicators shall be fitted on the bridge for (a)propeller speed and direction of rotation in the case of fixed-pitch propellers; or (b)propeller speed and pitch position in the case of controllable-pitch propellers. 20Bilge wells in periodically unattended machinery spaces shall be located and monitored in such a way that the accumulation of liquids is detected at normal angles of trim and heel, and shall be large enough to easily accommodate normal drainage during an unattended period.21Where the bilge pumps are capable of being started automatically, visual and audible alarms shall be provided to indicate when the influx of liquid is greater than the pump capacity or when the pump is operating more frequently than would be expected under normal conditions.22Where automatic bilge pumps are fitted, (a)an audible and visual alarm and shut-down arrangement shall be fitted in the system to operate in the event of oil being detected and the shut-down arrangement shall have an emergency manual override capability; and (b)valves that are open on dry bilges shall be automatically closed so that there is no loss of suction in bilge suction systems. 23The position of the controls of any valve serving a sea inlet, a discharge below the water-line or a bilge injection system shall be located to allow adequate time for operation of the controls in case of an influx of water to the space, having regard to the time likely to be required to reach and operate the controls.24Arrangements shall be made to operate the controls from a position above the level to which the unattended space might become flooded when the ship is fully loaded. DIVISION IVGroup 3 Ships SUBDIVISION IItemApplication1In this Division, the bridge control station includes the wheelhouse, its top and wings. SUBDIVISION IIItemRequirementsMain and Auxiliary Machinery Controls1Control locations shall have a visual indicator to show when they are in command and the central control location shall have monitors and alarms in accordance with items 65 and 66.2The machinery control arrangement shall be such that only one location can be in control at any one time, and with the exception of the override capability referred to in item 8, transfer of control from the central control location to local control shall not be possible until the receiving location has indicated its readiness to accept the intended transfer.3All essential machinery shall be capable of being fully operated locally when remote or automatic control systems are not operating.4Transfer to local control of machinery shall be easily and rapidly accomplished and any material or tools required to effect the transfer shall be permanently located at a convenient location adjacent to the machinery.5Where an engine is arranged to start automatically or by remote control, interlocks shall be provided to prevent starting of the engine under conditions that could be hazardous to the machinery, which conditions shall include turning gear engaged, low lubricating-oil pressure and, where applicable, shaft brake engaged.6Where an internal combustion engine is arranged to start automatically, the number of consecutive automatic attempts to start the engine without success shall be limited in order to safeguard sufficient starting air pressure or in the case of electric starting, sufficient battery power, for local attempts to start the engine.Main Propulsion Systems7Means shall be provided at the central control location and locally at the engines themselves to stop the main propulsion engines in an emergency and the emergency stopping devices shall be independent of the normal control system and adequately protected against accidental damage or operation.8Local control of the main propulsion engines shall have capability of overriding the remote control systems and there shall be an audible and visual alarm to alert the locations affected by an override in accordance with subitem 65(a)(i).9For ships of not more than 150 tons gross tonnage remote propulsion engine controls are not required to be power-operated and are not required to be in duplicate.10Prolonged running of a main propulsion engine in a restricted speed range shall be prevented automatically or an indication of restricted speed ranges shall be posted at each control location.Steering Systems11In the event of failure of the main steering system there shall be an auxiliary system capable of being brought into operation from the central control location within 45 seconds.Electrical Power Systems12In the event of failure of the electrical generator supplying ship service power where generated electrical energy is required for essential service, there shall be a stand-by generator capable of assuming all essential electrical load and, for ships in excess of 150 tons gross tonnage, the stand-by generator shall be arranged to assume the load automatically within 45 seconds.Boilers and Hot-Air Heating Units13Steam and hot-water boilers, hot-air heating units and associated systems shall be capable of automatic operation and of meeting requirements within design limitations under all working conditions.14Automatic operation shall include, as applicable, controls and monitors for fuel flow and temperature, combustion air flow, burner flame, feed-water flow, feed-water contamination by salt or oil, boiler pressure and hot-air heating unit circulating air flow.15The control and monitoring equipment shall be designed to prevent unsafe operation of the boiler or hot-air heating unit.16Any failure of control and monitoring equipment shall prevent continued operation of the boiler or hot-air heating unit and cause the fuel supply to be cut off and an audible and visual alarm to be activated in accordance with subitem 65(e).17A master fuel oil shut-off valve shall be fitted in the fuel supply line and shall close automatically in the event of (a)loss of flame; (b)inadequate air to support combustion; (c)abnormally high steam or water pressure in boilers; (d)loss of circulating fluid in hot-water boilers and hot-air heating units; or (e)water at a low level in steam boilers. 18A fuel oil shut-off valve shall be fitted to each burner in the fuel supply line and the valve shall close automatically in the case of flame failure or whenever the automatic program requires that the master fuel oil shut-off valve be closed.19Automatic combustion controls shall be fitted to provide an adequate fuel-to-air ratio throughout the operational range.20Where the system is designed to light the initial burner automatically or from a remote location, purging of the combustion chamber and convection spaces shall automatically take place for a period that is sufficient to ensure at least four changes of air, which period shall last at least 15 seconds.21Adequate air flow and the correct position of the air registers and dampers shall be indicated before the purging period starts.22Fuel oil may be ignited by an electrical spark generated by a transformer having an output of not less than 10,000 volts, a glow plug or a light-oil pilot flame that has been electrically ignited.23A means of ignition system described in item 22 shall be provided for burners that are automatically or remote controlled.24The electrical ignition system shall be energized before or simultaneously with the introduction of fuel or light oil and shall remain energized during the trial-for-ignition period referred to in item 25.25Where fuel or light oil is electrically ignited, the flame safeguard control system shall provide a trial-for-ignition period of not more than 15 seconds, during which fuel or light oil may be introduced to the ignition source and, if a flame is not established within 15 seconds, the oil supply valve shall close automatically.26Where fuel oil is ignited by a light-oil pilot flame, the flame safeguard control shall provide a trial-for-ignition period of not more than 15 seconds, during which fuel oil may be introduced to the pilot flame and if a fuel oil flame is not established within 15 seconds the fuel oil supply valve to the pilot flame shall close automatically.27Fuel oil shall not be supplied to a burner before the light-oil pilot flame has been confirmed.28Flame safeguard controls of the thermostatic type operated by means of an open bi-metallic helix shall not be used.29A flame safeguard control shall be provided to each burner so that the fuel oil supply valve can be closed in not more than four seconds in the event of flame failure and the master fuel oil shut-off valve can be closed in the event of flame failure at all burners.30The failure of a component in the flame safeguard control shall cause a shut-down of the burner and the design of the control shall prevent automatic restarting.31The flame safeguard control shall be fitted with an audible and visual alarm in the event of flame failure and the control shall require resetting for restart purposes.32A low-fire interlock shall be fitted to a multi-burner boiler so that the lowest burner is ignited first, and the other burners shall not be ignited until the scanner indicates that there is a flame in the lowest burner.Steam Boilers33Automatically operated steam boilers shall be fitted with water-level controls and low water-level limit controls.34Water-level controls and low water-level limit controls may be of the float, electrode probe, thermostatic expansion tube or thermo-hydraulic type.35Water-level controls and low water-level limit controls shall be located to minimize the effect of the roll and pitch of the ship.36The low water-level limit control shall close the master fuel oil shut-off valve when the water level falls to a minimum safe level visible in the gauge glass and the system may include a five-second time delay to avoid shut-down due to the rolling and pitching of the ship.37After operation of the low water-level limit control, manual resetting of the control shall be required before the boiler burners can be re-lit.38Float-operated water-level and low water-level limit controls shall be so constructed that they will not be damaged by water levels above or below the operating range.39The low water-level limit control shall have independent connections to the boiler.40Water-level controls shall be so constructed that the water inlet valve cannot feed water into the boiler through the float chamber.41No outlet connection shall be placed on (a)the water-level control float chamber; (b)the low water-level limit control float chamber; or (c)pipes connecting the float chambers to the boiler. 42For controls that are external to the boiler drum, the connections shall be fitted with shut-off valves locked and sealed in the open position and attached directly to the boiler drum.Auxiliary Systems43Subject to item 44, pumps and other components essential for main propulsion engine operation shall have stand-by pumps and components, and for ships of more than 150 tons gross tonnage, the stand-by pumps and components shall be arranged to start up automatically on failure of the operating pumps or other components.44In multi-engined ships where engines have integral pumps, a spare pump readily available for installation may be used in lieu of an automatic-starting stand-by pump.45Air compressors, refrigeration systems and other ship service systems that are essentially independent and self-controlled need not be controlled from a remote control location.46Bilge water high-level audible and visual alarms shall be fitted at the central control location in accordance with subitem 65(f)(vi) and shall monitor the following bilges: (a)aft port and starboard sides of each machinery space of category A; and (b)any bilge aft of the collision bulkhead on ships certificated for towing operations. 47The bilge pumping systems shall be arranged to function for a reasonable period after the sounding of the bilge high-level alarm taking into account the size of the space bilges.48Where automatic bilge pumps are fitted (a)an audible and visual alarm and shut-down arrangements shall be fitted in the system to operate in the event of oil being detected and the s

    The text continues in the official source.

    Related guides, FAQ and contract templates