    SOR-2025-88:en — Reduction in the Release of Volatile Organic Compounds (Storage and Loading of Volatile Petroleum Liquids) Regulations

    Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.

    Analyze this law with AI
    1 (1) The following definitions apply in these Regulations. Act means the Canadian Environmental Protection Act, 1999. (Loi) ASTM means ASTM International, formerly known as the American Society for Testing and Materials. (ASTM) authorized official means (a) in respect of an operator that is a corporation, an officer of the corporation who is authorized to act on its behalf; (b) in respect of an operator that is an entity other than a corporation, an individual who is authorized to act on its behalf; and (c) in respect of an operator who is an individual, that individual or another individual who is authorized to act on their behalf. It includes a person who has been designated in writing as a delegate to an officer or individual referred to in paragraph (a), (b) or (c), as the case may be, as well as a person who has been appointed to a position in replacement of such a person. (agent autorisé) design specifications means documents and records relating to any equipment, instrument or monitoring device that establish how the equipment, instrument or monitoring device must be manufactured, constructed, used or maintained to achieve its intended function and level of performance, including technical data, engineering drawings, standards, material specifications, manufacturer specifications, commissioning checklists, data sheets, manuals and standard operating procedures. (spécifications de conception) emissions control equipment means any type of equipment – including a vapour control system, temporary vapour control system, internal floating roof or external floating roof or pressure-vacuum vent, as well as alternative emissions control equipment referred to in section 80 – that is used to limit VOC emissions from tanks and loading racks. (équipement de contrôle des émissions) existing tank means a tank that is in service on or before the day on which these Regulations come into force. (réservoir existant) existing loading rack means a loading rack that is in service on or before the day on which these Regulations come into force. (rampe de chargement existante) existing vapour control system means a vapour control system that is under construction or in service at the facility on or before the day on which these Regulations come into force. (système de contrôle des vapeurs existant) external floating roof means a floating roof that is installed in a tank without a fixed roof such that the upper surface of the floating roof is exposed to atmospheric conditions. (toit flottant externe) facility means any buildings, other structures and stationary equipment that are used in the storage or loading of volatile petroleum liquid and located on a single property or on several properties that have at least one operator in common, are connected by piping that transfers volatile petroleum liquid and are separated by a property boundary to property boundary distance of no more than 2 km. (installation) fenceline monitoring program means, (a) a standard, modified or alternative fenceline monitoring program that meets the requirements of the Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector); (b) a fenceline monitoring program in accordance with section 60 of the Petrochemical - Industry Standard issued under Ontario Regulation 419/05 (Air Pollution – Local Air Quality); or (c) a fenceline monitoring program that meets all the requirements of the following methods published by the United States Environmental Protection Agency: (i) Method 325A — Volatile Organic Compounds from Fugitive and Area Sources: Sampler Deployment and VOC Sample Collection, except that the sampling period may range between 13 and 15 days, and (ii) Method 325B — Volatile Organic Compounds from Fugitive and Area Sources: Sampler Preparation and Analysis, except that all samples must be analyzed for benzene. (programme de surveillance du périmètre) fixed roof means a roof that is permanently attached to a tank. (toit fixe) fixed roof tank means a tank that is equipped with a fixed roof but is not equipped with an internal floating roof. (réservoir à toit fixe) flare means any type of combustion device without an enclosed combustion chamber, including a burn pit designed to burn liquids or mixtures of gases and liquids. (torchère) floating roof means a structure that floats on the surface of a liquid and whose purpose is to limit vapour loss of that liquid to the environment. (toit flottant) gasoline means (a) a fuel that is sold or represented as gasoline with a benzene concentration of less than or equal to 1.5% by volume; or (b) a petroleum distillate, or a mixture of petroleum distillates, oxygenates or additives, that is suitable for use in a spark ignition engine and has the following characteristics, as determined using the applicable test method listed in the National Standard of Canada standard CAN/CGSB-3.5-2021 entitled Automotive gasoline: (i) a vapour pressure of at least 35 kPa, (ii) an antiknock index of at least 80, (iii) a distillation temperature at which 10% of the fuel has evaporated of not less than 35°C and not greater than 70°C, (iv) a distillation temperature at which 50% of the fuel has evaporated of not less than 60°C and not greater than 120°C, and (v) a benzene concentration of less than or equal to 1.5% by volume. (essence) guide pole means a structure that is placed in a tank equipped with a floating roof for the purpose of preventing the floating roof from rotating within the tank or for the purpose of monitoring or sampling the liquid inside the tank. (poteau de guidage) high benzene loading rack means a loading rack that is designated under paragraph 13(a) or used to load a volatile petroleum liquid with a benzene concentration greater than 20% by weight. (rampe de chargement de liquide à haute concentration en benzène) high benzene tank means a tank that is designated under paragraph 12(a) or contains a volatile petroleum liquid with a benzene concentration greater than 20% by weight. (réservoir de liquide à haute concentration en benzène) inerted tank means a tank that opens to the atmosphere only through a pressure-vacuum vent and that is supplied with a non-hydrocarbon inert gas such that the atmosphere inside the tank contains insufficient oxygen to support combustion. (réservoir inerté) internal floating roof means a floating roof that is installed in a tank with a fixed roof such that the upper surface of the floating roof is protected from atmospheric conditions. (toit flottant interne) liquid means any type of liquid, including volatile petroleum liquid. (liquide) liquid leak means a leak for which three drops of liquid per minute or more form at the source as measured from the average number of drops per minute observed visually over a period of three minutes. (fuite de liquide) loading means any transfer of a liquid into a vehicle tank or from a vehicle tank into a fixed roof tank. (chargement) loading factor means a numerical value that represents the level of VOC emissions from a loading rack. (facteur de chargement) loading rack means all of the stationary equipment used for loading liquids, including structures, loading arms, pumps, piping and instrumentation. (rampe de chargement) lower explosive limit or LEL means the lowest concentration of a combustible vapour in the air that may ignite at a given temperature and pressure. (limite inférieure d’explosivité ou LIE) lower explosive limit percentage or LEL% means the ratio of the observed concentration of a combustible vapour to the LEL of that vapour, expressed as a percentage. (pourcentage de la limite inférieure d’explosivité ou pourcentage LIE) occupied building means a structure located outside of a facility’s property boundary that is used as a residence, workplace, place of education, medical establishment, childcare establishment or social or community centre, including a mobile home or portable building, but does not include (a) other mobile structures such as a tent, trailer or houseboat; (b) structures in which persons are present for less than one hour per day; or (c) structures whose initial construction began after the day on which these Regulations first applied to the facility. (bâtiment occupé) operator, in respect of a facility, means (a) if there is one person who operates, has charge of, manages or controls the facility, that person; (b) if there is more than one person who operates, has charge of, manages or controls the facility, the person who, under a written agreement between all those persons, is designated to be the operator; and (c) if the persons referred to in paragraphs (a) and (b) cannot be identified, the owner of the facility. (exploitant) petroleum means (a) naturally occurring hydrocarbons, such as natural gas, natural gas condensate, crude oil or bitumen; (b) hydrocarbon derivatives of the substances referred to in paragraph (a), such as fuels, lubricating oils, petrochemicals or asphalt; (c) coal tar and coal tar distillates; or (d) synthetic or semi-synthetic analogues of the substances referred to in paragraphs (a) to (c). (pétrole) petroleum processing equipment means equipment that is used to physically or chemically separate, transform or modify petroleum, including a distillation column, reactor or coker, but does not include equipment used only for storing, handling or blending petroleum, such as a tank, loading rack, pump or pipeline. (équipement de traitement du pétrole) population centre means a population centre — as defined by Statistics Canada in its publication entitled Dictionary, Census of Population, 2021 — with a population greater than 20,000. (centre de population) pressure-vacuum vent means a device that permits the flow of gas to or from the environment in the event of excess pressure or vacuum inside a fixed roof tank.(évent à pression-dépression) primary seal means, as the case may be, (a) on a floating roof that has two or more rim seals, the rim seal that is mounted closest to the surface of the liquid; or (b) on a tank that has only one rim seal, that rim seal. (joint primaire) qualified professional means a scientist or technologist who specializes in an applied science or technology applicable to their duty or function, such as engineering, engineering technology or chemistry. (professionnel qualifié) scheduled maintenance means maintenance of equipment that is scheduled to be performed on or before a date known to the operator of a facility in order to (a) comply with the design specifications of the equipment; (b) adhere to a schedule or project plan established by the operator in respect of the equipment; or (c) ensure that the equipment complies with a regulatory requirement. (entretien prévu) secondary seal means any rim seal mounted above the primary seal on a floating roof that has two or more rim seals. (joint secondaire) standard m3, in respect of the volume of a fluid, means cubic metres, when the fluid’s volume is measured at a temperature of 15°C and an absolute pressure of 101.325 kPa. (m3 normalisé) switch loading means the loading of a liquid that is not a volatile petroleum liquid into a vehicle tank that previously contained a volatile petroleum liquid without, before the liquid is loaded, the vapours in the vehicle tank being purged to a vapour control system or the vehicle tank being washed with a liquid that is not a volatile petroleum liquid. (chargement en alternance) tank means a tank, vessel, reservoir or container that is used to contain liquids, regardless of its shape or material of construction, but does not include (a) a vessel that operates under pressure or as part of a closed system such that there are no expected releases to the environment while the vessel is operating under normal operating conditions, including when it is being filled or emptied and when ambient conditions are changing; or (b) a cavern, underground porous rock reservoir or geological formation where liquids are stored under pressure. (réservoir) temporary vapour control system means a vapour recovery system or vapour destruction system designed for temporary or mobile use. (système temporaire de contrôle des vapeurs) vapour means any vapour or gas containing VOCs, including vapour arising from volatile petroleum liquid. (vapeur) vapour balancing system means a vapour control system that conveys vapours displaced during loading operations from the receiving tank to the source tank and prevents them from being released to the environment. (système de retour en boucle des vapeurs) vapour control system means a system that is designed to capture all vapours emitted from tanks or during loading operations and prevent them from being released to the environment. (système de contrôle des vapeurs) vapour destruction system means a vapour control system that destroys vapours by combustion, thermal oxidation or other means, including systems in which vapours are combusted to produce useful heat or energy and systems in which vapours are combusted for the sole purpose of preventing their release to the environment. (système de destruction des vapeurs) vapour leak means any release of vapour other than a release for which the concentration of VOCs at the source is determined, using a portable monitoring instrument, to be less than (a) 10 000 parts per million by volume, if the release is detected on or before December 31, 2026; or (b) 1000 parts per million by volume, if the release is detected after December 31, 2026. (fuite de vapeur) vapour pressure means the absolute partial pressure exerted on the walls of a vessel containing a liquid by the gas molecules above that liquid, when the liquid and its vapour are in equilibrium. (pression de vapeur) vapour recovery system means a vapour control system that captures vapours for a use other than their immediate use to produce heat or energy at a facility, including a non-regenerative system that retains the vapours in a solid or liquid medium. (système de récupération des vapeurs) vehicle means a machine that is designed to be mobile, including a truck, railcar, ship, transport barge or trailer but is not designed or has not been modified to serve for the purposes of the permanent stationary storage of liquids. (véhicule) vehicle tank means a tank attached to or integrated into a vehicle, other than a tank that is exclusively used to supply fuel to the vehicle’s engine. (réservoir de véhicule) vehicle-to-vehicle loading means the loading of volatile petroleum liquids directly from one vehicle tank to another without the use of a loading rack. (chargement de véhicule à véhicule) volatile organic compound or VOC means a compound that participates in atmospheric photochemical reactions that is not excluded under item 60 of Part 2 of Schedule 1 to the Act. (composé organique volatil ou COV) volatile petroleum liquid means petroleum, or a mixture that contains petroleum, that (a) exists as a liquid at a temperature of 20°C and an absolute pressure of 101.325 kPa; (b) contains 10% or more volatile organic compounds by weight; (c) has a vapour pressure greater than 10 kPa or, if the benzene concentration is greater than 2% by weight, 3.5 kPa; and (d) is not a mixture of petroleum and ethanol that contains less than 10% petroleum by weight. (liquide pétrolier volatil) (2) Any document that is incorporated by reference in these Regulations is incorporated as amended from time to time. (3) In the event of an inconsistency between a provision in a document incorporated by reference into these Regulations and any provision of these Regulations, the provision of these Regulations prevails to the extent of the inconsistency. 2 (1) Subject to subsection (2), these Regulations apply to any facility that meets any of the following conditions: (a) the sum of the internal volume of all tanks at the facility that are used to store volatile petroleum liquids is greater than or equal to 500 m3; (b) the total volume of volatile petroleum liquid loaded at the facility exceeds 4000 standard m3 in a calendar year; (c) at least one tank at the facility has an internal volume greater than or equal to 5 m3 and is used to store a volatile petroleum liquid with a benzene concentration greater than 20% by weight; or (d) at least one tank at the facility has an internal volume greater than or equal to or greater than 100 m3and is used to store a volatile petroleum liquid with a vapour pressure greater than 76 kPa. (2) These Regulations do not apply to the following facilities: (a) facilities where volatile petroleum liquids are stored or loaded exclusively for the purposes of retail fuel sales at the facilities; (b) facilities that extract petroleum from an underground geological deposit or reservoir; (c) facilities that perform primary processing of petroleum after its extraction from an underground geological deposit or reservoir to (i) remove water, carbon dioxide, sulphur compounds or contaminants from the petroleum, or (ii) separate the petroleum into gaseous and liquid streams; (d) facilities that store or load petroleum before it undergoes primary processing at a facility referred to in paragraph (c); (e) facilities that separate a petroleum feed into its individual components or fractions, if at least 90% by weight of the petroleum feed entering the facility exists as a vapour at a temperature of 20°C and an absolute pressure of 101.325 kPa; (f) offshore facilities that are located more than three nautical miles from shore; (g) facilities whose property boundary is located more than 100 km from any population centre, if (i) the loading racks at the facility are never used to load volatile petroleum liquids with a benzene concentration greater than 2% by weight, (ii) the sum of the internal volume of all tanks at the facility that are used to store volatile petroleum liquids is less than 10 000 m3, (iii) the total volume of volatile petroleum liquid loaded at the facility does not exceed 30 000 standard m3 in a calendar year, and (iv) the total volume of volatile petroleum liquids loaded at the facility does not exceed 2000 standard m3 in a day; (h) facilities where each tank used to store volatile petroleum liquids and each loading rack used to load volatile petroleum liquids is located more than 300 m from any occupied building, if (i) the tanks at the facility are never used to store, and the loading racks at the facility are never used to load, volatile petroleum liquids with a vapour pressure greater than 76 kPa or a benzene concentration greater than 2% by weight, (ii) the sum of the internal volume of all tanks at the facility that are used to store volatile petroleum liquids is less than 2000 m3, (iii) the total volume of volatile petroleum liquid loaded at the facility does not exceed 25 000 standard m3 in a calendar year, and (iv) the total volume of volatile petroleum liquid loaded at the facility does not exceed 500 standard m3 in a day; and (i) facilities where each tank used to store volatile petroleum liquids and each loading rack used to load volatile petroleum liquids is located more than 60 m from any occupied building, if (i) the tanks at the facility are never used to store, and the loading racks at the facility are never used to load, volatile petroleum liquids with a vapour pressure greater than 76 kPa or a benzene concentration greater than 2% by weight, (ii) the sum of the internal volume of all tanks at the facility that are used to store volatile petroleum liquids is less than 2000 m3, (iii) the total volume of volatile petroleum liquid loaded at the facility does not exceed 20 000 standard m3 in a calendar year, (iv) the total volume of volatile petroleum liquid loaded at the facility does not exceed 500 standard m3 in a day, and (v) the volatile petroleum liquids are stored at the facility in either fixed roof tanks that are each less than 5 m in diameter and 150 m3 in volume or underground tanks of any size. 3 For greater certainty, these Regulations apply to facilities that engage in the upgrading — by means involving distillation — of crude oil or bitumen, or of crude oil or bitumen that has been blended with other hydrocarbon compounds. 4 (1) For the purposes of these Regulations, the distance between a tank or loading rack and an occupied building is the shortest distance between any part of the tank or loading rack that could be a source of VOC emissions and the perimeter of the occupied building. (2) For the purposes of these Regulations, the distance between a facility and a population center is the shortest distance between the property boundary of the facility and the boundary of the population centre. 5 (1) These Regulations apply to all tanks and loading racks at a facility other than (a) tanks with an internal volume of less than 5 m3; (b) tanks with an internal volume of less than 50 m3 that are never used to store gasoline or volatile petroleum liquids with a vapour pressure greater than 76 kPa or a benzene concentration greater than 2% by weight. (c) tanks that are attached to or integrated into a vehicle; and (d) tanks and loading racks that are subject to the Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector) and are equipped with a vapour control system that meets the requirements of those Regulations or, if those Regulations do not apply as a result of an agreement made under subsection 10(3) of the Act, a vapour control system that meets the requirements of the provisions referred to in that agreement. (2) If a tank or loading rack is exempted under subsection (1), the internal volume of the tank, or the volume of volatile petroleum liquid loaded with the loading rack, is not to be taken into account when determining, under subsection 2(1), whether these Regulations apply to the facility. 6 (1) The operator of a facility must ensure that all tanks, loading racks and emissions control equipment at the facility are assigned identifiers. (2) The operator must ensure that the identifiers are (a) marked on the tanks, loading racks and, if accessible to the operator, emissions control equipment; (b) recorded in asset management tools or electronic programs that are used to track inventory and maintenance of equipment; and (c) indicated on a site plan such that all tanks, loading racks and emissions control equipment can be identified at any time. (3) The operator must ensure that each instrument used for the purposes of these Regulations is marked with an identifier. 7 (1) A tank is (a) considered to be in service during any period in which it is used to store a volatile petroleum liquid; (b) considered to be not in service during any period in which it is not used to store a volatile petroleum liquid and, if it was previously in service, if it meets one of the conditions set out in subsection (2); and (c) considered to be not in service if the tank was emptied of all volatile petroleum liquids before the day on which these Regulations come into force and has not been used to store volatile petroleum liquids since it was emptied. (2) A tank that was previously in service is considered to be not in service if (a) the interior of the tank has been cleaned to remove all volatile petroleum liquid, any sludge and any solid petroleum materials and the value of the LEL% inside the tank is less than 10 in the absence of mechanical ventilation; or (b) a liquid other than a volatile petroleum liquid has been introduced into the tank and (i) testing of the liquid inside the tank indicates that it is not a volatile petroleum liquid, and (ii) the value of the LEL% inside the tank is less than 10 in the absence of mechanical ventilation. 8 A loading rack is (a) considered to be in service during any period in which it is used to load a volatile petroleum liquid or is used for switch loading; and (b) considered to be not in service during any period in which it is not used to load any volatile petroleum liquid and is not used for switch loading. 9 A vapour control system is (a) considered to be in service beginning on the day on which it is first used at a facility; and (b) considered to be not in service during any period in which its operation is interrupted in accordance with subsection 56(2). 10 (1) Subject to subsection (2), an operator may use up to three tanks at a single facility as intermittent service tanks. However, none of those tanks may be in service for more than 300 hours per calendar year. (2) The operator must not use a high benzene tank, or a tank designated as a high volatility liquid tank under paragraph 12(b), as an intermittent service tank. (3) For the purposes of subsection (1), if the properties of the liquid contained in a tank vary such that the liquid is considered to be a volatile petroleum liquid at certain times, the operator must ensure that a statistical or engineering analysis is conducted to demonstrate that the tank will be in service for 300 hours or less per calendar year. (4) A tank that is used as an intermittent service tank is exempt from the requirements set out in sections 39 and 40. 11 (1) Subject to subsection (2), an operator may use a tank as a surge tank if it is used only for the temporary storage of liquids transferred from a pipeline or petroleum processing equipment under abnormal operating conditions. (2) The operator must not use a high benzene tank as a surge tank. (3) The operator must remove any liquid transferred into a tank that is used as a surge tank as soon after the transfer as the circumstances permit. (4) A tank that is used as a surge tank is exempt from the requirements set out in sections 39 and 40. 12 The operator of a facility must designate each tank that is in service at the facility as belonging to one of the following categories: (a) high benzene tank, in which case the tank may contain any volatile petroleum liquid; (b) high volatility liquid tank, in which case the tank may only contain a volatile petroleum liquid whose benzene concentration does not exceed 20% by weight; (c) volatile petroleum liquid tank, in which case the tank may only contain a volatile petroleum liquid whose vapour pressure does not exceed 76 kPa and benzene concentration does not exceed 20% by weight; or (d) small volatile petroleum liquid tank, in which case the tank (i) must have an internal volume of less than 150 m3 or, if the tank is in the form of a vertically oriented cylinder capable of accommodating a floating roof, an internal diameter of less than 5 m, and (ii) may only contain a volatile petroleum liquid whose vapour pressure does not exceed 76 kPa and benzene concentration does not exceed 20% by weight. 13 The operator of a facility must designate each loading rack that is used at the facility to load volatile petroleum liquids as belonging to one of the following categories: (a) high benzene loading rack, in which case the loading rack may be used to load any volatile petroleum liquid; (b) volatile petroleum liquid loading rack, in which case the loading rack may only be used to load a volatile petroleum liquid whose benzene concentration does not exceed 20% by weight; (c) low throughput loading rack, in which case the loading rack may only be used to load a volatile petroleum liquid if the benzene concentration does not exceed 20% by weight and if either (i) the loading rack and any fixed roof tank that receives volatile petroleum liquid from the loading rack are located more than 300 m from any occupied building and the following loading factors do not exceed 1: (A) the total loading factor of the facility, and (B) the maximum daily loading factor of the facility, or (ii) the loading rack is located more than 50 km from any population centre and more than 1.5 km from any occupied building and the following loading factors do not exceed 2: (A) the total loading factor of the facility and (B) the maximum daily loading factor of the facility, or (iii) the loading factor of the loading rack does not exceed 0.04; or (d) remote loading rack, in which case the loading rack may only be used to load a volatile petroleum liquid if the vapour pressure of that liquid does not exceed 76 kPa, the benzene concentration of that liquid does not exceed 0.5% by weight and the loading rack is located more than 50 km from any population centre and more than 1.5 km from any occupied building. 14 An operator must designate the category of a tank or loading rack by recording the designation in the inventory established under section 108 and indicating the category in the records maintained under section 110 or 112, as applicable. 15 (1) The internal volume of a tank is the sum of the volumes of each space inside the tank that may be occupied by a volatile petroleum liquid. (2) Two or more tanks connected by a shared space or piping through which vapour may flow and that is not kept closed or isolated under normal operating conditions are considered to be a single tank with an internal volume equal to the sum of the internal volumes of the tanks and the internal volume of the shared space or piping. (3) If a compartment of a tank is sealed to prevent entry of vapour and liquid from elsewhere in the tank, that compartment is considered to be a separate tank with a separate internal volume. (4) The internal volume of a tank that is equipped with an internal floating roof or external floating roof or that has a variable internal volume must be calculated at the highest design liquid fill level of the tank. 16 (1) The loading factor, the total loading factor and the maximum daily loading factor of a facility must be calculated in accordance with Schedule 1. (2) If an authorized official determines that the volume of volatile petroleum liquids loaded with a loading rack was increased temporarily due to an exceptional event that was not the result of scheduled maintenance that is under the control of the operator and determines that the operator minimized the duration and increase in volume loaded during the event to the extent possible, the calculation of the loading factor may be modified in accordance with item 1(c)(iv) of Schedule 1. 17 (1) The operator of a facility must reduce the frequency of vehicle-to-vehicle loading at the facility to a minimum. (2) The operator must ensure that vehicle-to-vehicle loading is performed in a safe location as far away as possible from occupied buildings. 18 The operator must ensure that sampling and testing conducted for the purposes of these Regulations are conducted in accordance with sections 19 to 29. 19 (1) For the purposes of these Regulations, VOC concentration, vapour pressure or benzene concentration of a liquid with multiple immiscible phases is the highest value of the VOC concentration, vapour pressure or benzene concentration of any single immiscible phase of the liquid. (2) If it is impossible to determine the value referred to in subsection (1), one of the following samples must be used: (a) if an immiscible phase is not present in a large enough quantity to form a separate layer from another more abundant phase, a well-mixed sample of both phases together; or (b) if an immiscible phase forms a stable emulsion in another phase and a sample of the pure phase cannot be obtained, a sample of the emulsion. 20 For the purposes of these Regulations, all gasoline is considered to have a VOC concentration of 100% by weight, a vapour pressure of 65 kPa and a benzene concentration of 1% by weight. 21 (1) If the applicable test methods referred to in sections 23 to 25 or an accepted alternative test method includes methods for sampling liquids, an operator must use one of those sampling methods. (2) If the applicable test methods referred to in sections 23 to 25 or an accepted alternative test method do not include a method for sampling liquids, the sampling of liquids must be performed in accordance with one of the following sampling methods: (a) the method set out in the standard ASTM D3700–21, entitled Standard Practice for Obtaining LPG Samples Using a Floating Piston Cylinder; (b) the method set out in the standard ASTM D8009–22, entitled Standard Practice for Manual Piston Cylinder Sampling for Volatile Crude Oils, Condensates, and Liquid Petroleum Products; or (c) the method set out in standard ASTM D4057–22, entitled Standard Practice for Manual Sampling of Petroleum and Petroleum Products. (3) Despite subsection (2), the sampling of crude oil, natural gas condensate and other naturally occurring petroleum and the sampling of other liquids that are known or suspected to contain hydrocarbon components that exist as a vapour under ambient conditions must be performed in accordance with the method referred to in paragraph (2)(a). (4) Despite subsections (2) and (3), if the pressure at the sampling point is insufficient to permit sample collection, the sampling must be performed in accordance with the method referred to in paragraph (2)(b). (5) Despite subsections (2), (3) and (4), if the liquid is too viscous to permit sample collection, the sampling must be performed in accordance with the method referred to in paragraph (2)(c). (6) Sample containers must remain sealed after the sample is collected and may be opened only for testing in accordance with the applicable testing method. 22 All sampling must be performed by one of the following persons: (a) a qualified professional; (b) a person supervised by a qualified professional; or (c) a person who has, not more than 12 months before the first time that they perform sampling, received training on the relevant sampling methods for the purposes of these Regulations from a qualified professional. 23 (1) The vapour pressure of a liquid must be determined in accordance with one of the following test methods: (a) the method ASTM D2879–23, entitled Standard Test Method for Vapor Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope; or (b) the method ASTM D6377–20, entitled Standard Test Method for Determination of Vapor Pressure of Crude Oil: VPCRx (Expansion Method). (2) The test method referred to in paragraph (1)(a) may be used only to measure the vapour pressure of a liquid that consists of a single chemical species or of a single chemical species with an amount of impurities that is acceptable for general commercial trade. (3) A vapour-liquid ratio of 4:1 must be used to determine the vapour pressure of a liquid in accordance with the test method referred to in paragraph (1)(b). (4) The following temperatures must be used to determine the vapour pressure of a liquid in accordance with one of the test methods referred to in subsection (1): (a) if the liquid is at ambient temperature, 20°C; and (b) if the liquid is artificially heated or cooled, the highest monthly average operating temperature observed during the preceding 12 months. 24 The benzene concentration of a liquid must be determined in accordance with one of the following test methods: (a) the method ASTM D3606–24a, entitled Standard Test Method for Determination of Benzene and Toluene in Spark Ignition Fuels by Gas Chromatography; (b) the method ASTM D4367–22, entitled Standard Test Method for Benzene in Hydrocarbon Solvents by Gas Chromatography; (c) the method ASTM D5134–21, entitled Standard Test Method for Detailed Analysis of Petroleum Naphthas through n-Nonane by Capillary Gas Chromatography; (d) the method ASTM D5580–21, entitled Standard Test Method for Determination of Benzene, Toluene, Ethylbenzene, p/m-Xylene, o-Xylene, C9 and Heavier Aromatics, and Total Aromatics in Finished Gasoline by Gas Chromatography; (e) the method ASTM D5769–22, entitled Standard Test Method for Determination of Benzene, Toluene, and Total Aromatics in Finished Gasolines by Gas Chromatography/Mass Spectrometry; (f) the method ASTM D6229–06, entitled Standard Test Method for Trace Benzene in Hydrocarbon Solvents by Capillary Gas Chromatography; (g) the method ASTM D7504–23, entitled Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number; or (h) the method National Standard of Canada CAN/CGSB-3.0 No. 14.3-2022, entitled Methods of testing petroleum and associated products: Standard test method for the identification of components in automotive gasoline using gas chromatography. 25 (1) Subject to subsection (2), the VOC concentration of a liquid must be determined in accordance with one of the following test methods: (a) the method set out in the standard ASTM E169–16, entitled Standard Practices for General Techniques of Ultraviolet-Visible Quantitative Analysis; or (b) the method set out in the standard ASTM E260–96, entitled Standard Practice for Packed Column Gas Chromatography. (2) If the liquid is an oil-water mixture, its VOC concentration may be determined by any method that conforms to generally accepted engineering practices, including a method that involves the use of physical simulation or the application of standards or supplier specifications. 26 (1) An instrument used to determine the presence of VOCs in vapour form, including for the purpose of detecting vapour leaks, must be of one of the following types: (a) a portable monitoring instrument that meets the requirements set out in subsection 5(1) of the Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector); (b) an optical gas-imaging instrument that meets the requirements set out in subsections 5(2) and (3) of those Regulations; or (c) a combustible gas detector that uses a catalytic bead sensor and meets the requirements set out in section 28 of these Regulations. (2) An instrument used to determine an LEL% must be of the type referred to in paragraph (1)(a) or (c). (3) An instrument used to determine whether a release of a vapour is a vapour leak must be of the type referred to in paragraph (1)(a). (4) If an LEL% is calculated from a measurement obtained with a portable monitoring instrument that produces a result in units of volume concentration, a VOC concentration of 140 parts per million by volume is considered to equal an LEL% of 1. 27 Any instrument referred to in these Regulations must be used and calibrated in accordance with its design specifications. 28 (1) A combustible gas detector that uses a catalytic bead sensor must meet the following requirements: (a) each day before it is used, it must be calibrated in accordance with its design specifications using output correction factors, if necessary, and a calibration gas that are appropriate for the expected vapour composition; (b) it must produce an output directly as an LEL%; (c) it must have an output range that spans an LEL% of at least 1 to 100; and (d) it must have an output accuracy that is within plus or minus 5% of a reading or plus or minus LEL% of 2, whichever value is greater, when used with the expected vapour composition. (2) A combustible gas detector that uses a catalytic bead sensor must not be used in the following environments: (a) an atmosphere that contains less than 10% oxygen by volume; (b) an atmosphere that contains substances that are likely to poison the catalyst; or (c) any other environment in which, according to the design specifications of the combustible gas detector, the detector may not provide an accurate output. 29 All testing required under sections 23 to 25 must be performed by one of the following persons: (a) a qualified professional; (b) a person supervised by a qualified professional; or (c) a person who has, not more than 12 months before the first time that they perform testing, received training from a qualified professional on the testing methods that are relevant for the purposes of these Regulations. 30 (1) An operator may apply to the Minister to use an alternative test method to those required under sections 23 to 25 for one of the following purposes: (a) to test a substance with properties that fall outside the scope of applicability of the required test methods; (b) to perform automated or continuous testing that cannot be accomplished using any of the required test methods; or (c) to achieve accuracy or precision that is superior to that of one of the required test methods. (2) The alternative test method must (a) measure the same physical properties as one of the test methods required under sections 23 to 25; and (b) for all cases in which it would be used, be equivalent or superior to, including in precision and accuracy, one of the test methods required under sections 23 to 25. (3) For the purposes of paragraph (2)(b), the operator must determine the equivalency of the alternative test method in accordance with one of the following test methods: (a) the method set out in the standard ASTM D3764–23, entitled Standard Practice for Validation of the Performance of Process Stream Analyzer Systems; or (b) the method set out in the standard ASTM D6708–24, entitled Standard Practice for Statistical Assessment and Improvement of Expected Agreement Between Two Test Methods that Purport to Measure the Same Property of a Material. (4) The application must be submitted at least 60 days before the day on which the alternative test method is to be used. (5) The application must contain the information referred to in Schedule 2 and may be submitted in respect of more than one of the operator’s facilities. (6) The Minister may, on receiving the application, require that the applicant provide any clarifications or additional information that is necessary for the Minister to consider the application. 31 (1) If the Minister determines that the alternative test method meets the conditions set out in subsection 30(2), the Minister may accept the use of the alternative test method and must notify the applicant in writing of the decision, of any conditions of use of the method and of the situations in which the use of the method is permitted. (2) The applicant may begin using the alternative test method only after receipt of the notice of acceptance from the Minister. (3) An operator whose application to use an alternative test method has been accepted must maintain all records and supporting documents relating to the application. (4) The Minister must reject the application and must notify the applicant of that decision if (a) the Minister determines that the alternative test method does not meet the conditions set out in subsection 30(2); or (b) the information required under subsection 30(5) has not been provided or is insufficient to enable the Minister to consider the application. 32 (1) The Minister may publish a list of accepted alternative test methods, including the conditions of use of the methods and the situations in which their use is permitted. (2) An operator may use an accepted alternative test method that is on the list published under subsection (1) and, if they do so, they must maintain records and any supporting documents that demonstrate that the conditions for the use of the accepted alternative test method have been met. 33 (1) The operator of a facility must ensure that any tank at the facility that must be designated under section 12 and any loading rack at the facility that must be designated under section 13 is equipped with emissions control equipment in accordance with the requirements set out in sections 38 to 42, as applicable. (2) The operator must ensure that the emissions control equipment meets the requirements with respect to design and operation set out in sections 50 to 79 and the requirements with respect to inspection, testing and repair set out in sections 86 to 106, as applicable. (3) Despite subsection (2), if a tank designated under section 12 is equipped with a vapour control system and an internal floating roof, the operator is not required to ensure that the internal floating roof meets the applicable requirements referred to in subsection (2). 34 (1) Despite subsections 33(1) and (2), during a period when a tank or loading rack is not in service, sections 38 to 42 and 50 to 79 do not apply to that tank or loading rack. (2) During a period when a tank or loading rack is not in service, an operator may delay or omit the inspections referred to in sections 86 and 91, subsection 93(1) and sections 94 to 96 and 104, the tests referred to in sections 87 to 89 and the measurement referred to in section 97 until 30 days after the tank or loading rack is returned to service. (3) Despite any repair timelines established in sections 100, 101, 105 and 106, an operator must repair defects that are present when the tank or loading rack is not in service before the tank or loading rack is returned to service. 35 The operator of a facility must ensure that the emissions control equipment at the facility is operated, maintained, inspected and repaired only by a person who has, not more than 12 months before the first time that they operate, maintain, inspect or repair the emissions control equipment, received training on (a) the safe operation, maintenance and calibration of the emissions control equipment and, if applicable, leak detection instruments; and (b) the applicable requirements of these Regulations. 36 The operator of a facility may use a flare as a vapour control system only if it meets one of the following conditions: (a) the flare is in service at the facility before the day on which these Regulations come into force, or under construction on that day, and is used to control emissions from a tank that is not a high benzene tank or loading rack that is not a high benzene loading rack; or (b) the flare is used only for limited periods to receive excess vapours when flowrates exceed the capacity of the primary vapour control system or the primary vapour control system is inoperative. 37 The operator of a facility must ensure that each tank at the facility is designed, operated and maintained in a manner that allows for the effective operation of the emissions control equipment that is installed on that tank. 38 Subject to section 44, the operator of a facility must ensure that each tank at the facility that is a high benzene tank or is designated as a high volatility liquid tank under paragraph 12(b) is equipped with a vapour recovery system or vapour destruction system. 39 The operator of a facility must ensure that each tank at the facility that is designated as a volatile petroleum liquid tank under paragraph 12(c) is equipped with at least one of the following: (a) a vapour recovery system; (b) a vapour destruction system; (c) an internal floating roof; or (d) an external floating roof. 40 The operator of a facility must ensure that each tank at the facility that is designated as a small volatile petroleum liquid tank under paragraph 12(d) is equipped with at least one of the following: (a) a vapour recovery system; (b) a vapour destruction system; (c) an internal floating roof; (d) an external floating roof; or (e) a pressure-vacuum vent. 41 An operator must ensure that the liquid inlet of a tank designated under section 12 is positioned such that liquid enters the tank no more than 15 cm above the bottom of the tank unless (a) the tank is equipped with a vapour control system; (b) the liquid level in the tank always remains above the inlet during normal operation; or (c) the tank is an existing tank. 42 The operator of a facility must ensure that each loading rack at the facility that is a high benzene loading rack or is designated as a volatile petroleum liquid loading rack under paragraph 13(b) is equipped with one of the following vapour control systems: (a) a vapour recovery system, a vapour destruction system or a vapour balancing system, in the case of a loading rack at a facility where all volatile petroleum liquids loaded, are fuels that are stored either in fixed roof tanks that each have an internal volume of less than 150 m3 or, if the tanks are in the form of a vertically oriented cylinder capable of accommodating a floating roof, an internal diameter of less than 5 m, or in underground tanks of any size; (b) a vapour recovery system, in the case of a loading rack that is used to load gasoline to trucks at a facility where more than 250 000 standard m3 per year of gasoline is loaded per calendar year and that was not equipped with an existing vapour destruction system on the day on which these Regulations came into force; and (c) a vapour recovery system or vapour destruction system, in any other case. 43 (1) An operator may use a temporary vapour control system on a tank or loading rack instead of the emissions control equipment required under section 38, 39, 40 or 42, as the case may be, during the following time periods: (a) if the requirements set out in those sections do not, under sections 135 and 136, apply to the tank or the loading rack on the day on which these Regulations come into force, or if the tank or loading rack has been designated as a deferred application tank or loading rack under section 125, a period not exceeding one year beginning on the day on which section 38, 39, 40 or 42 begins to apply to the tank or loading rack; (b) if the emissions control equipment requires scheduled maintenance or is to be replaced, a period not exceeding 180 days; (c) if a defect of the emissions control equipment is detected and the temporary vapour control system is used under paragraph 90(1)(b) or 101(2)(b), a period not exceeding one year; (d) if a defect of the emissions control equipment is detected and the temporary vapour control system is used under paragraph 100(1)(b), for the repair period referred to in that paragraph; and (e) in the case of a tank, the period during which the tank’s interior is being cleaned or the tank is being emptied until the tank is no longer in service. (2) If the requirements of subsection 53(2) and section 57 are met with respect to the temporary vapour control system, the operator may use it for an indefinite period instead of the applicable period referred to in any of paragraphs (1)(a) to (d). (3) An operator must use a temporary vapour control system during the following periods: (a) the period during which any of the activities referred to in paragraphs 49(1)(a) to (c) are being carried out, if the high benzene tank in question has not been equipped with a vapour control system or its vapour control system is inoperable; (b) the period during which a vapour control system that is being used to control emissions from a high benzene tank is inoperable due to scheduled maintenance; and (c) the period during which a vapour control system that is being used to control emissions from a high benzene loading rack is inoperable and that loading rack is being used to load a volatile petroleum liquid with a benzene concentration greater than 20% by weight. 44 (1) Subject to subsections (2) and (3), the operator of a facility may continue to use an internal floating roof or external floating roof instead of a vapour control system to control VOC emissions from any existing high benzene tank at the facility that contained a liquid with a benzene concentration greater than 20% by weight on the day on which these Regulations come into force or during the period of one year that precedes that day if (a) the tank is located more than 300 m from any occupied building; (b) the tank is equipped with an internal floating roof or external floating roof that was installed before the day on which these Regulations come into force and that is free from the defects referred to in paragraphs 100(5)(d) and 101(1)(a); and (c) the operator of the facility has established a fenceline monitoring program at the facility, the benzene concentration measured at every sampling location of the fenceline monitoring program is less than or equal to the values set out in subsection 45(1) and the arithmetic average of the benzene concentration measured at every sampling location of the fenceline monitoring program in respect of that facility is less than or equal to the applicable value set out in subsection 45(2). (2) Subsection (1) ceases to apply in respect of existing high benzene tanks equipped with external floating roofs on the seventh anniversary of the day on which these Regulations come into force. (3) Subsection (1) does not apply in respect of existing high benzene tanks located at a facility that was subject to the Interim Order Respecting Releases of Benzene from Petrochemical Facilities in Sarnia, Ontario, made by the Minister on May 16, 2024 and published in Part 1 of the Canada Gazette on May 21, 2024. 45 (1) For the purposes of paragraph 44(1)(c), the benzene concentrations measured in at least 24 of the 26 most recent sampling periods must be less than or equal to the following values: (a) in the case of a sampling period that ends before the first anniversary of the day on which these Regulations come into force, 19 μg/m3; (b) in the case of a sampling period that ends on or after the first anniversary of the day on which these Regulations come into force but before the second anniversary of that day, 17 µg/m3; (c) in the case of a sampling period that ends on or after the second anniversary of the day on which these Regulations come into force but before the third anniversary of that day, 15 µg/m3; and (d) in the case of a sampling period that ends on or after the third anniversary of the day on which these Regulations come into force, 13 µg/m3. (2) For the purposes of paragraph 44(1)(c), the arithmetic average of the benzene concentrations measured for the 26 most recent sampling periods must be less than or equal to the following values: (a) if the most recent sampling period ends before the first anniversary of the day on which these Regulations come into force, 6.5 µg/m3; (b) if the most recent sampling period ends on or after the first anniversary of the day on which these Regulations come into force but before the second anniversary of that day, 5.5 µg/m3; (c) if the most recent sampling period ends on or after the second anniversary of the day on which these Regulations come into force but before the third anniversary of that day, 4.5 µg/m3; and (d) if the most recent sampling period ends on or after the third anniversary of the day on which these Regulations come into force, 3.5 µg/m3. (3) For the purposes of paragraph 44(1)(c), the operator must exclude data collected during (a) sampling periods that ended before the ones for which data is included in the report submitted to the Minister under subsection 47(2); (b) sampling periods that ended before the day on which the operator equipped an existing high benzene tank at the facility with a vapour control system in accordance with section 38 and the first two sampling periods that ended after that day, if the arithmetic average of the benzene concentrations measured at every sampling location of the fenceline monitoring program in respect of that facility for the third to the eighth sampling periods that ended after that day was less than or equal to the following values: (i) if the eighth sampling period ends before the first anniversary of the day on which these Regulations come into force, 6.5 µg/m3; (ii) if the eighth sampling period ends on or after the first anniversary of the day on which these Regulations come into force but before the second anniversary of that day, 5.5 µg/m3; (iii) if the eighth sampling period ends on or after the second anniversary of the day on which these Regulations come into force but before the third anniversary of that day, 4.5 µg/m3; and (iv) if the eighth sampling period ends on or after the third anniversary of the day on which these Regulations come into force, 3.5 µg/m3; and (c) sampling periods that the Minister indicated under subsection 48(2) must be excluded. (4) When calculating the arithmetic average referred to in subsection (2), if the operator excludes data under subsection (3), the benzene concentration measured for each excluded sampling period at every sampling location must be replaced by the applicable value set out in paragraphs (2)(a) to (d) for the year in which the most recent included sampling period ended. (5) For the purposes of subsections (1) and (2) and section 47, if the benzene concentration in a sample is less than the method detection limit, the method detection limit is considered to be the value of the benzene concentration in the sample. 46 (1) If a condition set out in paragraph 44(1)(a) or (b) is no longer met with respect to an existing high benzene tank at a facility, the operator of the facility must ensure that that tank meets the requirements of section 38 within one year after the day on which the condition was no longer met. (2) If the conditions set out in paragraph 44(1)(c) are no longer met with respect to a facility, the operator of the facility must reduce by one the number of existing high benzene tanks at the facility for which an internal floating roof or external floating roof is used instead of a vapour control system, within one year after the day on which the condition was no longer met. (3) If the conditions set out in paragraph 44(1)(c) are still not met at the end of the one-year period referred to in subsection (2), the operator must reduce by two the number of existing high benzene tanks at the facility for which an internal floating roof or external floating roof is used instead of a vapour control system each subsequent year until either (a) the conditions set out in paragraph 44(1)(c) are met; or (b) all existing high benzene tanks at the facility meet the requirements of section 38. 47 (1) An operator of a facility that, under section 44, continues to use an internal floating roof or external floating roof instead of a vapour control system at a facility to control VOC emissions, must submit reports to the Minister in accordance with subsections (2) and (4). (2) The operator must submit to the Minister, no later than 180 days after the day on which these Regulations come into force, a first report that contains data for a minimum of 6 and a maximum of 26 of the most recent consecutive sampling periods and contains the information referred to in Part 1 of Schedule 3. (3) Despite subsection (2), if the operator established a fenceline monitoring program at the facility under the Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector) before the day on which these Regulations come into force, the operator is not required to include the information referred to in items 6 to 8 of Part 1 of Schedule 3 in the first report. (4) The operator must submit to the Minister, no later than 30 days after each anniversary of the day on which these Regulations come into force, an annual report that contains data for all of the sampling periods for which analytical results are available that began after the last sampling period for which data was included in the preceding report and that contains the information referred to in items 1 to 4 and 9 of Part 1 of Schedule 3 and any updates to the information referred to in items 5 to 8 of that Part. (5) Despite subsection (4), if the operator established a fenceline monitoring program at the facility under the Reduction in the Release of Volatile Organic Compounds Regulations (Petroleum Sector) before the day on which these Regulations come into force, the operator is not required to include updates to the information referred to in items 5 to 8 in Part 1 of Schedule 3 in the annual report. 48 (1) An operator that, under section 44, continues to use an internal floating roof or external floating roof instead of a vapour control system to control VOC emissions, must notify the Minister if any benzene concentration measured under the fenceline monitoring program exceeds the applicable value set out in paragraphs 45(1)(a) to (d) or results i

    The text continues in the official source.

    Related guides, FAQ and contract templates