SOR-2012-167:en — Reduction of Carbon Dioxide Emissions from Coal-fired Generation of Electricity Regulations
Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.
Analyze this law with AI1 (1) These Regulations establish a regime for the reduction of carbon dioxide (CO2) emissions that result from the production of electricity by means of thermal energy using coal as a fuel, whether in conjunction with other fuels or not.
(2) These Regulations are divided into four Parts as follows:
(a) Part 1 sets out a performance standard for the intensity of CO2 emissions from regulated units and provides for exceptions based on the substitution of units and for temporary exemptions in relation to emergencies and units integrated with carbon capture and storage systems;
(b) Part 2 sets out requirements for the reporting, sending, recording and retention of information;
(c) Part 3 sets out quantification rules for determining the intensity of CO2 emissions from regulated units; and
(d) Part 4 provides dates for the coming into force of these Regulations and, in particular, delays the coming into force of the performance standard in respect of standby units until January 1, 2030.
2 (1) The following definitions apply in these Regulations.
Act means the Canadian Environmental Protection Act, 1999. (Loi)
ASTM means ASTM International, formerly known as the American Society for Testing and Materials. (ASTM)
auditor means a person who
(a) is independent of the responsible person who is to be audited; and
(b) has demonstrated knowledge of and experience in
(i) the certification, operation and relative accuracy test audit (RATA) of continuous emission monitoring systems, and
(ii) quality assurance and quality control procedures in relation to those systems. (vérificateur)
authorized official means
(a) in respect of a responsible person that is a corporation, an officer of the corporation who is authorized to act on its behalf;
(b) in respect of a responsible person that is an individual, that person or a person authorized to act on that individual’s behalf; and
(c) in respect of a responsible person that is another entity, a person authorized to act on that other entity’s behalf. (agent autorisé)
biomass means a fuel that consists only of non-fossilized, biodegradable organic material that originates from plants or animals but does not come from a geological formation, and includes gases and liquids recovered from organic waste. (biomasse)
calendar year
capacity factor, in respect of a unit in a calendar year, means the ratio of the quantity of electricity referred to in section 19 that is produced by the unit to the quantity of electricity that would be produced by the unit in the calendar year if it were to operate at its production capacity at all times during the calendar year. (facteur de capacité)
coal includes petroleum coke and synthetic gas that is derived from coal or petroleum coke. (charbon)
commissioning date means
(a) for an electricity generator that began producing electricity by means of thermal energy using a fuel other than coal, and not in conjunction with coal, but that was converted into a unit before June 23, 2010, the day on which that generator began to produce electricity for sale to the electric grid using fuel other than coal, and not in conjunction with coal; and
(b) in any other case, the day on which a unit begins to produce electricity for sale to the electric grid. (date de mise en service)
existing unit means a unit that is neither an old unit nor a new unit. (groupe existant)
fossil fuel means a fuel other than biomass. (combustible fossile)
front end engineering design study means a collection of studies that provide the necessary details to support the carrying out of a construction project for the capture element of a carbon capture and storage system, including
(a) technical drawings and documents that describe the capture element in sufficient detail to permit the tendering of a contract for its construction;
(b) an estimation of the capital cost of the capture element with a margin of error of ± 20%;
(c) a safety review of the capture element;
(d) a risk assessment of the carbon capture and storage system, namely an assessment of the risks that may delay or prevent the completion of the construction of the system, including technical, economic, environmental, legal and labour-related risks;
(e) a strategy to mitigate those risks; and
(f) a detailed plan to carry out the construction of the carbon capture and storage system, including a schedule for the completion of its major steps. (étude d’ingénierie d’avant-projet détaillé)
gasification system includes a gasification system that is in part located underground. (système de gazéification)
GPA means the Gas Processors Association of the United States. (GPA)
major equipment means a boiler, gasifier, shift reactor, turbine, air pollution control device, air separation unit, compressor, CO2 separation system or other equipment that
(a) is manufactured in accordance with specifications in its purchase order and takes more than 12 months after the date of the purchase order to be manufactured and delivered; or
(b) costs $10,000,000 or more. (équipement majeur)
new unit means a unit, other than an old unit, whose commissioning date is on or after July 1, 2015. (groupe nouveau)
old unit means a unit that has reached the end of its useful life but continues to produce electricity. (groupe en fin de vie utile)
operator means the person that operates or has the charge, management or control of a unit. (exploitant)
power plant means all units, buildings and other structures and all stationary equipment — including equipment for the separation and initial pressurization of CO2 of the capture element of a carbon capture and storage system — on a single site, or on adjacent sites that function as a single integrated site, whose primary purpose is the production of electricity for sale to the electric grid. (centrale électrique)
production capacity, in relation to a unit and a calendar year, means
(a) the maximum continuous rating of the unit, expressed in MW, as most recently reported to a provincial authority of competent jurisdiction or to the electric system operator in the province where the unit is located; or
(b) if no report has been made, the most electricity that was produced for sale by the unit, expressed in MW, during two continuous hours in that calendar year. (capacité de production)
Reference Method means the document entitled Reference Method for Source Testing: Quantification of Carbon Dioxide Releases by Continuous Emission Monitoring Systems from Thermal Power Generation, June 2012, published by the Department of the Environment. (Méthode de référence)
responsible person means an owner or operator of a unit. (personne responsable)
standard m3 has the meaning assigned to a cubic metre at standard pressure and standard temperature by the definition standard volume in subsection 2(1) of the Electricity and Gas Inspection Regulations. (m3 normalisé)
standby unit means an old unit that, for a given calendar year, operates at a capacity factor of 9% or less. (groupe de réserve)
unit means physically connected equipment located in a power plant — including boilers and other combustion devices, gasifiers, reactors, turbines, generators and emission control devices — that operates together to produce electricity by means of thermal energy using coal as a fuel, whether in conjunction with other fuels or not. (groupe)
useful life, in respect of a unit, means the period that begins on the commissioning date and ends on
(a) for a unit other than a unit referred to in paragraph (a) of the definition commissioning date,
(i) in the case of a unit whose commissioning date is before 1975, the earlier of
(A) December 31 of the calendar year that is 50 years after the commissioning date, and
(B) December 31, 2019, and
(ii) in the case of a unit whose commissioning date is after 1974, the earlier of
(A) December 31 of the calendar year that is 50 years after the commissioning date, and
(B) December 31, 2029; and
(b) for a unit referred to in paragraph (a) of the definition commissioning date, 18 months after the applicable date described in paragraph (a). (vie utile)
(2) For the purposes of interpreting documents incorporated by reference into these Regulations, “should” must be read to mean “must” and any recommendation or suggestion must be read as an obligation.
(3) Any standard of the ASTM or GPA that is incorporated by reference into these Regulations is incorporated as amended from time to time.
3 (1) A responsible person for a new unit or an old unit must not, on average, emit with an intensity of more than 420 tonnes CO2 emissions from the combustion of fossil fuels in the unit for each GWh of electricity produced by the unit during a calendar year.
(2) The quantity of
(a) electricity referred to in subsection (1) is to be determined in accordance with section 19; and
(b) emissions referred to in subsection (1) are to be determined in accordance with the applicable provisions of sections 20 to 24.
(3) The CO2 emissions released from the use of sorbent to control the emission of sulphur dioxide from a unit are to be included as CO2 emissions from the combustion of fossil fuels in that unit for the purpose of subsection (1).
(4) Emissions from a gasification system that produces synthetic gas derived from coal or petroleum coke that is used as a fuel to produce electricity from a unit referred to in subsection (1) are to be included as emissions from that unit, for the purpose of subsection (1), if that coal gasification system has at least one responsible person in common with that unit.
(5) The CO2 emissions from a unit referred to in subsection (1) do not include emissions that
(a) are captured in accordance with the laws of Canada or a province that regulate that capture;
(b) are transported and stored in accordance with the laws of Canada or a province, or of the United States or one of its states, that regulate that transportation or storage, as the case may be; and
(c) are not subsequently released into the atmosphere.
(6) For greater certainty, if subsection (1) applies in respect of a unit only for a period during a calendar year, that period is considered to be the calendar year for the purpose of that subsection.
4 (1) A responsible person for a new unit must register the new unit by sending to the Minister, on or before 30 days after its commissioning date, a registration report that contains the information set out in Schedule 1.
(2) On receipt of the registration report, the Minister must assign a registration number to the unit and inform the responsible person of that registration number.
(3) If the information provided in the registration report changes or if the unit is decommissioned, the responsible person must, not later than 30 days after the change or decommissioning, send to the Minister a notice that provides the updated information or that indicates the unit has been decommissioned, as the case may be, along with the date of the decommissioning.
5 (1) For the purpose of subsection 3(1), a responsible person for a unit (referred to in this section as the “original unit”) that reaches the end of its useful life during a calendar year may apply to the Minister to have another unit (referred to in this section as the “substituted unit”) substituted for the original unit if the following conditions are satisfied:
(a) the substituted unit is an existing unit;
(b) the original unit and the substituted unit have a common owner who has an ownership interest of 50% or more in each of those two units;
(c) those two units are located in the same province; and
(d) the production capacity of the substituted unit, during the calendar year preceding the calendar year in which the application is made, was equal to or greater than the production capacity of the original unit during that preceding calendar year.
(2) The application must be made in the period that begins on January 1 and that ends on May 31 of the calendar year during which the unit reaches its end of life.
(3) The application must include the registration number of the original unit and of the substituted unit and information, with supporting documentation, to demonstrate that the conditions of paragraphs (1)(b) to (d) are satisfied.
(4) The Minister must, within 30 days after receiving the application, grant the substitution if the following conditions are satisfied:
(a) the substituted unit is not a shut-down unit referred to in subsection 6(4);
(b) the substituted unit is not involved in an exemption granted under subsection 14(4); and
(c) the Minister is satisfied that the conditions of paragraphs (1)(a) to (d) are satisfied.
(5) On the granting of the substitution, subsection 3(1) applies in respect of the substituted unit rather than the original unit as of the later of
(a) July 1, 2015, and
(b) the beginning of the calendar year that follows the calendar year in which the application is made.
(6) The substitution referred to in subsection (5) ceases to have effect, and subsection 3(1) applies in respect of the original unit, as of the earliest of
(a) the calendar year that follows the day on which the responsible person for that unit and the substituted unit sends the Minister a notice indicating that they wish the substitution to no longer have an effect,
(b) the calendar year that follows the day on which the condition of paragraph (1)(b) is no longer satisfied,
(c) the calendar year that follows a calendar year during which the production capacity of the original unit was more than the production capacity of the substituted unit referred to in paragraph (1)(d),
(d) the calendar year that follows the end of the useful life of the substituted unit, and
(e) a calendar year during which electricity is produced by the substituted unit by means of thermal energy using fossil fuel other than coal, and not in conjunction with coal.
6 (1) A responsible person for an existing unit that ceases to produce electricity after June 30, 2015 (referred to in this section as the “shut-down unit”) may apply to the Minister to have the application of subsection 3(1) deferred in respect of another unit or units (referred to in this section as the “deferred units”) for the number of years in the period that begins on January 1 of the calendar year that follows that cessation and that ends on December 31 of the calendar year in which the useful life of the shut-down unit ends. If the application is granted, the application of subsection 3(1) is, in respect of each calendar year in that period, deferred for the deferred unit and the calendar year that begins after the end of that deferred unit’s useful life that the responsible person specifies in their application.
(2) The application may be made only if the following conditions are satisfied:
(a) the shut-down unit and each of the specified deferred units have a common owner who has an ownership interest of 50% or more in the shut-down unit and in each of those specified deferred units;
(b) the shut-down unit and each of those specified deferred units are located in the same province; and
(c) the production capacity of the shut-down unit, during the calendar year preceding the day on which it ceased production, was greater than or equal to the production capacity of each of those specified deferred units during the calendar year preceding the day on which the application was made.
(3) The application must be made on or before May 31 of the calendar year preceding the earliest of the specified calendar years referred to in subsection (1) and must
(a) indicate the calendar years included in the period referred to in subsection (1);
(b) specify the deferred unit referred to in subsection (1) in respect of each of the calendar years referred to in paragraph (a);
(c) for each of those specified deferred units in respect of each of those calendar years, specify the calendar year that begins after the end of the useful life of the unit for which the application of subsection 3(1) is to be deferred;
(d) indicate the registration number of the shut-down unit and of each of the specified deferred units; and
(e) include information, with supporting documentation, to demonstrate that the conditions of paragraphs (2)(a) to (c) are satisfied.
(4) The Minister must, within 30 days after receiving the application, grant the deferral if the following conditions are satisfied:
(a) the shut-down unit is not a substituted unit referred to in subsection 5(5);
(b) no deferred unit is a unit that is involved in a temporary exemption granted under subsection 9(3); and
(c) the Minister is satisfied that the conditions of paragraphs (2)(a) to (c) are satisfied;
(5) It is prohibited for any person to cause the shut-down unit to recommence producing electricity after the application of subsection 3(1) is deferred in respect of a specified deferred unit.
(6) The responsible person referred to in subsection (1) may change the specified deferred unit in respect of a specified calendar year referred to in paragraph (3)(c) by sending a notice to the Minister if that specified calendar year is not one for which the application of subsection 3(1) has been deferred. The notice must include
(a) the registration number of the proposed new specified deferred unit;
(b) the calendar year that begins after the end of the useful life of the proposed new specified deferred unit for which the application of subsection 3(1) is to be deferred; and
(c) information, with supporting documentation, to demonstrate that the conditions of paragraphs (2)(a) and (b) are satisfied in respect of the proposed new specified deferred unit and the condition of paragraph (2)(c) is satisfied in respect of each specified deferred unit, including the proposed new specified deferred unit, during the calendar year preceding the day on which the notification is sent.
(7) The Minister must, within 30 days after receiving the notification, allow the change if the Minister is satisfied that the demonstration referred to in subsection (6) has been made.
(8) Despite subsection (1), the deferral ceases to have effect and subsection 3(1) applies in respect of the specified deferred units as of the earliest of
(a) the calendar year that follows the calendar year in which the application is made, if a shut-down unit referred to in subsection (1) has not ceased to produce electricity by January 1 of that following calendar year,
(b) any calendar year in which a shut-down unit referred to in subsection (1) recommences to produce electricity,
(c) the calendar year that follows the day on which the Minister receives a notice from the responsible person for the shut-down unit and the deferred units indicating that they wish the deferral to no longer have an effect,
(d) the calendar year that follows the day on which the condition of paragraph (2)(a) is no longer satisfied, and
(e) the calendar year that follows a specified calendar year referred to in paragraph (3)(c) in which the specified deferred unit referred to in that paragraph had a production capacity greater than the production capacity of the shut-down unit during the calendar year preceding the day on which it ceased production.
7 (1) A responsible person for a unit may, under emergency circumstances described in subsection (2), apply to the Minister for an exemption from the application of subsection 3(1) in respect of the unit if the following conditions are satisfied:
(a) as a result of the emergency circumstances, there is a disruption, or a significant risk of disruption, to the electricity supply in the province where the unit is located; and
(b) the operation of the unit will end, decrease the risk of, or mitigate the consequences of, the disruption.
(2) An emergency circumstance is a circumstance
(a) that arises due to an extraordinary, unforeseen and irresistible event; or
(b) under which one or more of the measures referred to in paragraph 1(a) of the Regulations Prescribing Circumstances for Granting Waivers Pursuant to Section 147 of the Act has been made or issued in the province where the unit is located.
(3) The responsible person must, within 15 days after the emergency circumstance arises, provide the Minister with their application. The application must include the unit’s registration number, the date on which the emergency circumstance arose and information, with supporting documentation, to demonstrate that the conditions of paragraphs (1)(a) and (b) are satisfied.
(4) The Minister must, within 30 days after receiving the application, grant the exemption if the Minister is satisfied that the conditions of paragraphs (1)(a) and (b) are satisfied.
(5) The exemption has effect as of the day on which the emergency circumstance arose and ceases to have effect on the earliest of
(a) the day that is 90 days after that day,
(b) the day specified by the Minister, and
(c) the earlier of
(i) the day on which the event referred to in paragraph (2)(a) ceases to cause a disruption, or a significant risk of disruption, to the electricity supply in the province where the unit is located, and
(ii) the day on which the measure, if any, referred to in paragraph (2)(b) ceases to be in effect.
8 (1) If paragraphs 7(1)(a) and (b) will continue to apply on and after the day on which an exemption granted under subsection 7(4) is to cease to have effect, the responsible person may, before that day, apply to the Minister for an extension of the exemption.
(2) The application must include the unit’s registration number and information, with supporting documentation, to demonstrate that
(a) paragraphs 7(1)(a) and (b) will continue to apply after the day on which the exemption is to cease to have effect; and
(b) steps — other than the operation of the unit during the period of the exemption — have been, and are being, taken to end, decrease the risk of, or mitigate the consequences of, the disruption.
(3) The Minister must, within 15 days after receiving the application, grant the extension if the Minister is satisfied that paragraphs (2)(a) and (b) have been demonstrated.
(4) The extension ceases to have effect on the earliest of
(a) the day that is 90 days after the day on which the application for the extension was made,
(b) the day specified by the Minister, and
(c) the day referred to in paragraph 7(5)(c).
9 (1) A responsible person for a new unit or an old unit may apply to the Minister for a temporary exemption from the application of subsection 3(1) in respect of the unit if
(a) in the case of a new unit, the unit is designed to permit its integration with a carbon capture and storage system that is to be constructed; and
(b) in the case of an old unit, the unit may be retrofitted to permit its integration with a carbon capture and storage system that is to be constructed.
(2) The application must indicate the unit’s registration number and include the following supporting documents and information:
(a) a declaration that includes statements indicating that
(i) based on the economic feasibility study referred to in paragraph (b), the unit, when operating with an integrated carbon capture and storage system is, to the best of the responsible person’s knowledge and belief, economically viable, and
(ii) based on the technical feasibility study referred to in paragraph (c) and the implementation plan referred to in paragraph (e), the responsible person expects to satisfy the requirements set out in section 10 and, as a result, to be in compliance with subsection 3(1) by January 1, 2025;
(b) an economic feasibility study that demonstrates the economic viability of the unit when it operates with an integrated carbon capture and storage system and that
(i) provides project cost estimates, with their margin of error, for the construction of the integrated carbon capture and storage system, and
(ii) identifies the source of financing for that construction;
(c) a technical feasibility study that establishes — based on information referred to in Schedule 2 related to the capture, transportation and storage elements of the carbon capture and storage system — that there are no insurmountable technical barriers to carrying out the following activities:
(i) capturing a sufficient volume of CO2 emissions from the combustion of fossil fuels in the unit to enable the responsible person to comply with subsection 3(1),
(ii) transporting the captured CO2 emissions to suitable geological sites for storage, and
(iii) storing the captured CO2 emissions in those suitable geological sites;
(d) a description of any work that has been done to satisfy the requirements set out in section 10, along with the information referred to in Schedule 3 with respect to that work; and
(e) an implementation plan that provides a description of the work to be done, with a schedule for the steps necessary to achieve the following objectives:
(i) satisfaction of the requirements set out in section 10, and
(ii) compliance of the responsible person with subsection 3(1) by January 1, 2025 when the unit is operating with an integrated carbon capture and storage system that captures CO2 emissions from the combustion of fossil fuels in the unit in accordance with the laws of Canada or a province that regulate that capture and that transports and stores those emissions in accordance with the laws of Canada or a province, or of the United States or one of its states, that regulate that transportation or storage, as the case may be.
(3) The Minister must, within 120 days after receiving the application, grant the temporary exemption if
(a) the application includes the documents referred to in subsection (2); and
(b) the information contained in those documents can reasonably be regarded as establishing that
(i) the unit, when operating with an integrated carbon capture and storage system, will be economically viable,
(ii) the capture, transportation and storage elements of the carbon capture and storage system will be technically feasible,
(iii) if applicable, a requirement set out in section 10 has been satisfied by work done before the application was made, and
(iv) the responsible person will satisfy the requirements set out in section 10 and, as a result, will be in compliance with subsection 3(1) by January 1, 2025 when the unit is operating with an integrated carbon capture and storage system.
(4) A temporary exemption, unless revoked under section 13, remains in effect until December 31, 2024.
10 A responsible person who has been granted a temporary exemption in respect of a unit under subsection 9(3) must satisfy the following requirements:
(a) carry out a front end engineering design study by January 1, 2020;
(b) purchase any major equipment that is necessary for the capture element by January 1, 2021;
(c) enter into any contract required for the transportation and storage of CO2 emissions from the unit by January 1, 2022;
(d) take all necessary steps to obtain all permits or approvals required in relation to the construction of the capture element by January 1, 2022; and
(e) ensure that the unit, when operating with an integrated carbon capture and storage system, captures CO2 emissions from the combustion of fossil fuels in the unit in accordance with the laws of Canada or a province that regulate that capture and transports and stores those emissions in accordance with the laws of Canada or a province, or of the United States or one of its states, that regulate that transportation or storage, as the case may be, by January 1, 2024.
11 (1) A responsible person who has been granted a temporary exemption in respect of a unit must, for each calendar year following the granting of the temporary exemption, provide the Minister with an implementation report that indicates the unit’s registration number and includes supporting documents that contain the following information:
(a) the steps taken during that year to construct the capture, transportation and storage elements of the carbon capture and storage system and to integrate those elements with the unit;
(b) any requirement set out in section 10 that was satisfied during that year, along with the information and documents referred to in Schedule 3;
(c) a description of the manner in which those steps were carried out or those requirements were satisfied;
(d) any changes, with respect to the information most recently provided to the Minister, to the proposed engineering design for the capture element, to the preferred transportation methods or routes or to the preferred storage sites, for the carbon capture and storage system; and
(e) a description of any steps necessary, with a schedule for those steps, to achieve the following objectives:
(i) the satisfaction of any requirements set out in section 10 that remain to be satisfied, and
(ii) the compliance of the responsible person with subsection 3(1) by January 1, 2025 when the unit is operating with an integrated carbon capture and storage system that captures CO2 emissions from the combustion of fossil fuels in the unit in accordance with laws of Canada or a province that regulate that capture and transports and stores those emissions in accordance with laws of Canada or a province, or of the United States or one of its states, that regulate, as the case may be, that transportation or storage.
(2) The implementation report must be provided by March 31 of the calendar year that follows the calendar year in question.
12 If any event occurs or any circumstance arises that may prejudice the ability of the responsible person to achieve an objective referred to in paragraph 11(1)(e), the responsible person must send to the Minister, without delay, a notice that indicates the unit’s registration number and contains the following information:
(a) a description of the event or circumstance and the nature of the prejudice;
(b) an explanation of how the prejudice is to be overcome in order to ensure that the objective will be achieved; and
(c) in relation to that explanation, an update to any information previously provided to the Minister under paragraphs 11(1)(c) to (e), together with any necessary supporting documents.
13 (1) The Minister must revoke a temporary exemption granted under subsection 9(3) if
(a) the responsible person does not satisfy a requirement set out in section 10; or
(b) any information indicated or contained in the application for the temporary exemption, in an implementation report referred to in section 11 or in a notice referred to in section 12 is false or misleading.
(2) The Minister may revoke the temporary exemption if
(a) the responsible person has not provided an implementation report in accordance with section 11;
(b) there are reasonable grounds for the Minister to believe that the carbon capture and storage system will not operate so as to capture, transport and store CO2 emissions as described in paragraph 10(e) by the date referred to in that paragraph; or
(c) there are reasonable grounds for the Minister to believe that the responsible person will not emit CO2 from the combustion of fossil fuels in the unit in accordance with subsection 3(1) by January 1, 2025.
(3) The Minister must not revoke the temporary exemption under subsection (1) or (2) unless the Minister has provided the responsible person with
(a) written reasons for the proposed revocation; and
(b) an opportunity to be heard, by written representation, in respect of the proposed revocation.
14 (1) A responsible person for an old unit may, on application made to the Minister, be exempted from the application of subsection 3(1) in respect of the old unit for a period of 24 consecutive months that begins on January 1 of the calendar year that follows the calendar year in which the application is made if the following conditions are satisfied:
(a) an existing unit and the old unit have a common owner who has a ownership interest of 50% or more in each of those two units;
(b) the production capacity of the existing unit, during the calendar year preceding the calendar year in which the application is made, was equal to or greater than the production capacity of the old unit during that preceding calendar year;
(c) the existing unit and the old unit are located in the same province;
(d) the quantity of CO2 emissions from the combustion of fossil fuels in the existing unit is determined in accordance with a system or method referred to in subsection 20(1);
(e) the quantity of CO2 emissions from the combustion of fossil fuels in the existing unit that are captured, transported and stored is determined using a direct measure of the flow of, and the concentration of CO2 in, the emissions from that combustion of fuel;
(f) the emissions referred to in paragraph (e) are captured in accordance with the laws of Canada or a province that regulate that capture and are transported and stored in accordance with the laws of Canada or a province, or of the United States or one of its states, that regulate that transportation or storage, as the case may be;
(g) the emissions referred to in paragraph (e) are captured, transported and stored for a period of seven consecutive calendar years;
(h) the emissions referred to in paragraph (e) comprise at least 30% of the quantity of CO2 emissions produced from the combustion of fossil fuels in the existing unit for each calendar year during that seven-year period; and
(i) the existing unit does not reach the end of its useful life during that seven-year period.
(2) A responsible person for an old unit must apply for the exemption before September 1 of the calendar year preceding the calendar year for which the exemption is sought.
(3) The application must include the registration number of the old unit and of the existing unit and information, with supporting documentation, to demonstrate that
(a) the conditions of paragraphs (1)(a) to (f), (h) and (i) are satisfied; and
(b) at least 30 consecutive months of the period referred to in paragraph (1)(g) have occurred before the day on which the application is made.
(4) The Minister must, within 30 days after receiving the application, grant the exemption if
(a) no exemption referred to in subsection (1) has been previously granted in respect of the old unit;
(b) no exemption referred to in subsection (1) that involved the existing unit has been previously granted;
(c) the existing unit referred to in subsection (1) is not a substituted unit referred to in subsection 5(5); and
(d) the Minister is satisfied that the requirements set out in subsection (3) are satisfied.
(5) A responsible person who has been exempted under subsection (4) in respect of an existing unit must ensure that the conditions of paragraphs (1)(a) to (f), (h) and (i) are satisfied for the portion of the period referred to in paragraph (1)(g) that remains after the occurrence of the period of consecutive months described in paragraph (3)(b).
15 For each calendar year, a responsible person for each of the following units must, on or before June 1 that follows that calendar year, send an annual report to the Minister that contains the information set out in Schedule 4:
(a) a new unit;
(b) an old unit;
(c) a substituted unit referred to in subsection 5(5);
(d) an existing unit referred to in subsection 14(1), if that calendar year is a calendar year included in the remaining portion of the seven consecutive calendar years referred to in subsection 14(5).
16 (1) A report or notice that is required, or an application that is made, under these Regulations must be sent electronically in the form and format specified by the Minister and must bear the electronic signature of an authorized official of the responsible person.
(2) If the Minister has not specified an electronic form and format or if it is impractical to send the report, notice or application electronically in accordance with subsection (1) because of circumstances beyond the person’s control, the report, notice or application must be sent on paper, signed by an authorized official of the responsible person, and in the form and format specified by the Minister. However, if no form and format have been so specified, it may be in any form and format.
17 (1) A responsible person for a unit must make a record
(a) of any notice referred to in subsection 4(3), 5(6) or 6(6) or section 12 that was sent to the Minister and the information that was contained in it, as well as any supporting documents;
(b) of any application referred to in subsection 5(3), 6(3), 7(3), 8(2), 9(2) or 14(3) and the information referred to in the subsection, as well as any supporting documents;
(c) of every direct measure of the flow of, and the concentration of CO2 in, emissions referred to in paragraph 14(1)(e), subsection 20(2) and the descriptions of Enon-ccs in subsection 21(1) and of Eccs in section 22;
(d) of every measurement and calculation used to determine a value of an element of a formula set out in any of sections 19 and 21 to 24;
(e) that demonstrates that any meter referred to in section 19 complies with the requirements of the Electricity and Gas Inspection Act and the Electricity and Gas Inspection Regulations, including a certificate referred to in section 14 of that Act;
(f) for each calendar year during which a responsible person used a continuous emission monitoring system referred to in paragraph 20(1)(a), of any document, record or information referred to in section 8 of the Reference Method;
(g) that demonstrates that the installation, maintenance and calibration of measuring devices referred to in subsection 25(1) was in accordance with that subsection and subsection 25(3) and of every calibration referred to in subsection 25(2); and
(h) of the results of the analysis of every sample collected in accordance with section 27.
(2) Records referred to in paragraphs (1)(c) to (h) must be made as soon as feasible but not later than 30 days after the information to be recorded becomes available.
18 (1) A responsible person who is required under these Regulations to make a record or send a report or notice must keep the record or a copy of the report or notice, as well as any supporting documents that relate to the information contained in that record or copy, for at least seven years after they make the record or send the report or notice. The record or copy must be kept at the person’s principal place of business in Canada or at any other place in Canada where it can be inspected. If the record or copy is kept at any of those other places, the person must provide the Minister with the civic address of that other place.
(2) If the civic address referred to in subsection (1) changes, the responsible person must notify the minister in writing within 30 days after the change.
19 (1) The quantity of electricity referred to in paragraph 3(2)(a) is to be determined in accordance with the following formula:
is the gross quantity of electricity that is produced by the unit during the calendar year, expressed in GWh and measured at the electrical terminals of the generators of the unit using meters that comply with the requirements of the Electricity and Gas Inspection Act and the Electricity and Gas Inspection Regulations; and
is the quantity of electricity that is produced by the unit and used by the power plant in which the unit is located during the calendar year to operate infrastructure and equipment that is attributed to the unit for electricity generation and for separation, but not for pressurization, of CO2, expressed in GWh, determined in accordance with an appropriate method of attribution, based on data collected using meters that comply with the requirements of the Electricity and Gas Inspection Act and the Electricity and Gas Inspection Regulations.
(2) Once a method of attribution is used to make the determination referred to in the description of Gaux for a calendar year, that method of attribution must be used to make that determination for every subsequent calendar year, unless
(a) during a subsequent calendar year, a unit located at the power plant ceases to produce electricity or a new unit is added to those located at the power plant; or
(b) during a subsequent calendar year, the operation of any unit located at the power plant is integrated with a carbon capture and storage system.
(3) If paragraph (2)(a) or (b) applies in a subsequent calendar year, the responsible person must, when making the determination referred to in the description of Gaux in subsection (1) for that subsequent calendar year, use a method of attribution that is appropriate to the circumstances described in that paragraph. Subsection (2) applies in respect of that appropriate method of attribution and that subsequent calendar year as if they were, respectively, the method of attribution and the calendar year referred to in that subsection.
20 (1) For the purposes of sections 3 and 15, the quantity of CO2 emissions from the combustion of fossil fuels in a unit for a calendar year is to be determined
(a) by using a continuous emission monitoring system (CEMS) in accordance with section 21; or
(b) by using a fuel-based method, based on the quantity of carbon in the fossil fuel fed for combustion, in accordance with section 22 and section 23 or 24.
(2) If a coal gasification system referred to in subsection 3(4) is used to produce fuel for a unit, the quantity of emissions from the unit referred to in subsection (1) must be determined in accordance with paragraph (1)(a). To the extent that the emissions from the coal gasification system are not captured, transported and stored as described in subsection 3(5), that quantity must be determined for the purpose of subsection 3(1) by using a direct measure of the flow of, and the concentration of CO2 in, those emissions.
21 (1) If paragraph 20(1)(a) applies, the quantity of CO2 emissions referred to in subsection 20(1) is to be determined in accordance with the following formula:
is the quantity of CO2 emissions, expressed in tonnes, from the unit, “u”, during the calendar year from the combustion of fuel, as measured by the CEMS in accordance with sections 7.1 to 7.7 of the Reference Method;
is the quantity of CO2 emissions, expressed in tonnes, from the combustion of biomass in the unit during the calendar year, determined
by using a fuel-based method
in accordance with paragraph 24(1)(a) or (b), if the unit combusts solid biomass at an average daily rate of less than 3t/day during the given calendar year, and
in accordance with the applicable formula set out in one of paragraphs 23(1)(a) to (c) for the type of biomass combusted, in any other case, or
by using the method, based on data from the CEMS, described in subsection (2); and
is the quantity of CO2 emissions, expressed in tonnes, from the combustion of fuel in the unit, including those emissions referred to in subsection 3(4), during the calendar year — other than the quantity of those emissions as measured by the CEMS and set out in the description of Eu — that is determined using a direct measure of the flow of, and the concentration of CO2 in, the emissions from that combustion of fuel but that is not ultimately captured, transported and stored as described in subsection 3(5).
(2) For the purpose of determining the value of Ebio, the method, based on data from the CEMS, consists of making the following sequence of determinations:
(a) the volume of CO2 emitted from combustion of fuel in the unit for each hour of production of electricity during the calendar year determined in accordance with the following formula:
is the average concentration of CO2 in relation to all gases in the stack emitted from the combustion of fuel in the unit during a given hour, “h”, during which the unit produced electricity in the calendar year — or, if applicable, a calculation made in accordance with section 7.4 of the Reference Method of that average concentration of CO2 based on a measurement of the concentration of oxygen (O2) in those gases in the stack — expressed as a percentage on a wet basis,
is the average volumetric flow during that hour, measured on a wet basis by the stack gas volumetric flow monitor, expressed in standard m3, and
is the period during which the unit produced electricity, expressed in hours;
(b) the volume of CO2 emitted from combustion of fossil fuel in the unit during the calendar year, expressed in standard m3 and referred to in this subsection as Vff, determined in accordance with the following formula:
is the quantity of fossil fuel type “i” combusted in the unit during the calendar year, determined
for a solid fuel, in the same manner as the one used in the determination of Mf in the formula set out in paragraph 23(1)(a) and expressed in tonnes,
for a liquid fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(b) and expressed in kL, and
for a gaseous fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(c) and expressed in standard m3,
is the ith fossil fuel type combusted in the unit during the calendar year, with “i” going from the number 1 to n, where n is the number of fossil fuels so combusted,
is the fuel-specific carbon-based F-factor for each fossil fuel type “i” — being, as the case may be, the default value as set out in column 3 of the table to subsection (3) for that fuel type set out in column 2 or determined for that fuel type in accordance with Appendix A of the Reference Method — expressed in standard m3 of CO2/GJ,
— expressed in GJ/tonne, for a solid fuel, in GJ/kL, for a liquid fuel, and in GJ/standard m3, for a gaseous fuel — is, for each fossil fuel type “i”,
the default higher heating value set out in column 2 of Schedule 5 for that fuel type set out in column 1, and
in the absence of a default higher heating value for that fuel type referred to in paragraph (a), a default higher heating value for that fuel type established by a body that is internationally recognized as being competent to establish default higher heating values for fuels;
(c) the volume of CO2 emitted from the combustion of biomass in the unit during the calendar year, expressed in standard m3 and referred to in this subsection as Vbio, determined in accordance with the following formula:
is the sum of the volumes of CO2 emitted from combustion of fuel in the unit during each hour of production of electricity during the calendar year, as determined under paragraph (a), and
is Vff determined in accordance with the formula set out in paragraph (b); and
(d) the quantity of the CO2 emissions from the combustion of biomass in the unit during the calendar year, namely Ebio determined in accordance with the formula set out in subsection (1), based on the following two determinations:
(i) the fraction of the volume of CO2 emissions from all fuel combusted in the unit attributable to the combustion of biomass in the unit during the calendar year, referred to in this section as Biofr, determined in accordance with the following formula:
is the volume of CO2 emitted from the combustion of biomass in the unit during the calendar year determined in accordance with the formula set out in paragraph (c),
is the value of VT determined in accordance with the formula set out in paragraph (c), and
(ii) the quantity of CO2 emissions described by Ebio determined in accordance with the following formula:
is the fraction of the volume of CO2 emissions from all fuel combusted in the unit attributable to the combustion of biomass in the unit during the calendar year determined in accordance with the formula set out in subparagraph (i),
is the value of Eu determined in the formula set out in subsection (1), and
is the quantity of CO2 emissions, expressed in tonnes, that is released from the use of sorbent to control the emission of sulphur dioxide from the unit during the calendar year, determined in accordance with the following formula:
is the quantity of calcium carbonate (CaCO3) or other sorbent material so used, expressed in tonnes,
is the stoichiometric ratio, on a mole fraction basis, of CO2 released on usage of one mole of sorbent material, where R=1 if the sorbent material is CaCO3, and
is the molecular mass of the sorbent material, where MMs = 100 if the sorbent material is CaCO3.
(3) The default value for the fuel-specific carbon-based F-factor for certain types of fossil fuel is set out in column 3 of the following table:
(4) Despite subsection (1), if there is one or more other units at a power plant where a unit is located and a CEMS measures emissions from that unit and from one or more of those other units at a common stack rather than at the exhaust duct of that unit and of each of those other units that brings those emissions to the common stack, then the quantity of emissions attributable to that unit for the purpose of subsection (1) is determined based on the ratio of the heat input of that unit to the total of the heat input of that unit and of all of those other units sharing the common stack in accordance with the following formula:
is the quantity of fuel type “j” combusted in that unit “u” during the calendar year, determined
for a solid fuel, in the same manner as the one used in the determination of Mf in the formula set out in paragraph 23(1)(a) and expressed in tonnes,
for a liquid fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(b) and expressed in kL, and
for a gaseous fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(c) and expressed in standard m3;
is the higher heating value, determined in accordance with section 24 and expressed in the applicable unit of measure referred to in that section of fuel type “j” combusted during the calendar year in that unit “u”;
is the ith unit located at the power plant with “i” going from the number 1 to n, where n is the number of units that share a common stack;
is the jth fuel type, including types of biomass, combusted during the calendar year in a unit located at the power plant with “j” going from the number 1 to m, where m is the number of those fuel types;
is the quantity of fuel type “j” combusted in each unit “i” during the calendar year, determined for a solid fuel, a liquid fuel and a gaseous fuel, respectively, in the manner set out in the description of Quj;
is the higher heating value, determined in accordance with section 24 and expressed in the applicable unit of measure referred to in that section, of fuel type “j” combusted during the calendar year in unit “i”; and
is the quantity of CO2 emissions, expressed in tonnes, from the combustion of fuels in all the units during the calendar year, measured by a CEMS at the common stack in accordance with subsection 21(1).
22 If paragraph 20(1)(b) applies, the quantity of CO2 emissions referred to in subsection 20(1) is to be determined by the following formula:
is the quantity of CO2 emissions attributable to the combustion of fossil fuel of type “i” in the unit during the calendar year, expressed in tonnes, determined for that fuel type in accordance with section 23 or 24;
is the ith type of fossil fuel combusted in the unit during the calendar year, with “i” going from the number 1 to n, where n is the number of types of fossil fuel so combusted;
is Es determined in accordance with the formula set out in subparagraph 21(2)(d)(ii); and
is the quantity of CO2 in those emissions, expressed in tonnes, from the combustion of fuel in the unit, during the calendar year, that are captured in accordance with the laws of Canada or a province that regulate that capture and that are transported and stored in accordance with the laws of Canada or a province, or of the United States or one of its states, that regulate that transportation or storage, as the case may be, that quantity being determined using a direct measure of the flow of, and the concentration of CO2 in, those emissions.
23 (1) Subject to section 24, the quantity of CO2 emissions attributable to the combustion of a fuel in a unit during a calendar year, expressed in tonnes, is determined in accordance with the applicable formula, as follows:
(a) for a solid fuel
is the mass of the fuel combusted during the calendar year as determined, as the case may be, on a wet or dry basis, expressed in tonnes and measured by a measuring device, and
is the weighted average, expressed in kg of carbon per kg of the fuel, of the carbon content of the fuel determined in accordance with subsection (2) on the same wet or dry basis as the one used in the determination of Mf;
(b) for a liquid fuel
is the volume of the fuel combusted during the calendar year, expressed in kL, determined by using flow meters, and
is the weighted average, expressed in tonnes of carbon per kL of the fuel, of the carbon content of the fuel determined in accordance with subsection (2) at the same temperature as the one used in the determination of Vf; and
(c) for a gaseous fuel
is the volume of the fuel combusted during the calendar year, expressed in standard m3, determined by using flow meters,
is the weighted average, expressed in kg of carbon per kg of the fuel, of the carbon content of the fuel determined in accordance with subsection (2),
is the average molecular mass of the fuel, expressed in kg per kg-mole of the fuel, determined based on fuel samples collected in accordance with section 27, and
is the molar volume conversion factor, namely 23.645 standard m3 per kg-mole of the fuel at standard conditions of 15°C and 101.325 kPa.
(2) The weighted average referred to in paragraphs (1)(a) to (c) as CCA is, based on fuel samples collected in accordance with section 27, to be determined in accordance with the following formula:
is the carbon content of, as the case may be, the composite sample, or the sample, of the fuel for the ith sampling period expressed for solid fuels, liquid fuels and gaseous fuels, respectively, in the same unit of measure as the one set out in CCA, as provided by the supplier of the fuel to the responsible person and, if not so provided, as determined by the responsible person, and measured
for a solid fuel, on the same wet or dry basis as the one used in the determination of CCA, in accordance with,
for coal, biomass or solid fuel derived from waste, ASTM D5373 - 08, entitled Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen in Laboratory Samples of Coal, and
for any other solid fuel,
an applicable ASTM standard for the measurement of the carbon content of the fuel, and
if no such ASTM standard applies, an applicable internationally recognized method for the measurement of the carbon content of the fuel,
for a liquid fuel, in accordance with any of the following standards or methods that applies for the measurement of the carbon content of the fuel:
ASTM D3238 - 95(2010), entitled Standard Test Method for Calculation of Carbon Distribution and Structural Group Analysis of Petroleum Oils by the n-d-M Method, along with either of the following applicable ASTM standards:
ASTM D2503 - 92(2007), entitled Standard Test Method for Relative Molecular Mass (Molecular Weight) of Hydrocarbons by Thermoelectric Measurement of Vapor Pressure, and
ASTM D2502 - 04(2009), entitled Standard Test Method for Estimation of Molecular Weight (Relative Molecular Mass) of Petroleum Oils From Viscosity Measurements,
ASTM D5291 - 10, entitled Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen in Petroleum Products and Lubricants, and
if no such ASTM standard applies, an applicable internationally recognized method, and
for a gaseous fuel,
in accordance with either of the following ASTM standards that applies for the measurement of the carbon content of the fuel:
ASTM D1945 - 03(2010), entitled Standard Test Method for Analysis of Natural Gas by Gas Chromatography, and
ASTM D1946 - 90(2011), entitled Standard Practice for Analysis of Reformed Gas by Gas Chromatography, or
by means of a direct measuring device that determines the carbon content of the fuel;
is the ith sampling period referred to in section 27, with “i” going from the number 1 to n, where n is the number of those sampling periods; and
is the mass or volume, as the case may be, of the fuel combusted during the ith sampling period, expressed
for a solid fuel, in tonnes, on the same wet or dry basis as the one used in the determination of CCA,
for a liquid fuel, in kL, and
for a gaseous fuel, in standard m3.
24 (1) For an eligible fuel referred to in subsection (2), the quantity of CO2 emissions attributable to the combustion of the fuel in a unit during a calendar year, expressed in tonnes, may be determined in accordance with subsection (4) based on the following higher heating value of the fuel:
(a) the higher heating value of the fuel that is measured in accordance with subsection (6) as provided by the supplier of the fuel to the responsible person but, if not so provided, as so measured by the responsible person; and
(b) in the absence of a measured higher heating value of the fuel referred to in paragraph (a), the default higher heating value, set out in column 2 of Schedule 5, for the fuel’s type, as set out in column 1 but, in the absence of that default higher heating value, a default higher heating value for that fuel type established by a body that is internationally recognized as being competent to establish default higher heating values for fuels.
(2) Eligible fuels are
(a) a fuel combusted in a unit in respect of which an exemption from the application of subsection 3(1) has been granted under subsection 7(4);
(b) a fuel referred to in section 23 that is combusted during the calendar year at less than any of the average daily rates referred to in subsection (3);
(c) a fuel listed in Table 4 to Schedule 5; and
(d) a fuel combusted in a standby unit.
(3) The average daily rates are
(a) for a solid fuel, 3 t/day;
(b) for a liquid fuel, 1900 L/day; and
(c) for a gaseous fuel, 500 standard m3/day.
(4) The quantity of emissions is to be determined in accordance with the following formula:
is the quantity of the fuel combusted in the unit during the calendar year determined
for a solid fuel, in the same manner as the one used in the determination of Mf in the formula set out in paragraph 23(1)(a) and expressed in tonnes,
for a liquid fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(b) and expressed in kL, and
for a gaseous fuel, in the same manner as the one used in the determination of Vf in the formula set out in paragraph 23(1)(c) and expressed in standard m3;
— expressed in GJ/tonne, for a solid fuel, in GJ/kL, for a liquid fuel, and in GJ/standard m3, for a gaseous fuel — is
if paragraph (1)(a) applies, the weighted average higher heating value of the fuel, determined in accordance with subsection (5), based on fuel samples collected in accordance with section 27, and
if paragraph (1)(b) applies, the default higher heating value, set out in column 2 of Schedule 5, for the fuel’s type, as set out in column 1 and, in the absence of that default higher heating value, a default higher heating value for that fuel type established by a body that is internationally recognized as being competent to establish default higher heating values for fuels; and
is the default CO2 emission factor, set out in column 3 of Schedule 5, for that fuel listed in column 1 and, in the absence of that default CO2 emission factor, a default CO2 emission factor for that fuel established by a body that is internationally recognized as competent to establish default CO2 emission factors for fuels.
(5) The weighted average higher heating value of the fuel is determined in accordance with the following formula:
is the higher heating value of, as the case may be, each composite sample, or sample, of the fuel for t