Beta
7 CFR § 42.140
7 CFR § 42.140 — § 42.140 Operating Characteristic (OC) curves for on-line sampling and inspection.
Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.
Analyze this law with AI§ 42.140 Operating Characteristic (OC) curves for on-line sampling and inspection.
(a) This section contains the Operating Characteristic (OC) curve for each of the sampling plans given in Tables I, I-A, II, II-A, III, and III-A. The OC curve and the corresponding sampling plans are listed by AQL.
(b) Different acceptance and rejection criteria are provided for each AQL. The criteria for each AQL must be obtained from the applicable sampling plan tables.
(c) The curves show the ability of the various sampling plans to distinguish between good and bad lots. This can be illustrated by examining OC curve 6 for an AQL of 0.25 defects per hundred units in the Reduced and Normal Inspection Plans. If the quality of the lots submitted for inspection is poorer than the AQL of 0.25 defects per hundred units, fewer lots will be accepted. For example, OC curve 6 shows that when the quality of lots submitted for inspection is 1.0 defects per hundred units, only 26 percent of the lots are expected to be accepted. Conversely when the quality of the lots submitted for inspection is better than the AQL of 0.25 defects per hundred units, most lots are expected to be accepted. For example, the same OC curve 6 shows that when the quality of lots submitted for inspection is 0.10 defects per hundred units, about 99 percent of the lots are expected to be accepted.
(d) The table of sampling plans that correspond to OC curve 6 can be found over the curves for an AQL of 0.25 defects per hundred units in the Reduced and Normal Inspection Plan. An examination of this table reveals that there is one single and one double sampling plan that have OC curves comparable to OC curve 6. The first plan listed is a single plan requiring the inspection of 500 individual containers. Under this plan the lot is accepted as meeting the requirements for an AQL of 0.25 if there are 3 or less defects in the sample or rejected if there are 4 or more defects in the sample.
(e) The next plan that is listed in the column headed 6 for an AQL of 0.25 is a double sampling plan that requires the initial inspection of 228 individual containers. The lot will be accepted as meeting the requirements of an AQL of 0.25 if there are no defects in the sample, and rejected if there are 3 or more defects in the sample. In the event that the number of defects is between the acceptance (0) and rejection (3) numbers, additional containers must be inspected. In this case, the table indicates that a total of 516 containers must be inspected before a decision can be made to either accept or reject the lot. This will require the inspection of 288 more containers (516 − 228 = 288).
If there are 3 or less defects in the total sample, the lot will be accepted. If there are 4 or more defects in the total sample, the lot will be rejected. The other double sampling plans operate in a similar manner with the only differences being the sample sizes and acceptance and rejection numbers.
Reduced and Normal Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 0.15 Defects per Hundred Units [Sampling plans—AQL = 0.15]
Comparable sampling plans
Identification number of OC curve
R1
R2
R3
R4
N4
N5
N6
N7
N8
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
29
1
2
84
1
2
126
0
1
315
1
2
168
1
2
264
1
2
500
2
3
800
3
4
1,250
4
5
Double
18
0
2
36
0
2
120
0
2
174
0
2
252
0
3
456
0
4
36
1
2
96
1
2
180
1
2
336
1
2
540
2
3
864
3
4
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Tightened Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 0.15 Defects per Hundred Units [Sampling plans—AQL = 0.15]
Comparable sampling plans
Identification number of OC curves
1
2
3
4
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
264
0
1
500
1
2
800
2
3
1,250
3
4
Double
360
0
2
456
0
3
576
0
3
516
1
2
864
2
3
1,296
3
4
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Reduced and Normal Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 0.25 Defects per Hundred Units [Sampling plans—AQL = 0.25]
Comparable sampling plans
Identification number OC curves
R1
N2
R3
N and R4
N and R5
N6
N7
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
29
1
2
84
0
1
84
1
2
168
1
2
315
2
3
500
3
4
800
4
5
Double
18
0
2
36
0
2
120
0
2
168
0
3
228
0
3
18
1
2
96
1
2
180
1
2
348
2
3
516
3
4
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Tightened Inspection Plans—Sampling Plans and Operation Characteristics (OC) Curves for AQL = 0.25 Defects per Hundred Units [Sampling plans—AQL = 0.25]
Comparable sampling plans
Identification number of OC curves
1
2
3
4
5
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
168
0
1
315
1
2
500
2
3
800
3
4
1,250
4
5
Double
168
0
2
228
0
3
456
0
4
348
1
2
516
2
3
864
3
4
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Reduced and Normal Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 0.50 Defects per Hundred Units [Sampling plans—AQL = 0.50]
Comparable sampling plans
Identification number of OC curves
R1
N and R2
N and R3
N and R4
N5
N6
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
29
1
2
84
1
2
168
2
3
315
3
4
500
5
6
800
7
8
Double
18
0
2
36
0
2
120
0
3
168
0
4
228
0
5
36
1
2
96
1
2
180
2
3
348
3
4
516
5
6
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Tightened Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 0.50 Defects per Hundred Units [Sampling plans—AQL = 0.50]
Comparable sampling plans
Identification number of OC curves
1
2
3
4
5
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
168
1
2
315
2
3
500
3
4
800
4
5
1,250
6
7
Double
120
0
2
168
0
3
228
0
3
456
1
5
180
1
2
348
2
3
516
3
4
864
4
5
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Reduced and Normal Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 1.00 Defects per Hundred Units [Sampling plans—AQL = 1.00]
Comparable sampling plans
Identification number of OC curves
R1
N and R2
N and R3
N and R4
N5
N6
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
29
1
2
84
2
3
168
4
5
315
6
7
500
9
10
800
13
14
Double
18
0
2
36
0
3
120
2
5
168
1
5
228
2
7
36
1
2
96
2
3
180
4
5
348
7
8
516
9
10
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Tightened Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 1.00 Defects per Hundred Units [Sampling plans—AQL = 1.00]
Comparable sampling plans
Identification number of OC curves
1
2
3
4
5
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
168
2
3
315
3
4
500
5
6
800
7
8
1,250
10
11
Double
120
0
3
168
0
4
228
0
5
456
2
6
180
2
3
348
3
4
516
5
6
864
8
9
n c = Cumulative sample size Ac = Acceptance number. Re = Rejection number.
Reduced and Normal Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 1.50 Defects per Hundred Units [Sampling plans—AQL = 1.50]
Comparable sampling plans
Identification number of OC curves
R1
N and R2
N and R3
N and R4
N5
N6
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
29
1
2
84
3
4
168
5
6
315
8
9
500
12
13
800
18
19
Double
18
0
2
36
0
4
120
2
6
168
2
7
228
3
9
36
1
2
96
3
4
180
5
6
348
9
10
516
12
13
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Tightened Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 1.50 Defects per Hundred Units [Sampling plans—AQL = 1.50]
Comparable sampling plans
Identification number of OC curves
1
2
3
4
5
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
168
4
5
315
6
7
500
9
10
800
13
14
1,250
19
20
Double
120
2
5
168
1
5
228
2
7
456
5
10
180
4
5
348
7
8
516
9
10
864
14
15
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Reduced and Normal Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 2.50 Defects per Hundred Units [Sampling plans—AQL = 2.50]
Comparable sampling plans
Identification number of OC curves
R1
N and R2
N and R3
N and R4
N5
N6
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
29
2
3
84
4
5
168
7
8
315
13
14
500
18
19
800
27
28
Double
18
0
3
36
0
4
120
3
7
168
5
10
228
5
11
36
2
3
96
4
5
180
8
9
348
14
15
516
19
20
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Tightened Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 2.50 Defects per Hundred Units [Sampling plans—AQL = 2.50]
Comparable sampling plans
Identification number of OC curves
1
2
3
4
5
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
168
5
6
315
8
9
500
12
13
800
18
19
1,250
26
27
Double
120
2
6
168
2
7
228
3
9
456
8
13
180
5
6
348
9
10
516
12
13
864
19
20
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Reduced and Normal Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 4.00 Defects per Hundred Units [Sampling plans—AQL = 4.00]
Comparable sampling plans
Identification number of OC curves
R1
N and R2
N and R3
N and R4
N5
N6
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
29
3
4
84
6
7
168
11
12
315
19
20
500
28
29
800
42
43
Double
18
1
3
36
0
5
120
6
10
168
7
13
228
8
17
36
4
5
96
7
8
180
12
13
348
21
22
516
29
30
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Tightened Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 4.00 Defects per Hundred Units [Sampling plans—AQL = 4.00]
Comparable sampling plans
Identification number of OC curves
1
2
3
4
5
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
168
7
8
315
13
14
500
18
19
800
27
28
1,250
41
42
Double
120
3
7
168
5
10
228
5
11
456
12
19
180
8
9
348
14
15
516
19
20
864
29
30
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Reduced and Normal Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 2.50 Defects per Hundred Units [Sampling plans—AQL = 6.50]
Comparable sampling plans
Identification number of OC curves
R1
N and R2
N and R3
N and R4
N5
N6
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
29
4
5
84
9
10
168
16
17
315
28
29
500
42
43
800
64
65
Double
18
1
4
36
2
7
120
10
14
168
12
18
228
15
24
36
5
6
96
10
11
180
17
18
348
31
32
516
43
44
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Tightened Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 6.50 Defects per Hundred Units [Sampling plans—AQL = 6.50]
Comparable sampling plans
Identification number of OC curves
1
2
3
4
5
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
168
11
12
315
19
20
500
28
29
800
42
43
1,250
63
64
Double
120
6
10
168
7
13
228
8
17
456
21
28
180
12
13
348
21
22
516
29
30
864
44
45
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Reduced and Normal Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 10.00 Defects per Hundred Units [Sampling plans—AQL = 10.00]
Comparable sampling plans
Identification number of OC curves
R1
N and R2
N and R3
N and R4
N5
N6
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
29
5
6
84
13
14
168
23
24
315
41
42
500
62
63
800
95
96
Double
18
2
5
36
3
9
120
14
19
168
19
26
228
23
34
36
6
7
96
15
16
180
25
26
348
45
46
516
64
65
n c = Cumulative sample size. Ac = Acceptance number. Re = Rejection number.
Tightened Inspection Plans—Sampling Plans and Operating Characteristic (OC) Curves for AQL = 10.00 Defects per Hundred Units [Sampling plans—AQL = 10.00]
Comparable sampling plans
Identification number of OC curves
1
2
3
4
5
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
n c
Ac
Re
Single
168
16
17
315
28
29
500
42
43
800
64
65
1,250
96
97
Double
120
10
14
168
12
18
228
15
24
456
32
41
180
17
18
348
31
32
516
43
44
864
69
70
n c = Cumulative sampling size. Ac = Acceptance number. Re = Rejection number.
[31 FR 4687, Mar. 19, 1966; 31 FR 4949, Mar. 25, 1966, as amended at 36 FR 18457, Sept. 15, 1971. Redesignated at 41 FR 42640, Sept. 28, 1976 and 42 FR 32514, June 27, 1977, further redesignated at 45 FR 69424, Oct. 21, 1980 and 46 FR 63203, Dec. 31, 1981]