LEGALDIGMLEGALDIGM
    ← Code of Federal Regulations
    Beta
    10 CFR § 430.32

    10 CFR § 430.32 — § 430.32 Energy and water conservation standards and their compliance dates.

    Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.

    Analyze this law with AI
    § 430.32 Energy and water conservation standards and their compliance dates. Link to an amendment published at 89 FR 105285, Dec. 26, 2024. This amendment is delayed until Mar. 21, 2025 at 90 FR 9951, Feb. 20, 2025. Amendment is further delayed until May 20, 2025 at 90 FR 13054, Mar. 20, 2025. The energy and water (in the case of faucets, showerheads, water closets, and urinals) conservation standards for the covered product classes are: (a) Refrigerators/refrigerator-freezers/freezers. These standards do not apply to refrigerators and refrigerator-freezers with total refrigerated volume exceeding 39 cubic feet (1104 liters) or freezers with total refrigerated volume exceeding 30 cubic feet (850 liters). The energy standards as determined by the equations of the following table(s) shall be rounded off to the nearest kWh per year. If the equation calculation is halfway between the nearest two kWh per year values, the standard shall be rounded up to the higher of these values. (1) The following standards apply to products manufactured on or after September 15, 2014, and before the 2029/2030 compliance dates depending on product class (see paragraphs (a)(2) and (a)(3) of this section). Table 1 to Paragraph (a)(1) Product class Equations for maximum energy use (kWh/yr) based on AV (ft 3 ) based on av (L) 1. Refrigerators and refrigerator-freezers with manual defrost 7.99AV + 225.0 0.282av + 225.0 1A. All-refrigerators—manual defrost 6.79AV + 193.6 0.240av + 193.6 2. Refrigerator-freezers—partial automatic defrost 7.99AV + 225.0 0.282av + 225.0 3. Refrigerator-freezers—automatic defrost with top-mounted freezer without an automatic icemaker 8.07AV + 233.7 0.285av + 233.7 3-BI. Built-in refrigerator-freezer—automatic defrost with top-mounted freezer without an automatic icemaker 9.15AV + 264.9 0.323av + 264.9 3I. Refrigerator-freezers—automatic defrost with top-mounted freezer with an automatic icemaker without through-the-door ice service 8.07AV + 317.7 0.285av + 317.7 3I-BI. Built-in refrigerator-freezers—automatic defrost with top-mounted freezer with an automatic icemaker without through-the-door ice service 9.15AV + 348.9 0.323av + 348.9 3A. All-refrigerators—automatic defrost 7.07AV + 201.6 0.250av + 201.6 3A-BI. Built-in All-refrigerators—automatic defrost 8.02AV + 228.5 0.283av + 228.5 4. Refrigerator-freezers—automatic defrost with side-mounted freezer without an automatic icemaker 8.51AV + 297.8 0.301av + 297.8 4-BI. Built-In Refrigerator-freezers—automatic defrost with side-mounted freezer without an automatic icemaker 10.22AV + 357.4 0.361av + 357.4 4I. Refrigerator-freezers—automatic defrost with side-mounted freezer with an automatic icemaker without through-the-door ice service 8.51AV + 381.8 0.301av + 381.8 4I-BI. Built-In Refrigerator-freezers—automatic defrost with side-mounted freezer with an automatic icemaker without through-the-door ice service 10.22AV + 441.4 0.361av + 441.4 5. Refrigerator-freezers—automatic defrost with bottom-mounted freezer without an automatic icemaker 8.85AV + 317.0 0.312av + 317.0 5-BI. Built-In Refrigerator-freezers—automatic defrost with bottom-mounted freezer without an automatic icemaker 9.40AV + 336.9 0.332av + 336.9 5I. Refrigerator-freezers—automatic defrost with bottom-mounted freezer with an automatic icemaker without through-the-door ice service 8.85AV + 401.0 0.312av + 401.0 5I-BI. Built-In Refrigerator-freezers—automatic defrost with bottom-mounted freezer with an automatic icemaker without through-the-door ice service 9.40AV + 420.9 0.332av + 420.9 5A. Refrigerator-freezer—automatic defrost with bottom-mounted freezer with through-the-door ice service 9.25AV + 475.4 0.327av + 475.4 5A-BI. Built-in refrigerator-freezer—automatic defrost with bottom-mounted freezer with through-the-door ice service 9.83AV + 499.9 0.347av + 499.9 6. Refrigerator-freezers—automatic defrost with top-mounted freezer with through-the-door ice service 8.40AV + 385.4 0.297av + 385.4 7. Refrigerator-freezers—automatic defrost with side-mounted freezer with through-the-door ice service 8.54AV + 432.8 0.302av + 431.1 7-BI. Built-In Refrigerator-freezers—automatic defrost with side-mounted freezer with through-the-door ice service 10.25AV + 502.6 0.362av + 502.6 8. Upright freezers with manual defrost 5.57AV + 193.7 0.197av + 193.7 9. Upright freezers with automatic defrost without an automatic icemaker 8.62AV + 228.3 0.305av + 228.3 9I. Upright freezers with automatic defrost with an automatic icemaker 8.62AV + 312.3 0.305av + 312.3 9-BI. Built-In Upright freezers with automatic defrost without an automatic icemaker 9.86AV + 260.9 0.348av + 260.6 9I-BI. Built-In Upright freezers with automatic defrost with an automatic icemaker 9.86AV + 344.9 0.348av + 344.9 10. Chest freezers and all other freezers except compact freezers 7.29AV + 107.8 0.257av + 107.8 10A. Chest freezers with automatic defrost 10.24AV + 148.1 0.362av + 148.1 11. Compact refrigerators and refrigerator-freezers with manual defrost 9.03AV + 252.3 0.319av + 252.3 11A. Compact refrigerators and refrigerator-freezers with manual defrost 7.84AV + 219.1 0.277av + 219.1 12. Compact refrigerator-freezers—partial automatic defrost 5.91AV + 335.8 0.209av + 335.8 13. Compact refrigerator-freezers—automatic defrost with top-mounted freezer 11.80AV + 339.2 0.417av + 339.2 13I. Compact refrigerator-freezers—automatic defrost with top-mounted freezer with an automatic icemaker 11.80AV + 423.2 0.417av + 423.2 13A. Compact all-refrigerator—automatic defrost 9.17AV + 259.3 0.324av + 259.3 14. Compact refrigerator-freezers—automatic defrost with side-mounted freezer 6.82AV + 456.9 0.241av + 456.9 14I. Compact refrigerator-freezers—automatic defrost with side-mounted freezer with an automatic icemaker 6.82AV + 540.9 0.241av + 540.9 15. Compact refrigerator-freezers—automatic defrost with bottom-mounted freezer 11.80AV + 339.2 0.417av + 339.2 15I. Compact refrigerator-freezers—automatic defrost with bottom-mounted freezer with an automatic icemaker 11.80AV + 423.2 0.417av + 423.2 16. Compact upright freezers with manual defrost 8.65AV + 225.7 0.306av + 225.7 17. Compact upright freezers with automatic defrost 10.17AV + 351.9 0.359av + 351.9 18. Compact chest freezers 9.25AV + 136.8 0.327av + 136.8 AV = Total adjusted volume, expressed in ft 3 , as determined in appendices A and B to subpart B of this part. av = Total adjusted volume, expressed in Liters. (2) The following standards apply to products manufactured on or after January 31, 2029. Table 2 to Paragraph ( a )( 2 ) Product class Equations for maximum energy use (kWh/yr) Based on AV (ft 3 ) Based on av (L) 3-BI. Built-in refrigerator-freezer—automatic defrost with top-mounted freezer 8.24AV + 238.4 + 28I 0.291av + 238.4 + 28I. 3A-BI. Built-in All-refrigerators—automatic defrost (7.22AV + 205.7) * K3ABI (0.255av + 205.7) * K3ABI. 4-BI. Built-In Refrigerator-freezers—automatic defrost with side-mounted freezer (8.79AV + 307.4) * K4BI + 28I (0.310av + 307.4) * K4BI + 28I. 5-BI. Built-In Refrigerator-freezers—automatic defrost with bottom-mounted freezer (8.65AV + 309.9) * K5BI + 28I (0.305av + 309.9) * K5BI + 28I. 5A. Refrigerator-freezer—automatic defrost with bottom-mounted freezer with through-the-door ice service (7.76AV + 351.9) * K5A (0.274av + 351.9) * K5A. 5A-BI. Built-in refrigerator-freezer—automatic defrost with bottom-mounted freezer with through-the-door ice service (8.21AV + 370.7) * K5ABI (0.290av + 370.7) * K5ABI. 7-BI. Built-In Refrigerator-freezers—automatic defrost with side-mounted freezer with through-the-door ice service (8.82AV + 384.1) * K7BI (0.311av + 384.1) * K7BI. 8. Upright freezers with manual defrost 5.57AV + 193.7 0.197av + 193.7. 9-BI. Built-In Upright freezers with automatic defrost (9.37AV + 247.9) * K9BI + 28I (0.331av + 247.9) * K9BI + 28I. 9A-BI. Built-In Upright freezers with automatic defrost with through-the-door ice service 9.86AV + 288.9 0.348av + 288.9. 10. Chest freezers and all other freezers except compact freezers 7.29AV + 107.8 0.257av + 107.8. 10A. Chest freezers with automatic defrost 10.24AV + 148.1 0.362av + 148.1. 11. Compact refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost 7.68AV + 214.5 0.271av + 214.5. 11A. Compact all-refrigerators—manual defrost 6.66AV + 186.2 0.235av + 186.2. 12. Compact refrigerator-freezers—partial automatic defrost (5.32AV + 302.2) * K12 (0.188av + 302.2) * K12. 13. Compact refrigerator-freezers—automatic defrost with top-mounted freezer 10.62AV + 305.3 + 28I 0.375av + 305.3 + 28I. 13A. Compact all-refrigerators—automatic defrost (8.25AV + 233.4) * K13A (0.291av + 233.4) * K13A. 14. Compact refrigerator-freezers—automatic defrost with side-mounted freezer 6.14AV + 411.2 + 28I 0.217av + 411.2 + 28I. 15. Compact refrigerator-freezers—automatic defrost with bottom-mounted freezer 10.62AV + 305.3 + 28I 0.375av + 305.3 + 28I. 16. Compact upright freezers with manual defrost 7.35AV + 191.8 0.260av + 191.8. 17. Compact upright freezers with automatic defrost 9.15AV + 316.7 0.323av + 316.7. 18. Compact chest freezers 7.86AV + 107.8 0.278av + 107.8. AV = Total adjusted volume, expressed in ft 3 , as determined in appendices A and B to subpart B of this part. av = Total adjusted volume, expressed in Liters. I = 1 for a product with an automatic icemaker and = 0 for a product without an automatic icemaker. Door Coefficients ( e.g., K3ABI) are as defined in the following table. Table 3 to Paragraph ( a )( 2 ) Door coefficient Products with a transparent door Products without a transparent door with a door-in-door Products without a transparent door or door-in-door with added external doors K3ABI 1.10 1.0 1.0. K4BI 1.10 1.06 1 + 0.02 * (N d −2). K5BI 1.10 1.06 1 + 0.02 * (N d −2). K5A 1.10 1.06 1 + 0.02 * (N d −3). K5ABI 1.10 1.06 1 + 0.02 * (N d −3). K7BI 1.10 1.06 1 + 0.02 * (N d −2). K9BI 1.0 1.0 1 + 0.02 * (N d −1). K12 1.0 1.0 1 + 0.02 * (N d −1). K13A 1.10 1.0 1.0. Notes: 1 N d is the number of external doors. 2 The maximum N d values are 2 for K12, 3 for K9BI, and 5 for all other K values. (3) The following standards apply to products manufactured on or after January 31, 2030. Table 4 to Paragraph ( a )( 3 ) Product class Equations for maximum energy use (kWh/yr) Based on AV (ft 3 ) Based on av (L) 1. Refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost 6.79AV + 191.3 0.240av + 191.3. 1A. All-refrigerators—manual defrost 5.77AV + 164.6 0.204av + 164.6. 2. Refrigerator-freezers—partial automatic defrost (6.79AV + 191.3) * K2 (0.240av + 191.3) * K2. 3. Refrigerator-freezers—automatic defrost with top-mounted freezer 6.86AV + 198.6 + 28I 0.242av + 198.6 + 28I. 3A. All-refrigerators—automatic defrost (6.01AV + 171.4) * K3A (0.212av + 171.4) * K3A. 4. Refrigerator-freezers—automatic defrost with side-mounted freezer (7.28AV + 254.9) * K4 + 28I (0.257av + 254.9) * K4 + 28I. 5. Refrigerator-freezers—automatic defrost with bottom-mounted freezer (7.61AV + 272.6) * K5 + 28I (0.269av + 272.6) * K5 + 28I. 6. Refrigerator-freezers—automatic defrost with top-mounted freezer with through-the-door ice service 7.14AV + 280.0 0.252av + 280.0. 7. Refrigerator-freezers—automatic defrost with side-mounted freezer with through-the-door ice service (7.31AV + 322.5) * K7 (0.258av + 322.5) * K7. 9. Upright freezers with automatic defrost (7.33AV + 194.1) * K9 + 28I (0.259av + 194.1) * K9 + 28I. AV = Total adjusted volume, expressed in ft 3 , as determined in appendices A and B to subpart B of this part. av = Total adjusted volume, expressed in Liters. I = 1 for a product with an automatic icemaker and = 0 for a product without an automatic icemaker. Door Coefficients ( e.g., K3A) are as defined in the following table. Table 5 to Paragraph ( a )( 3 ) Door coefficient Products with a transparent door Products without a transparent door with a door-in-door Products without a transparent door or door-in-door with added external doors K2 1.0 1.0 1 + 0.02 * (N d −1). K3A 1.10 1.0 1.0. K4 1.10 1.06 1 + 0.02 * (N d −2). K5 1.10 1.06 1 + 0.02 * (N d −2). K7 1.10 1.06 1 + 0.02 * (N d −2). K9 1.0 1.0 1 + 0.02 * (N d −1). Notes: 1 N d is the number of external doors. 2 The maximum N d values are 2 for K2, and 5 for all other K values. (b) Room air conditioners. (1) The following standards remain in effect from June 1, 2014, until May 26, 2026: Table 6 to Paragraph ( b )(1) Equipment class Combined energy efficiency ratio 1. Without reverse cycle, with louvered sides, and with a certified cooling capacity 1 less than 6,000 Btu/h 11.0 2. Without reverse cycle, with louvered sides and with a certified cooling capacity of 6,000 to 7,999 Btu/h 11.0 3. Without reverse cycle, with louvered sides and with a certified cooling capacity of 8,000 to 13,999 Btu/h 10.9 4. Without reverse cycle, with louvered sides and with a certified cooling capacity of 14,000 to 19,999 Btu/h 10.7 5a. Without reverse cycle, with louvered sides and with a certified cooling capacity of 20,000 Btu/h to 27,999 Btu/h 9.4 5b. Without reverse cycle, with louvered sides and with a certified cooling capacity of 28,000 Btu/h or more 9.0 6. Without reverse cycle, without louvered sides, and with a certified cooling capacity less than 6,000 Btu/h 10.0 7. Without reverse cycle, without louvered sides and with a certified cooling capacity of 6,000 to 7,999 Btu/h 10.0 8a. Without reverse cycle, without louvered sides and with a certified cooling capacity of 8,000 to 10,999 Btu/h 9.6 8b. Without reverse cycle, without louvered sides and with a certified cooling capacity of 11,000 to 13,999 Btu/h 9.5 9. Without reverse cycle, without louvered sides and with a certified cooling capacity of 14,000 to 19,999 Btu/h 9.3 10. Without reverse cycle, without louvered sides and with a certified cooling capacity of 20,000 Btu/h or more 9.4 11. With reverse cycle, with louvered sides, and with a certified cooling capacity less than 20,000 Btu/h 9.8 12. With reverse cycle, without louvered sides, and with a certified cooling capacity less than 14,000 Btu/h 9.3 13. With reverse cycle, with louvered sides, and with a certified cooling capacity of 20,000 Btu/h or more 9.3 14. With reverse cycle, without louvered sides, and with a certified cooling capacity of 14,000 Btu/h or more 8.7 15. Casement-Only 9.5 16. Casement-Slider 10.4 1 The certified cooling capacity is determined by the manufacturer in accordance with 10 CFR 429.15(a)(3). (2) The following standards apply to products manufactured starting May 26, 2026: Table 7 to Paragraph ( b )(2) Equipment class Combined energy efficiency ratio 1. Without reverse cycle, with louvered sides, and with a certified cooling capacity 1 less than 6,000 Btu/h 13.1 2. Without reverse cycle, with louvered sides and with a certified cooling capacity of 6,000 to 7,900 Btu/h 13.7 3. Without reverse cycle, with louvered sides and with a certified cooling capacity of 8,000 to 13,900 Btu/h 16.0 4. Without reverse cycle, with louvered sides and with a certified cooling capacity of 14,000 to 19,900 Btu/h 16.0 5a. Without reverse cycle, with louvered sides and with a certified cooling capacity of 20,000 Btu/h to 27,900 Btu/h 13.8 5b. Without reverse cycle, with louvered sides and with a certified cooling capacity of 28,000 Btu/h or more 13.2 6. Without reverse cycle, without louvered sides, and with a certified cooling capacity less than 6,000 Btu/h 12.8 7. Without reverse cycle, without louvered sides and with a certified cooling capacity of 6,000 to 7,900 Btu/h 12.8 8a. Without reverse cycle, without louvered sides and with a certified cooling capacity of 8,000 to 10,900 Btu/h 14.1 8b. Without reverse cycle, without louvered sides and with a certified cooling capacity of 11,000 to 13,900 Btu/h 13.9 9. Without reverse cycle, without louvered sides and with a certified cooling capacity of 14,000 to 19,900 Btu/h 13.7 10. Without reverse cycle, without louvered sides and with a certified cooling capacity of 20,000 Btu/h or more 13.8 11. With reverse cycle, with louvered sides, and with a certified cooling capacity less than 20,000 Btu/h 14.4 12. With reverse cycle, without louvered sides, and with a certified cooling capacity less than 14,000 Btu/h 13.7 13. With reverse cycle, with louvered sides, and with a certified cooling capacity of 20,000 Btu/h or more 13.7 14. With reverse cycle, without louvered sides, and with a certified cooling capacity of 14,000 Btu/h or more 12.8 15. Casement-Only 13.9 16. Casement-Slider 15.3 1 The certified cooling capacity is determined by the manufacturer in accordance with 10 CFR 429.15(a)(3). (c) Central air conditioners and heat pumps. The energy conservation standards defined in terms of the heating seasonal performance factor are based on Region IV, the minimum standardized design heating requirement, and the provisions of 10 CFR 429.16. (1) Central air conditioners and central air conditioning heat pumps manufactured on or after January 1, 2015, and before January 1, 2023, must have Seasonal Energy Efficiency Ratio and Heating Seasonal Performance Factor not less than: Product class Seasonal energy efficiency ratio (SEER) Heating seasonal performance factor (HSPF) (i) Split systems—air conditioners 13 (ii) Split systems—heat pumps 14 8.2 (iii) Single package units—air conditioners 14 (iv) Single package units—heat pumps 14 8.0 (v) Small-duct, high-velocity systems 12 7.2 (vi)(A) Space-constrained products—air conditioners 12 (vi)(B) Space-constrained products—heat pumps 12 7.4 (2) In addition to meeting the applicable requirements in paragraph (c)(1) of this section, products in product class (i) of paragraph (c)(1) of this section ( i.e., split-systems—air conditioners) that are installed on or after January 1, 2015, and before January 1, 2023, in the States of Alabama, Arkansas, Delaware, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, North Carolina, Oklahoma, South Carolina, Tennessee, Texas, or Virginia, or in the District of Columbia, must have a Seasonal Energy Efficiency Ratio (SEER) of 14 or higher. Any outdoor unit model that has a certified combination with a rating below 14 SEER cannot be installed in these States. The least efficient combination of each basic model must comply with this standard. (3)(i) In addition to meeting the applicable requirements in paragraph (c)(1) of this section, products in product classes (i) and (iii) of paragraph (c)(1) of this section ( i.e., split systems—air conditioners and single-package units—air conditioners) that are installed on or after January 1, 2015, and before January 1, 2023, in the States of Arizona, California, Nevada, or New Mexico must have a Seasonal Energy Efficiency Ratio (SEER) of 14 or higher and have an Energy Efficiency Ratio (EER) (at a standard rating of 95 °F dry bulb outdoor temperature) not less than the following: Product class Energy efficiency ratio (EER) (i) Split systems—air conditioners with rated cooling capacity less than 45,000 Btu/hr 12.2 (ii) Split systems—air conditioners with rated cooling capacity equal to or greater than 45,000 Btu/hr 11.7 (iii) Single-package units—air conditioners 11.0 (ii) Any outdoor unit model that has a certified combination with a rating below 14 SEER or the applicable EER cannot be installed in this region. The least-efficient combination of each basic model must comply with this standard. (4) Each basic model of single-package central air conditioners and central air conditioning heat pumps and each individual combination of split-system central air conditioners and central air conditioning heat pumps manufactured on or after January 1, 2015, shall have an average off mode electrical power consumption not more than the following: Product class Average off mode power consumption P W,OFF (watts) (i) Split-system air conditioners 30 (ii) Split-system heat pumps 33 (iii) Single-package air conditioners 30 (iv) Single-package heat pumps 33 (v) Small-duct, high-velocity systems 30 (vi) Space-constrained air conditioners 30 (vii) Space-constrained heat pumps 33 (5) Central air conditioners and central air conditioning heat pumps manufactured on or after January 1, 2023, must have a Seasonal Energy Efficiency Ratio 2 and a Heating Seasonal Performance Factor 2 not less than: Product class Seasonal energy efficiency ratio 2 (SEER2) Heating seasonal performance factor 2 (HSPF2) (i)(A) Split systems—air conditioners with a certified cooling capacity less than 45,000 Btu/hr 13.4 (i)(B) Split systems—air conditioners with a certified cooling capacity equal to or greater than 45,000 Btu/hr 13.4 (ii) Split systems—heat pumps 14.3 7.5 (iii) Single-package units—air conditioners 13.4 (iv) Single-package units—heat pumps 13.4 6.7 (v) Small-duct, high-velocity systems 12 6.1 (vi)(A) Space-constrained products—air conditioners 11.7 (vi)(B) Space-constrained products—heat pumps 11.9 6.3 (6)(i) In addition to meeting the applicable requirements in paragraph (c)(5) of this section, products in product classes (i) and (iii) of paragraph (c)(5) of this section ( i.e., split systems—air conditioners and single-package units—air conditioners) that are installed on or after January 1, 2023, in the southeast or southwest must have a Seasonal Energy Efficiency Ratio 2 and a Energy Efficiency Ratio 2 not less than: Product class Southeast * Southwest ** SEER2 SEER2 EER2 *** (i)(A) Split-systems—air conditioners with a certified cooling capacity less than 45,000 Btu/hr 14.3 14.3 11.7/9.8 † (i)(B) Split-systems—air conditioners with a certified cooling capacity equal to or greater than 45,000 Btu/hr 13.8 13.8 11.2/9.8 †† (iii) Single-package units—air conditioners 10.6 * “Southeast” includes the States of Alabama, Arkansas, Delaware, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, North Carolina, Oklahoma, Puerto Rico, South Carolina, Tennessee, Texas, Virginia, the District of Columbia, and the U.S. Territories. ** “Southwest” includes the States of Arizona, California, Nevada, and New Mexico. *** EER refers to the energy efficiency ratio at a standard rating of 95 °F dry bulb outdoor temperature. † The 11.7 EER2 standard applies to products with a certified SEER2 less than 15.2. The 9.8 EER2 standard applies to products with a certified SEER2 greater than or equal to 15.2. †† The 11.2 EER2 standard applies to products with a certified SEER2 less than 15.2. The 9.8 EER2 standard applies to products with a certified SEER2 greater than or equal to 15.2. (ii) Any model of outdoor unit that has a certified combination with a rating below the applicable standard level(s) for a region cannot be installed in that region. The least-efficient combination of each basic model, which for single-split-system air conditioner (AC) with single-stage or two-stage compressor (including space-constrained and small-duct high velocity systems (SDHV)) must be a coil-only combination, must comply with the applicable standard. See 10 CFR 429.16(a)(1) and (a)(4)(i). (d) Water Heaters. (1) The uniform energy factor of water heaters manufactured before May 6, 2029, shall not be less than the following: Product class Rated storage volume and input rating ( if applicable ) Draw pattern Uniform energy factor 1 Gas-fired Storage Water Heater ≥20 gal and ≤55 gal Very Small 0.3456 − (0.0020 × V r ) Low 0.5982 − (0.0019 × V r ) Medium 0.6483 − (0.0017 × V r ) High 0.6920 − (0.0013 × V r ) >55 gal and ≤100 gal Very Small 0.6470 − (0.0006 × V r ) Low 0.7689 − (0.0005 × V r ) Medium 0.7897 − (0.0004 × V r ) High 0.8072 − (0.0003 × V r ) Oil-fired Storage Water Heater ≤50 gal Very Small 0.2509 − (0.0012 × V r ) Low 0.5330 − (0.0016 × V r ) Medium 0.6078 − (0.0016 × V r ) High 0.6815 − (0.0014 × V r ) Electric Storage Water Heaters ≥20 gal and ≤55 gal Very Small 0.8808 − (0.0008 × V r ) Low 0.9254 − (0.0003 × V r ) Medium 0.9307 − (0.0002 × V r ) High 0.9349 − (0.0001 × V r ) >55 gal and ≤120 gal Very Small 1.9236 − (0.0011 × V r ) Low 2.0440 − (0.0011 × V r ) Medium 2.1171 − (0.0011 × V r ) High 2.2418 − (0.0011 × V r ) Tabletop Water Heater ≥20 gal and ≤120 gal Very Small 0.6323 − (0.0058 × V r ) Low 0.9188 − (0.0031 × V r ) Medium 0.9577 − (0.0023 × V r ) High 0.9884 − (0.0016 × V r ) Instantaneous Gas-fired Water Heater <2 gal and >50,000 Btu/h Very Small 0.80 Low 0.81 Medium 0.81 High 0.81 Instantaneous Electric Water Heater <2 gal Very Small 0.91 Low 0.91 Medium 0.91 High 0.92 Grid-enabled Water Heater >75 gal Very Small 1.0136 − (0.0028 × V r ) Low 0.9984 − (0.0014 × V r ) Medium 0.9853 − (0.0010 × V r ) High 0.9720 − (0.0007 × V r ) 1 V r is the rated storage volume (in gallons), as determined pursuant to § 429.17 of this chapter. (2) The uniform energy factor of water heaters manufactured on or after May 6, 2029, shall not be less than the following: Table 14 to Paragraph (d)(2) Product class Effective storage volume and input rating (if applicable) Draw pattern Uniform energy factor * Gas-fired Storage Water Heater <20 gal Very Small 0.2062−(0.0020 × V eff ) Low 0.4893−(0.0027 × V eff ) Medium 0.5758−(0.0023 × V eff ) High 0.6586−(0.0020 × V eff ) ≥20 gal and ≤55 gal Very Small 0.3925−(0.0020 × V eff ) Low 0.6451−(0.0019 × V eff ) Medium 0.7046−(0.0017 × V eff ) High 0.7424−(0.0013 × V eff ) >55 gal and ≤100 gal Very Small 0.6470−(0.0006 × V eff ) Low 0.7689−(0.0005 × V eff ) Medium 0.7897−(0.0004 × V eff ) High 0.8072−(0.0003 × V eff ) >100 gal Very Small 0.1482−(0.0007 × V eff ) Low 0.4342−(0.0017 × V eff ) Medium 0.5596−(0.0020 × V eff ) High 0.6658−(0.0019 × V eff ) Oil-fired Storage Water Heater ≤50 gal Very Small 0.2909−(0.0012 × V eff ) Low 0.5730−(0.0016 × V eff ) Medium 0.6478−(0.0016 × V eff ) High 0.7215−(0.0014 × V eff ) >50 gal Very Small 0.1580−(0.0009 × V eff ) Low 0.4390−(0.0020 × V eff ) Medium 0.5389−(0.0021 × V eff ) High 0.6172−(0.0018 × V eff ) Very Small Electric Storage Water Heater <20 gal Very Small 0.5925−(0.0059 × V eff ) Low 0.8642−(0.0030 × V eff ) Medium 0.9096−(0.0020 × V eff ) High 0.9430−(0.0012 × V eff ) Small Electric Storage Water Heater ≥20 gal and ≤35 gal Very Small 0.8808−(0.0008 × V eff ) Low 0.9254−(0.0003 × V eff ) Electric Storage Water Heaters ≥20 and ≤55 gal (excluding small electric storage water heaters) Very Small 2.30 Low 2.30 Medium 2.30 High 2.30 >55 gal and ≤120 gal Very Small 2.50 Low 2.50 Medium 2.50 High 2.50 >120 gal Very Small 0.3574−(0.0012 × V eff ) Low 0.7897−(0.0019 × V eff ) Medium 0.8884−(0.0017 × V eff ) High 0.9575−(0.0013 × V eff ) Tabletop Water Heater <20 gal Very Small 0.5925−(0.0059 × V eff ) Low 0.8642−(0.0030 × V eff ) ≥20 gal Very Small 0.6323−(0.0058 × V eff ) Low 0.9188−(0.0031 × V eff ) Instantaneous Oil-fired Water Heater <2 gal and ≤210,000 Btu/h Very Small 0.61 Low 0.61 Medium 0.61 High 0.61 ≥2 gal and ≤210,000 Btu/h Very Small 0.2780−(0.0022 × V eff ) Low 0.5151−(0.0023 × V eff ) Medium 0.5687−(0.0021 × V eff ) High 0.6147−(0.0017 × V eff ) Instantaneous Electric Water Heater <2 gal Very Small 0.91 Low 0.91 Medium 0.91 High 0.92 ≥2 gal Very Small 0.8086−(0.0050 × V eff ) Low 0.9123−(0.0020 × V eff ) Medium 0.9252−(0.0015 × V eff ) High 0.9350−(0.0011 × V eff ) Grid-Enabled Water Heater >75 gal Very Small 1.0136−(0.0028 × V eff ) Low 0.9984−(0.0014 × V eff ) Medium 0.9853−(0.0010 × V eff ) High 0.9720−(0.0007 × V eff ) * V eff is the Effective Storage Volume (in gallons), as determined pursuant to § 429.17 of this chapter. (3) The provisions of paragraph (d) of this section are separate and severable from one another. Should a court of competent jurisdiction hold any provision(s) of paragraph (d) of this section to be stayed or invalid, such action shall not affect any other provision of paragraph (d) of this section. (e) Furnaces and boilers —(1) Furnaces. (i) The Annual Fuel Utilization Efficiency (AFUE) of residential furnaces shall not be less than the following for non-weatherized gas furnaces manufactured before November 19, 2015, non-weatherized oil furnaces manufactured before May 1, 2013, and weatherized furnaces manufactured before January 1, 2015: Product class AFUE (percent) 1 (A) Furnaces (excluding classes noted below) 78 (B) Mobile Home furnaces 75 (C) Small furnaces (other than those designed solely for installation in mobile homes) having an input rate of less than 45,000 Btu/hr ( 1 ) Weatherized (outdoor) 78 ( 2 ) Non-weatherized (indoor) 78 1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2) of this part. (ii) The AFUE for non-weatherized gas furnaces (not including mobile home gas furnaces) manufactured on or after November 19, 2015, but before December 18, 2028; mobile home gas furnaces manufactured on or after November 19, 2015, but before December 18, 2028; non-weatherized oil-fired furnaces (not including mobile home furnaces) manufactured on or after May 1, 2013, mobile home oil-fired furnaces manufactured on or after September 1, 1990; weatherized gas-fired furnaces manufactured on or after January 1, 2015; weatherized oil-fired furnaces manufactured on or after January 1, 1992; and electric furnaces manufactured on or after January 1, 1992; shall not be less than the following: Product class AFUE (percent) 1 (A) Non-weatherized gas furnaces (not including mobile home furnaces) 80.0 (B) Mobile home gas furnaces 80.0 (C) Non-weatherized oil-fired furnaces (not including mobile home furnaces) 83.0 (D) Mobile home oil-fired furnaces 75.0 (E) Weatherized gas furnaces 81.0 (F) Weatherized oil-fired furnaces 78.0 (G) Electric furnaces 78.0 1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2). (iii) The AFUE for non-weatherized gas (not including mobile home gas furnaces) manufactured on and after December 18, 2028; and mobile home gas furnaces manufactured on and after December 18, 2028, shall not be less than the following: Product class AFUE (percent) 1 (A) Non-weatherized gas furnaces (not including mobile home gas furnaces) 95.0 (B) Mobile home gas furnaces 95.0 1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2). (iv) Furnaces manufactured on or after May 1, 2013, shall have an electrical standby mode power consumption (P W,SB ) and electrical off mode power consumption (P W,OFF ) not more than the following: Product class Maximum standby mode electrical power consumption, P W,SB (watts) Maximum off mode electrical power consumption, P W,OFF (watts) (A) Non-weatherized oil-fired furnaces (including mobile home furnaces) 11 11 (B) Electric furnaces 10 10 (2) Boilers. (i) The AFUE of residential boilers manufactured before September 1, 2012, shall not be less than the following: Product class AFUE 1 (percent) (A) Boilers (excluding gas steam) 80 (B) Gas steam boilers 75 1 Annual Fuel Utilization Efficiency, as determined in § 430.22(n)(2) of this part. (ii) Except as provided in paragraph (e)(2)(iv) of this section, the AFUE of residential boilers, manufactured on or after September 1, 2012, and before January 15, 2021, shall not be less than the following and must comply with the design requirements as follows: Product class AFUE 1 (percent) Design requirements (A) Gas-fired hot water boiler 82 Constant burning pilot not permitted. Automatic means for adjusting water temperature required (except for boilers equipped with tankless domestic water heating coils). (B) Gas-fired steam boiler 80 Constant burning pilot not permitted. (C) Oil-fired hot water boiler 84 Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils). (D) Oil-fired steam boiler 82 None. (E) Electric hot water boiler None Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils). 1 Annual Fuel Utilization Efficiency, as determined in § 430.22(n)(2) of this part. (iii)(A) Except as provided in paragraph (e)(2)(v) of this section, the AFUE of residential boilers, manufactured on and after January 15, 2021, shall not be less than the following and must comply with the design requirements as follows: Product class AFUE 1 (percent) Design requirements ( 1 ) Gas-fired hot water boiler 84 Constant-burning pilot not permitted. Automatic means for adjusting water temperature required (except for boilers equipped with tankless domestic water heating coils). ( 2 ) Gas-fired steam boiler 82 Constant-burning pilot not permitted. ( 3 ) Oil-fired hot water boiler 86 Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils). ( 4 ) Oil-fired steam boiler 85 None. ( 5 ) Electric hot water boiler None Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils). ( 6 ) Electric steam boiler None None. 1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2) of this part. (B) Except as provided in paragraph (e)(2)(v) of this section, the standby mode power consumption (P W,SB ) and off mode power consumption (P W,OFF ) of residential boilers, manufactured on and after January 15, 2021, shall not be more than the following: Product class P W,SB (watts) P W,OFF (watts) ( 1 ) Gas-fired hot water boiler 9 9 ( 2 ) Gas-fired steam boiler 8 8 ( 3 ) Oil-fired hot water boiler 11 11 ( 4 ) Oil-fired steam boiler 11 11 ( 5 ) Electric hot water boiler 8 8 ( 6 ) Electric steam boiler 8 8 (iv) Automatic means for adjusting water temperature. (A) The automatic means for adjusting water temperature as required under paragraph (e)(2)(ii) of this section must automatically adjust the temperature of the water supplied by the boiler to ensure that an incremental change in inferred heat load produces a corresponding incremental change in the temperature of water supplied. (B) For boilers that fire at a single input rate, the automatic means for adjusting water temperature requirement may be satisfied by providing an automatic means that allows the burner or heating element to fire only when the means has determined that the inferred heat load cannot be met by the residual heat of the water in the system. (C) When there is no inferred heat load with respect to a hot water boiler, the automatic means described in this paragraph shall limit the temperature of the water in the boiler to not more than 140 degrees Fahrenheit. (D) A boiler for which an automatic means for adjusting water temperature is required shall be operable only when the automatic means is installed. (v) A boiler that is manufactured to operate without any need for electricity or any electric connection, electric gauges, electric pumps, electric wires, or electric devices is not required to meet the AFUE or design requirements applicable to the boiler requirements of paragraph (e)(2)(ii) of this section, but must meet the requirements of paragraph (e)(2)(i) of this section, as applicable. (f) Dishwashers. (1) All dishwashers manufactured on or after May 30, 2013, shall meet the following standard— (i) Standard size dishwashers shall not exceed 307 kwh/year and 5.0 gallons per cycle. Standard size dishwashers have a capacity equal to or greater than eight place settings plus six serving pieces as specified in AHAM DW-1-2020 (incorporated by reference, see § 430.3) using the test load specified in section 2.3 of appendix C1 or section 2.4 of appendix C2 to subpart B of this part, as applicable. (ii) Compact size dishwashers shall not exceed 222 kwh/year and 3.5 gallons per cycle. Compact size dishwashers have a capacity less than eight place settings plus six serving pieces as specified in AHAM DW-1-2020 (incorporated by reference, see § 430.3) using the test load specified in section 2.3 of appendix C1 or section 2.4 of appendix C2 to subpart B of this part, as applicable. (2) All dishwashers manufactured on or after April 23, 2027, shall not exceed the following standard— Product class Estimated annual energy use (kWh/year) Maximum per-cycle water consumption (gal/cycle) (i) Standard-size 1 (≥8 place settings plus 6 serving pieces) 2 223 3.3 (ii) Compact-size (<8 place settings plus 6 serving pieces) 2 174 3.1 1 The energy conservation standards in this table do not apply to standard-size dishwashers with a cycle time for the normal cycle of 60 minutes or less. 2 Place settings are as specified in AHAM DW-1-2020 (incorporated by reference, see § 430.3) and the test load is as specified in section 2.4 of appendix C2 to subpart B of this part. (3) The provisions of paragraph (f)(2) of this section are separate and severable from one another. Should a court of competent jurisdiction hold any provision(s) of this section to be stayed or invalid, such action shall not affect any other provision of this section. (g) Clothes washers. (1) Clothes washers manufactured on or after January 1, 2018, shall have an Integrated Modified Energy Factor no less than, and an Integrated Water Factor no greater than: Product class Integrated modified energy factor (cu.ft./kWh/cycle) Integrated water factor (gal/cycle/cu.ft.) (i) Top-loading, Compact (less than 1.6 ft 3 capacity) 1.15 12.0 (ii) Top-loading, Standard (1.6 ft 3 or greater capacity) 1.57 6.5 (iii) Front-loading, Compact (less than 1.6 ft 3 capacity) 1.13 8.3 (iv) Front-loading, Standard (1.6 ft 3 or greater capacity) 1.84 4.7 (2) Clothes washers manufactured on or after March 1, 2028: (i) Shall have an Energy Efficiency Ratio and a Water Efficiency Ratio no less than: Product class Energy efficiency ratio (lb/kWh/cycle) Water efficiency ratio (lb/gal/cycle) (A) Automatic Clothes Washers: ( 1 ) Top-Loading Ultra-Compact (less than 1.6 ft 3 capacity) 3.79 0.29 ( 2 ) Top-Loading Standard-Size (1.6 ft 3 or greater capacity) 1 4.27 0.57 ( 3 ) Front-Loading Compact (less than 3.0 ft 3 capacity) 2 5.02 0.71 ( 4 ) Front-Loading Standard-Size (3.0 ft 3 or greater capacity) 3 5.52 0.77 (B) Semi-Automatic Clothes Washers 2.12 0.27 1 The energy conservation standards in this table do not apply to top-loading standard-size clothes washers with an average cycle time less than 30 minutes. 2 The energy conservation standards in this table do not apply to front-loading clothes washers with a capacity greater than or equal to 1.6 ft 3 and less than 3.0 ft 3 with an average cycle time of less than 45 minutes. 3 The energy conservation standards in this table do not apply to front-loading standard-size clothes washers with an average cycle time less than 45 minutes. (ii) The provisions of this paragraph (g)(2) are separate and severable from one another. Should a court of competent jurisdiction hold any provision(s) of this section to be stayed or invalid, such action shall not affect any other provisions of this section. (h) Clothes dryers. (1) Gas clothes dryers manufactured after January 1, 1988 shall not be equipped with a constant burning pilot. (2) Clothes dryers manufactured on or after May 14, 1994 and before January 1, 2015, shall have an energy factor no less than: Product class Energy factor (lbs/kWh) i. Electric, Standard (4.4 ft 3 or greater capacity) 3.01 ii. Electric, Compact (120V) (less than 4.4 ft 3 capacity) 3.13 iii. Electric, Compact (240V) (less than 4.4 ft 3 capacity) 2.90 iv. Gas 2.67 (3) Clothes dryers manufactured on or after January 1, 2015, shall have a combined energy factor no less than: Product class Combined energy factor (lbs/kWh) (i) Vented Electric, Standard (4.4 ft 3 or greater capacity) 3.73 (ii) Vented Electric, Compact (120V) (less than 4.4 ft 3 capacity) 3.61 (iii) Vented Electric, Compact (240V) (less than 4.4 ft 3 capacity) 3.27 (iv) Vented Gas 3.30 (v) Ventless Electric, Compact (240V) (less than 4.4 ft 3 capacity) 2.55 (vi) Ventless Electric, Combination Washer-Dryer 2.08 (4) Clothes dryers manufactured on or after March 1, 2028, shall have a combined energy factor, determined in accordance with appendix D2 of this subpart, no less than: Product class CEF D2 (lb/kWh) (i) Electric, Standard (4.4 ft 3 or greater capacity) * 3.93 (ii) Electric, Compact (120V) (less than 4.4 ft 3 capacity) 4.33 (iii) Vented Electric, Compact (240V) (less than 4.4 ft 3 capacity) 3.57 (iv) Vented Gas, Standard (4.4 ft 3 or greater capacity) ** 3.48 (v) Vented Gas, Compact (less than 4.4 ft 3 capacity) 2.02 (vi) Ventless Electric, Compact (240V) (less than 4.4 ft 3 capacity) 2.68 (vii) Ventless Electric, Combination Washer-Dryer 2.33 * The energy conservation standards in this product class do not apply to Vented Electric, Standard clothes dryers with a cycle time of less than 30 minutes, when tested according to appendix D2 in subpart B of this part. ** The energy conservation standards in this product class do not apply to Vented Gas, Standard clothes dryers with a cycle time of less than 30 minutes, when tested according to appendix D2 in subpart B of this part. (i) Direct heating equipment. (1) Vented home heating equipment manufactured on or after January 1, 1990 and before April 16, 2013, shall have an annual fuel utilization efficiency no less than: Product class Annual fuel utilization efficiency, Jan. 1, 1990 (percent) 1. Gas wall fan type up to 42,000 Btu/h 73 2. Gas wall fan type over 42,000 Btu/h 74 3. Gas wall gravity type up to 10,000 Btu/h 59 4. Gas wall gravity type over 10,000 Btu/h up to 12, 000 Btu/h 60 5. Gas wall gravity type over 12,000 Btu/h up to 15,000 Btu/h 61 6. Gas wall gravity type over 15,000 Btu/h up to 19,000 Btu/h 62 7. Gas wall gravity type over 19,000 Btu/h and up to 27,000 Btu/h 63 8. Gas wall gravity type over 27,000 Btu/h and up to 46,000 Btu/h 64 9. Gas wall gravity type over 46,000 Btu/h 65 10. Gas floor up to 37,000 Btu/h 56 11. Gas floor over 37,000 Btu/h 57 12. Gas room up to 18,000 Btu/h 57 13. Gas room over 18,000 Btu/h up to 20,000 Btu/h 58 14. Gas room over 20,000 Btu/h up to 27,000 Btu/h 63 15. Gas room over 27,000 Btu/h up to 46,000 Btu/h 64 16. Gas room over 46,000 Btu/h 65 (2) Vented home heating equipment manufactured on or after April 16, 2013, shall have an annual fuel utilization efficiency no less than: Product class Annual fuel utilization efficiency, April 16, 2013 (percent) Gas wall fan type up to 42,000 Btu/h 75 Gas wall fan type over 42,000 Btu/h 76 Gas wall gravity type up to 27,000 Btu/h 65 Gas wall gravity type over 27,000 Btu/h up to 46,000 Btu/h 66 Gas wall gravity type over 46,000 Btu/h 67 Gas floor up to 37,000 Btu/h 57 Gas floor over 37,000 Btu/h 58 Gas room up to 20,000 Btu/h 61 Gas room over 20,000 Btu/h up to 27,000 Btu/h 66 Gas room over 27,000 Btu/h up to 46,000 Btu/h 67 Gas room over 46,000 Btu/h 68 (j) Cooking Products (1) Conventional cooking tops. (i) Gas cooking tops, other than gas portable indoor conventional cooking tops, manufactured on or after April 9, 2012, and before January 31, 2028, shall not be equipped with a constant burning pilot light. (ii) Gas portable indoor conventional cooking tops, manufactured on or after April 9, 2012, shall not be equipped with a constant burning pilot light. (iii) Conventional cooking tops, other than portable indoor conventional cooking tops, manufactured on or after January 31, 2028, shall have an integrated annual energy consumption (IAEC), excluding any downdraft venting system energy consumption, no greater than: Product class Maximum integrated annual energy consumption (IAEC) (A) Electric Smooth Element Standalone Cooking Tops 207 kWh/year. (B) Electric Smooth Element Cooking Top Component of Combined Cooking Products 207 kWh/year. (C) Gas Standalone Cooking Tops 1,770 kBtu/year. (D) Gas Cooking Top Component of Combined Cooking Products 1,770 kBtu/year. (2) Conventional ovens. The control system of a conventional oven shall: (i) Not be equipped with a constant burning pilot light, for gas ovens manufactured on or after April 9, 2012; and (ii) Not be equipped with a linear power supply, for electric and gas ovens manufactured on or after January 31, 2028. (3) Microwave ovens. (i) Microwave-only ovens and countertop convection microwave ovens manufactured on or after June 17, 2016, and before June 22, 2026, shall have an average standby power not more than 1.0 watt. Built-in and over-the-range convection microwave ovens manufactured on or after June 17, 2016, and before June 22, 2026, shall have an average standby power not more than 2.2 watts. (ii) Microwave-only ovens and countertop convection microwave ovens manufactured on or after June 22, 2026, shall have an average standby power not more than 0.6 watts. Built-in and over-the-range convection microwave ovens manufactured on or after June 22, 2026, shall have an average standby power not more than 1.0 watt. (k) Pool heaters. (1) Gas-fired pool heaters manufactured on and after April 16, 2013 and before May 30, 2028, shall have a thermal efficiency not less than 82%. (2) Gas-fired pool heaters and electric pool heaters manufactured on and after May 30, 2028, shall have an integrated thermal efficiency not less than the following: where Q IN is the certified input capacity of a gas-fired pool heater basic model, in Btu/h, and PE is the certified active electrical power of an electric pool heater, in Btu/h. (l) Television sets. [Reserved] (m) Fluorescent lamp ballasts —(1) Standards for fluorescent lamp ballasts (other than dimming ballasts). Except as provided in paragraphs (m)(2) and (3) of this section, each fluorescent lamp ballast manufactured on or after November 14, 2014, (i) Designed and marke…

    Related guides, FAQ and contract templates