Beta
10 CFR § 429.40
10 CFR § 429.40 — § 429.40 Candelabra base incandescent lamps and intermediate base incandescent lamps.
Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.
Analyze this law with AI§ 429.40 Candelabra base incandescent lamps and intermediate base incandescent lamps.
(a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to candelabra base incandescent lamps; and
(2) For each basic model of candelabra base incandescent lamp and intermediate base incandescent lamp, a minimum sample of 21 lamps shall be randomly selected and tested. Any represented value of lamp wattage of a basic model shall be based on the sample and shall be less than or equal to the lower of:
(i) The mean of the sample, where:
Or,
(ii) The lower 97.5 percent confidence limit (LCL) of the true mean divided by 0.95, where:
(b) Certification reports. (1) The requirements of § 429.12 are applicable to candelabra base and intermediate base incandescent lamps; and
(2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information:
(i) Candelabra base incandescent lamp: The rated wattage in watts (W).
(ii) Intermediate base incandescent lamp: The rated wattage in watts (W).
[76 FR 12451, Mar. 7, 2011; 76 FR 24774, May 2, 2011]