Beta
HK Cap. 123I
HK Cap. 123I — Building (Standards of Sanitary Fitments, Plumbing, Drainage Works and Latrines) Regulations
Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.
Analyze this law with AIBuilding (Standards of Sanitary Fitments, Plumbing, Drainage Works and Latrines)
Regulations ( Cap. 123, section
38 ) [1 January 1960] (Format changes— E.R. 3 of 2020 ) Part
I Preliminary 1. Citation These regulations may be cited as the Building (Standards of Sanitary Fitments, Plumbing, Drainage Works and Latrines) Regulations. 2. Interpretation
In these regulations, unless the context otherwise requires—
anti-syphonage
pipe
( 反虹吸管 ) means a pipe used or constructed to be
used for the purpose of preventing loss of water seal from the trap of a soil fitment or
waste fitment;
approved
( 批准 ) means approved by the Building
Authority;
cesspool
( 污水池 ) means an underground chamber constructed to
be used for the reception and storage of foul water;
chemical
closet
fitment
( 化學處理廁所設備 ) means a latrine fitment in which the
contents of the receptacle for excrement are treated by means of chemicals;
cleaning
eye
( 清理孔 ) means an access opening in a pipe;
foul
water
( 髒水 ) means any water contaminated by soil, waste
or trade effluent;
latrine
( 廁所 ) means a room used or intended to be used for
the housing of latrine fitments;
latrine
fitment
( 廁所設備 ) means a fitment containing a receptacle
for excrement, which is removable;
manhole
( 沙井 ) means a chamber constructed on a drain or
sewer to provide access thereto for inspection, testing and the clearance of
obstructions;
nullah
( 大溝渠 ) includes any trained streamcourse;
private
sewer
( 私家污水渠 ) means a sewer which is not a public
sewer;
public
channel
( 公共渠道 ) means a channel vested in and maintained
by the Government;
public
sewer
( 公共污水渠 ) means a sewer vested in and maintained by
the Government;
rain
water
pipe
( 雨水管 ) means a pipe used or constructed to be used
for carrying off surface water directly from roof surfaces, verandahs and
balconies;
septic
tank
( 化糞池 ) means a tank, for the reception of soil and
waste from a building, in which the liquification of solid organic matter occurs;
( L.N. 361 of
1980 )
slop
sink
( 污水盆 ) means a sink used or constructed to be used
for receiving solid or liquid excrement;
sludge
( 污泥 ) means the layer of material settled to the
bottom of a septic tank where reduction by anaerobic decomposition occurs;
( L.N. 361 of
1980 )
soil
( 便溺污水 ) means the discharge from a soil
fitment;
soil
fitment
( 便溺污水設備 ) means a watercloset fitment, trough
watercloset, urinal, slop sink, bidet or any similar fitment;
soil
pipe
( 便溺污水管 ) means a pipe used or constructed to be
used for carrying off soil;
sub-soil
water
( 地下水 ) means water occurring naturally below the
surface of the ground;
surface
water
( 地面水 ) means rain water from any part of a
building including any paved area or ground, whether paved or not, appurtenant to any
building;
trade
effluent
( 工商業污水 ) means any liquid, either with or without
particles of matter in suspension therein, which is wholly or in part produced in the
course of any trade or industry;
waste
( 廢水 ) means used water from a waste fitment or
similar fitment;
waste
fitment
( 廢水設備 ) means a bath, lavatory basin or sink,
other than a slop sink;
waste
pipe
( 廢水管 ) means a pipe used or constructed to be used
for carrying off waste;
water
authority
( 水務監督 ) and
waterworks
( 水務設施 ) have the meaning assigned to them by
section 2 of the Waterworks Ordinance ( Cap.
102 ).
( L.N. 62 of
1966 ) (L.N. 191 of 2015 ) Part
II Standards
of
Sanitary
Fitments 3. Interpretation of Part II
In the regulations in this Part, unless the context otherwise requires—
cinema
( 電影院 ) means a building or part of a building which is
designed for cinematographic displays; ( L.N. 191
of 2015 )
department store
( 百貨公司 ) has the meaning given by section 2 of
Schedule 1 to the Fire Safety (Commercial Premises) Ordinance ( Cap. 502 ); ( L.N. 191
of 2015 )
factory
( 工廠 ) has the meaning given by section 2(1) of
the Factories and Industrial Undertakings Ordinance ( Cap.
59 ); ( L.N. 191 of
2015 )
food room
( 食物室 ) has the meaning given by section 3(1)
of the Food Business Regulation ( Cap. 132 sub. leg. X );
( L.N. 191 of
2015 )
funeral parlour
( 殯儀館 ) means a building or part of a building which is
designed for performing funeral services; ( L.N.
191 of 2015 )
industrial undertaking
( 工業經營 )—
(a) has the meaning given by section 2(1) of the Factories and
Industrial Undertakings Ordinance ( Cap. 59 );
but
(b) does not include a food room of a restaurant; ( L.N. 191 of 2015 )
place of public entertainment
( 公眾娛樂場所 )—
(a) has the meaning given by section 2 of the Places of Public
Entertainment Ordinance ( Cap. 172 ); but
(b) does not include a sports stadium or cinema; ( L.N. 191 of 2015 )
religious institution
( 宗教機構 )—
(a) means a building or part of a building which is designed for holding
services or saying prayers by congregations loyal to a belief in accordance with
the practice of religious principles; and
(b) includes a place referred to in paragraph (b) of the definition of
Chinese temple in section 2 of the Chinese Temples
Ordinance ( Cap. 153 ); ( L.N. 191 of 2015 )
residential
building
( 住宅建築物 ) means a domestic building, but does not
include any hostel, dormitory or other room or premises provided for housing or lodging
some or all of the pupils of any school out of school hours, whether such hostel
dormitory or other room or premises is in or is part of the same building or group of
buildings as the classrooms in the school or not;
( 73 of 1983 s.
3 )
restaurant
( 食肆 ) has the meaning given by section 31(2)
of the Food Business Regulation ( Cap. 132 sub. leg. X );
( L.N. 191 of
2015 )
school
( 學校 ) has the meaning assigned to it by
section 3
of the Education Ordinance ( Cap.
279 );
shopping arcade
( 商場 ) includes the passageways connecting the shops that
form the arcade; ( L.N. 191 of
2015 )
sports stadium
( 體育場 ) means a building or part of a building which is
designed for sporting activities; ( L.N. 191 of
2015 )
tenement
house
( 唐樓 ) means a building in the domestic part of
which any living room is intended or adapted for the use of more than one tenant or
sub-tenant;
usable floor area
( 實用樓面面積 ), except in regulation 7A(3)(a) ,
in relation to a building—
(a) means the aggregate of the areas of the floors in the building;
but
(b)
does not include— (i) any staircase, public circulation space, lift landing, kitchen in a
self-contained flat or lavatory in the building; or (ii) any space occupied by machinery for a lift, or for the air-conditioning
or utility system or any other similar service, provided for the building;
( L.N. 191 of
2015 )
workplace
( 工作地點 ) means—
(a) an office;
(b) an industrial undertaking;
(c) a shop that is neither within a shopping arcade nor within a department
store; or
(d) a food room of a restaurant, where the number of persons in the restaurant
(determined in accordance with regulation 8(2)(a)) is more than 300.
( L.N. 191 of
2015 )
( L.N. 196 of
1996 ; L.N. 191 of 2015 ) 4. Residential buildings
(1)
Save as provided in paragraph (2), in every residential building—
(a) where separate waterclosets are not provided for male persons and for
female persons, the number of watercloset fitments provided
must
be not less than the number specified in Table 1;
(b)
where separate waterclosets are provided for male persons and for female
persons,
the number of watercloset
fitments
provided for—
( L.N. 191 of
2015 ) (i) male persons must be not less than the number specified in Part 1 of
Table 2; and (ii) female persons must be not less than the number specified in Part 2 of
Table 2;
(c) where separate waterclosets are provided for male persons and for female
persons and urinals are installed for the use of male persons, the number of
watercloset fitments and urinals
provided
for male persons must be not less than the number specified in Table 3;
and
(d) the number of lavatory basins, and baths or showers, provided must be not
less than the number specified in Table 4.
Table 1
Number of
Watercloset Fitments (where Separate Waterclosets are Not
Provided for Male Persons and for Female Persons in Residential
Building)
Column
1
Column
2
Number
of persons
in
residential
building
Number
of watercloset fitments
1.
Not more than 8
1
2.
More than 8
1 plus 1 for every 12 persons, or part of
those persons, over 8
( L.N. 191 of
2015 )
Table 2
Number of
Watercloset Fitments (where Separate Waterclosets are
Provided for Male Persons and for Female Persons in
Residential Building)
Part 1
Number of
Watercloset Fitments Provided for Male Persons in
Residential Building
Column 1
Column 2
Number of male persons in residential building
Number of watercloset fitments
1.
Not more than 8
1
2.
More than 8
1 plus 1 for every 12 male persons, or
part of those persons, over 8
Part 2
Number of
Watercloset Fitments Provided for Female Persons in
Residential Building
Column 1
Column 2
Number of female persons in residential building
Number of watercloset fitments
1.
Not more than 8
1
2.
More than 8
1 plus 1 for every 12 female persons, or
part of those persons, over 8
( L.N. 191 of
2015 )
Table 3
Number of
Watercloset Fitments and Urinals Provided for Male Persons
in Residential Building
Column 1
Column 2
Column 3
Number of male persons in residential building
Number of watercloset fitments
Number of urinals
1.
Not more than 12
1
1
2.
More than 12
1 plus 1 for every 12 male persons, or part of those persons,
over 12
1 plus 1 for every 12 male persons, or part of those persons,
over 12
( L.N. 191 of
2015 )
Table 4
Number of
Lavatory Basins and Baths or Showers Provided in Residential
Building
Column 1
Column 2
Column 3
Number of persons
in residential
building
Number of lavatory basins
Number of baths or showers
1.
Not more
than 8
1
1
2.
More than 8
1 plus 1 for every 12 persons, or part of those persons, over
8
1 plus 1 for every 12 persons, or part of those persons, over
8
( L.N. 191 of
2015 )
(2)
(a) For
a tenement house, water supply points may, subject to the provisions of
subparagraphs
(b) and (c), be provided in lieu of lavatory basins and baths or showers and,
for the purposes of paragraph (1)(d) , the provision of one water
supply point shall be deemed
to be
the provision of
one
lavatory basin and one bath or shower.
(b) The number of water supply points so provided shall be not less than the
number of lavatory basins required, by paragraph (1)(d) , to be
provided in the tenement house.
(c) Such water supply points shall be provided in a separate compartment, not
less than
0.75
m 2 in area, or in a watercloset.
( L.N. 294 of
1976 )
(d) For the purposes of this paragraph, any supply of water provided for a sink
in any kitchen shall not be a water supply point.
(3) The watercloset fitments or the watercloset fitments and urinals, as the case
may be, provided in any residential building in accordance with the provisions of
paragraph (1), and, where, in accordance with regulation 9 , latrine
fitments or latrine fitments and bucket urinals, as the case may be, are provided in
any residential building, the same shall be situated in the building to the
satisfaction of the Building Authority.
(4)
For the purposes of this regulation—
(a)
the number of persons in a residential building is to be
determined— (i) for a tenement house, dormitory, barrack or boarding house—at the rate
of 1 person for every 3 m 2 of the usable floor area of the
tenement house, dormitory, barrack or boarding house, as the case may be;
or (ii) for any other residential building—at the rate of 1 person for every 9
m 2 of the usable floor area of the building; and
( L.N. 191 of
2015 )
(b) where separate waterclosets are provided for male persons and for female
persons
in a residential building, the proportion of male persons to female persons in
the building is, unless the Building Authority is satisfied
that the proportion is or will be
otherwise,
deemed to be 1:1. ( L.N. 191 of 2015 ) 5. Workplaces ( L.N. 191 of 2015 )
(1)
Save as provided in paragraph (3), in every workplace—
( L.N. 191 of
2015 )
(a) the number of watercloset fitments and urinals provided for male persons
must
be not less than the number specified in Table 5;
(b) the number of watercloset fitments provided for female persons
must
be not less than the number specified in Table 6;
and
(c)
the number of lavatory
basins
provided for— ( L.N. 191 of
2015 ) (i) male persons must be not less than the number specified in Part 1 of
Table 7; and (ii) female persons must be not less than the number specified in Part 2 of
Table 7.
Table 5
Number of
Watercloset Fitments and Urinals Provided for Male Persons
in Workplace
Column 1
Column 2
Column 3
Number of male
persons in
workplace
Number of watercloset fitments
Number of
urinals
1.
Not more
than 10
1
Nil
2.
11–100
1 for every 25 male persons or part of those persons
1 for every 50 male persons or part of those persons
3.
More than 100
4 plus 1 for every 50 male persons, or part of those persons,
over 100
2 plus 1 for every 50 male persons, or part of those persons,
over 100
( L.N. 191 of
2015 )
Table 6
Number of
Watercloset Fitments Provided for Female Persons in
Workplace
Column 1
Column 2
Number of female persons in workplace
Number of watercloset fitments
1.
Not more than 10
1
2.
11–25
2
3.
More than 25
2 plus 1 for every 25 female persons, or
part of those persons, over 25
( L.N. 191 of
2015 )
Table 7
Number of
Lavatory Basins Provided in Workplace
Part 1
Number of
Lavatory Basins Provided for Male Persons in Workplace
Column 1
Column 2
Number of male persons
in workplace
Number of lavatory basins
1.
Not more than 100
1 for every 25 male persons or part of those persons
2.
More than 100
4 plus 1 for every
50 male persons, or part of those persons, over 100
Part 2
Number of
Lavatory Basins Provided for Female Persons in
Workplace
Column 1
Column 2
Number of female persons
in workplace
Number of lavatory basins
1.
Not more than 100
1 for every 25 female persons or part of
those persons
2.
More than 100
4 plus 1 for every 50 female persons, or
part of those persons, over 100
( L.N. 191 of
2015 )
(2) (Repealed L.N. 191 of 2015 )
(3) Where, in any
workplace,
the number of persons (whether male persons or female persons, or both) does not
exceed 10, there must be provided not less than one watercloset
fitment and one lavatory basin.
(4) In every
workplace,
the watercloset fitments, urinals and lavatory basins for male persons and the
watercloset fitments and lavatory basins for female persons shall be provided in
separate rooms exclusively for the use of male persons and female persons
respectively.
(5)
For the purposes of this regulation—
(a)
the number of persons in a workplace is to be determined— (i) for an office—at the rate of 1 person for every 9 m 2 of the
usable floor area of the office; (ii) for an industrial undertaking that is a flatted factory—at the rate of
1 person for every 4.5 m 2 of the usable floor area of the
factory; (iii) for an industrial undertaking that is a warehouse, godown or storage
area—at the rate of 1 person for every 30 m 2 of the usable floor
area of the warehouse, godown or storage area, as the case may be;
(iv) for a shop that is neither within a shopping arcade nor within a
department store—at the rate of 1 person for every 15 m 2 of the
usable floor area of the shop; or (v) for a food room of a restaurant, where the number of persons in the
restaurant (determined in accordance with regulation 8(2)(a)) is more than
300—at the rate of 1 person for every 4.5 m 2 of the usable floor
area of the food room; ( L.N. 191 of
2015 )
(b) the number of persons
in
an industrial undertaking (other than a flatted factory, warehouse, godown or
storage area) is to be determined by the Commissioner for
Labour; and
(c)
the proportion of male persons to female persons in a workplace is— (i) for an industrial undertaking (other than a flatted factory, warehouse,
godown or storage area), determined by the Commissioner for Labour;
and (ii) for any other workplace, deemed to be 1:1. ( L.N. 191 of 2015 ) ( L.N. 191 of 2015 ) 6. Places of public entertainment
(1)
In every place of
public
entertainment— ( L.N. 191 of
2015 )
(a) the number of watercloset fitments and urinals provided for male persons
must be not less than the number specified in Table 8;
(b) the number of watercloset fitments provided for female persons must be not
less than the number specified in Table 9; and
(c)
the number of lavatory basins provided for— (i) male persons must be not less than the number specified in item 1 of
Table 10; and (ii) female persons must be not less than the number specified in item 2 of
Table 10.
Table 8
Number of
Watercloset Fitments and Urinals Provided for Male Persons
in Place of Public Entertainment
Column 1
Column 2
Column 3
Number of male
persons in place of
public
entertainment
Number of watercloset fitments
Number of urinals
1.
Not more than 400
1 for every 100 male persons or part of those persons
1 for every 50 male persons or part of those persons
2.
More than 400
4 plus 1 for every 250 male persons, or part of those persons,
over 400
1 for every 50 male persons or part of those persons
( L.N. 191 of 2015 )
Table 9
Number of
Watercloset Fitments Provided for Female Persons in Place of
Public Entertainment
Column 1
Column 2
Number of female
persons in place of
public
entertainment
Number of watercloset fitments
1.
Not more than 250
2 for every 50 female persons or part of
those persons
2.
More than 25
10 plus 1 for every 40 female persons, or
part of those persons, over 250
( L.N. 191 of
2015 )
Table 10
Number of
Lavatory Basins Provided in Place of Public
Entertainment
Column 1
Column 2
Persons in place of public entertainment
Number of lavatory basins
1.
Male persons
1 for every 100 male persons or part of
those persons
2.
Female persons
1 for every 100 female persons or part of
those persons
( L.N. 191 of
2015 )
(2) In every place of public
entertainment,
the watercloset fitments, urinals and lavatory basins for male persons and the
watercloset fitments and lavatory basins for female persons shall be provided in
separate rooms exclusively for the use of male persons and female persons
respectively.
(3)
For the purposes of this regulation—
(a)
the number of persons in a place of public entertainment is to be
determined— (i) for a museum or exhibition hall—at the rate of 1 person for every 2
m 2 of the usable floor area of the museum or exhibition hall,
as the case may be; (ii) for a venue for a dance party—at the rate of 1 person for every 0.75
m 2 of the usable floor area of the dancing area in the
venue; (iii) for an assembly area or auditorium without seating or with movable
seating—at the rate of 1 person for every 0.5 m 2 of the usable
floor area of the area intended for use by the spectators or visitors in the
assembly area or auditorium, as the case may be; or (iv) for an assembly area or auditorium with
non-movable
seating—at the rate of 1 person for every seat in the assembly area or
auditorium, as the case may be; and ( L.N. 191 of 2015 )
(b) the proportion of male persons to female persons
in
a place of public entertainment is deemed to be
1:1.5. ( L.N. 196 of
1996 ; L.N. 191 of 2015 ) 6A. Sports
stadia
(1)
In every sports stadium—
(a) the number of watercloset fitments and urinals provided for male persons
must be not less than the number specified in Table 11;
(b) the number of watercloset fitments provided for female persons must be not
less than the number specified in Table 12; and
(c)
the number of lavatory basins provided for— (i) male persons must be not less than the number specified in item 1 of
Table 13; and (ii) female persons must be not less than the number specified in item 2 of
Table
13.
Table 11
Number of
Watercloset Fitments and Urinals Provided for Male Persons
in Sports Stadium
Column 1
Column 2
Number of watercloset
fitments
Number of urinals
1.
1 for every 100 male persons or part of those persons
1 for every 100 male persons or part of those persons
Table 12
Number of
Watercloset Fitments Provided for Female Persons in Sports
Stadium
1.
1 for every 50 female persons or
part of those persons
Table 13
Number of
Lavatory Basins Provided in Sports Stadium
Column 1
Column 2
Persons in
sports stadium
Number of lavatory
basins
1.
Male persons
1 for every 100 male persons or part of
those persons
2.
Female persons
1 for every 100 female persons or part
of those persons
(2) In every sports stadium, the watercloset fitments, urinals and lavatory basins
for male persons and the watercloset fitments and lavatory basins for female persons
must be provided in separate rooms exclusively for the use of male persons and
female persons respectively.
(3)
For the purposes of this regulation—
(a)
the number of persons in a sports stadium is to be determined— (i) for a sports stadium without seating or with movable seating—at the
rate of 1 person for every 0.5 m 2 of the usable floor area of the
area intended for use by the spectators in the stadium; or (ii) for a sports stadium with non-movable seating—at the rate of 1 person
for every seat in the stadium; and
(b) the proportion of male persons to female persons in a sports stadium is
deemed to be 1:1. ( L.N. 191 of 2015 ) 7. Cinemas
(1)
In every cinema—
(a) the number of watercloset fitments and urinals provided for male persons
must be not less than the number specified in Table 14;
(b) the number of watercloset fitments provided for female persons must be not
less than the number specified in Table 15; and
(c)
the number of lavatory basins provided for— (i) male persons must be not less than the number specified in item 1 of
Table 16; and (ii) female persons must be not less than the number specified in item 2 of
Table
16.
Table 14
Number of
Watercloset Fitments and Urinals Provided for Male Persons
in Cinema
Column 1
Column 2
Column 3
Number of male persons in cinema
Number of watercloset fitments
Number of urinals
1.
Not more than 200
1
1 for every 100 male persons or part of
those person
2.
201–500
2
1 for every 100 male persons or part of
those persons
3.
501–1 000
3
1 for every 100 male persons or part of
those persons
4.
More than 1 000
3 plus 1 for every 500 male persons, or
part of those persons, over 1 000
1 for every 100 male persons or part of
those persons
Table 15
Number of
Watercloset Fitments Provided for Female Persons in
Cinema
Column 1
Column 2
Number of female
persons in cinema
Number of watercloset fitments
1.
Not more than 120
1 for every 40 female persons or part of
those persons
2.
121–250
3 plus 1 for every 65 female persons, or
part of those persons, over 120
3.
251–420
5 plus 1 for every 85 female persons, or
part of those persons, over 250
4.
More than 420
7 plus 1 for every 100 female persons, or
part of those persons, over 420
Table 16
Number of
Lavatory Basins Provided in Cinema
Column 1
Column 2
Persons in cinema
Number of lavatory basins
1.
Male persons
1 for every 100 male persons or part of
those persons
2.
Female persons
1 for every 100 female persons or part of
those persons
( L.N. 191 of
2015 )
(2) In every cinema, the watercloset fitments, urinals and lavatory basins for male
persons and the watercloset fitments and lavatory basins for female persons shall be
provided in separate rooms exclusively for the use of male persons and female
persons respectively.
(3)
For the purposes of this regulation—
(a) the number of persons in a cinema is to be determined at the rate of 1
person for every seat in the cinema; and ( L.N. 191 of 2015 )
(b) the proportion of male persons to female persons
in
a cinema is deemed to be 1:1.5.
( L.N. 191 of
2015 ) 7A. Shopping
arcades and department stores
(1)
In every shopping arcade or department store—
(a) the number of watercloset fitments and urinals provided for male persons
must be not less than the number specified in Table 17;
(b) the number of watercloset fitments provided for female persons must be not
less than the number specified in Table 18; and
(c)
the number of lavatory basins provided for— (i) male persons must be not less than the number specified in Part 1 of
Table 19; and (ii) female persons must be not less than the number specified in Part 2 of
Table 19.
Table 17
Number of
Watercloset Fitments and Urinals Provided for Male Persons
in Shopping Arcade or Department Store
Column 1
Column 2
Column 3
Number of male persons in shopping arcade or department store
Number of watercloset fitments
Number of urinals
1.
Not more than 500
1 for every 125 male persons or part of
those persons
1 for every 250 male persons or part of
those persons
2.
More than 500
4 plus 1 for every 250 male persons, or
part of those persons,
over 500
1 for every 250 male persons or part of
those persons
Table 18
Number of
Watercloset Fitments Provided for Female Persons in Shopping
Arcade or Department Store
Column 1
Column 2
Number of female persons
in shopping arcade
or
department store
Number of watercloset fitments
1.
Not more than 50
1 for every 25 female persons or part of
those persons
2.
51–125
3
3.
126–1 800
3 plus 1 for every 80 female persons, or
part of those persons, over 125
4.
More than 1 800
24 plus 1 for every 90 female persons, or
part of those persons, over 1 800
Table 19
Number of
Lavatory Basins Provided in Shopping Arcade or Department
Store
Part 1
Number of
Lavatory Basins Provided for Male Persons in Shopping Arcade
or Department Store
Column 1
Column 2
Number of male persons
in shopping arcade or
department
store
Number of lavatory basins
1.
Not more than 500
1 for every 125 male persons or part of
those persons
2.
More than 500
4 plus 1 for every 250 male persons, or
part of those persons, over 500
Part 2
Number of
Lavatory Basins Provided for Female Persons in Shopping
Arcade or Department Store
Column 1
Column 2
Number of female persons
in shopping arcade or
department
store
Number of lavatory basins
1.
Not more than 500
1 for every 125 female persons or part of
those persons
2.
More than 500
4 plus 1 for every 250 female persons, or
part of those persons, over 500
(2) In every shopping arcade or department store, the watercloset fitments, urinals
and lavatory basins for male persons and the watercloset fitments and lavatory
basins for female persons must be provided in separate rooms exclusively for the use
of male persons and female persons respectively.
(3)
For the purposes of this regulation—
(a)
the number of persons in a shopping arcade is to be determined— (i) for the basement, ground, first or second floor of the shopping
arcade—at the rate of 1 person for every 3 m 2 of the usable floor
area of the relevant floor of the shopping arcade; or (ii) for the third floor (or above) of the shopping arcade—at the rate of 1
person for every 4.5 m 2 of the usable floor area of the relevant
floor of the shopping arcade;
(b)
the number of persons in a department store is to be determined— (i) for the basement, ground, first or second floor of the department
store—at the rate of 1 person for every 3 m 2 of the usable floor
area of the relevant floor of the department store; or (ii) for the third floor (or above) of the department store—at the rate of 1
person for every 4.5 m 2 of the usable floor area of the relevant
floor of the department store; and
(c) the proportion of male persons to female persons in a shopping arcade or
department store is deemed to be 1:1.5.
(4)
In paragraph (3)(a) —
usable floor area ( 實用樓面面積 ), in
relation to a shopping arcade—
(a) means the aggregate of the areas of the floors in the shopping arcade;
but
(b)
does not include— (i) any staircase, lift landing or lavatory in the shopping arcade;
or (ii) any space occupied by machinery for a lift, or for the
air-conditioning or utility system or any other similar service,
provided for the shopping arcade.
( L.N. 191 of 2015 ) 7B. Religious
institutions
(1)
In every religious institution—
(a) the number of watercloset fitments and urinals provided for male persons
must be not less than the number specified in Table 20;
(b) the number of watercloset fitments provided for female persons must be not
less than the number specified in Table 21; and
(c)
the number of lavatory basins provided for— (i) male persons must be not less than the number specified in item 1 of
Table 22; and (ii) female persons must be not less than the number specified in item 2 of
Table 22. Table
20
Number of
Watercloset Fitments and Urinals Provided for Male Persons in
Religious Institution
Column 1
Column 2
Number
of watercloset
fitments
Number
of urinals
1.
1 for every 100 male persons or part of those
persons
1 for every 100 male persons or part of those
persons
Table
21
Number of
Watercloset Fitments Provided for Female Persons in Religious
Institution
1.
1 for every 50
female persons or part of those persons
Table
22
Number of
Lavatory Basins Provided in Religious Institution
Column 1
Column 2
Persons in religious
institution
Number of lavatory
basins
1.
Male persons
1 for every 100 male persons or part of
those persons
2.
Female persons
1 for every 100 female persons or part of
those persons
(2) In every religious institution, the watercloset fitments, urinals and lavatory
basins for male persons and the watercloset fitments and lavatory basins for female
persons must be provided in separate rooms exclusively for the use of male persons
and female persons respectively.
(3)
For the purposes of this regulation—
(a) the number of persons in a religious institution is to be determined at the
rate of 1 person for every 0.5 m 2 of the usable floor area of the
religious institution; and
(b) the proportion of male persons to female persons in a religious institution
is deemed to be 1:1.5. ( L.N. 191 of 2015 ) 7C. Funeral
parlours
(1)
In every funeral parlour—
(a) the number of watercloset fitments and urinals provided for male persons
must be not less than the number specified in Table 23;
(b) the number of watercloset fitments provided for female persons must be not
less than the number specified in Table 24; and
(c)
the number of lavatory basins provided for— (i) male persons must be not less than the number specified in item 1 of
Table 25; and (ii) female persons must be not less than the number specified in item 2 of
Table 25.
Table
23
Number of
Watercloset Fitments and Urinals Provided for Male Persons in
Funeral Parlour
Column 1
Column 2
Number of
watercloset
fitments
Number of urinals
1.
1 for every 150 male persons or part of those
persons
1 for every 150 male persons or part of those
persons
Table
24
Number of
Watercloset Fitments Provided for Female Persons in Funeral
Parlour
1.
1 for every 75
female persons or part of those persons
Table
25
Number of
Lavatory Basins Provided in Funeral Parlour
Column 1
Column 2
Persons in funeral
parlour
Number of lavatory
basins
1.
Male persons
1 for every 300 male persons or part of
those persons
2.
Female persons
1 for every 300 female persons or part of
those persons
(2) In every funeral parlour, the watercloset fitments, urinals and lavatory basins
for male persons and the watercloset fitments and lavatory basins for female persons
must be provided in separate rooms exclusively for the use of male persons and
female persons respectively.
(3)
For the purposes of this regulation—
(a) the number of persons in a funeral parlour is to be determined at the rate
of 1 person for every 0.5 m 2 of the usable floor area of the funeral
parlour; and
(b) the proportion of male persons to female persons in a funeral parlour is
deemed to be 1:1.5. ( L.N. 191 of 2015 ) 8. Restaurants
(1)
Subject to paragraph (1A), in every restaurant—
(a) the number of watercloset fitments and urinals provided for male persons
must be not less than the number specified in Table 26;
(b) the number of watercloset fitments provided for female persons must be not
less than the number specified in Table 27; and
(c)
the number of lavatory basins provided for— (i) male persons must be not less than the number specified in Part 1 of
Table 28; and (ii) female persons must be not less than the number specified in Part 2 of
Table 28. Table
26
Number of
Watercloset Fitments and Urinals Provided for Male Persons
in Restaurant
Column 1
Column 2
Column 3
Number
of
male persons
in restaurant
Number
of watercloset fitments
Number
of urinals
1.
Not more than 40
1
1
2.
41–80
1
2
3.
81–150
2
3
4.
151–200
2
4
5.
201–300
3
4 plus 1 for every 50 male persons, or
part of those persons, over 200
6.
301–400
4
6 plus 1 for every 50 male persons, or
part of those persons, over 300
7.
401–650
5
8 plus 1 for every 50 male persons, or
part of those persons, over 400
8.
More than 650
5 plus 1 for every 250 male persons, or
part of those persons, over 650
13 plus 1 for every 50 male persons, or
part of those persons, over 650
Table
27
Number of
Watercloset Fitments Provided for Female Persons in
Restaurant
Column 1
Column 2
Number of female
persons in restaurant
Number of watercloset
fitments
1.
Not more than 60
1
2.
61–120
2
3.
121–180
3
4.
181–200
4
5.
More than 200
4 plus 1 for every 100 female persons, or
part of those persons, over 200
Table
28
Number of
Lavatory Basins Provided in Restaurant
Part 1
Number of
Lavatory Basins Provided for Male Persons in
Restaurant
Column 1
Column 2
Number of male
persons in restaurant
Number of lavatory
basins
1.
Not more than 80
1
2.
81–120
2
3.
121–150
3
4.
More than 150
3 plus 1 for every 100 male persons, or
part of those persons, over 150
Part
2
Number of
Lavatory Basins Provided for Female Persons in
Restaurant
Column 1
Column 2
Number
of female
persons in restaurant
Number
of lavatory
basins
1.
Not more than 120
1
2.
121–180
2
3.
181–250
4
4.
More than 250
4 plus 1 for every 100 female persons, or
part of those persons, over 250
( L.N. 191 of
2015 )
(1A)
For a restaurant in which the number of persons (determined in accordance
with paragraph (2)(a) ) is less than 25, the requirements set out in
paragraph (1) are regarded as having been complied with if, in the
restaurant—
(a) 1 watercloset fitment and 1 lavatory basin are provided for both male
persons and female persons; and
(b) 1 urinal is provided for male persons. ( L.N. 191 of 2015 )
(1B)
Where, in a restaurant in which the number of persons (determined in accordance
with paragraph (2)(a) ) is less than 25, only—
(a) 1 watercloset fitment and 1 lavatory basin are provided for both male
persons and female persons; and
(b) 1 urinal is provided for male persons, the watercloset fitment and the urinal must be provided in separate rooms.
( L.N. 191 of
2015 )
(1C) In every restaurant (except a restaurant to which paragraph (1B) applies), the
watercloset fitments, urinals and lavatory basins for male persons and the
watercloset fitments and lavatory basins for female persons must be provided in
separate rooms exclusively for the use of male persons and female persons
respectively. ( L.N. 191 of
2015 )
(2)
For the purposes of this regulation—
(a) the number of persons in a restaurant is to be determined at the rate of 1
person for every 1.5 m 2 of the usable floor area of the restaurant
(excluding the food room of the restaurant); and ( L.N. 191 of 2015 )
(b) the proportion of male persons to female persons
in
a restaurant is deemed to be 1:1.5.
( L.N. 191 of
2015 ) 8A. (Repealed L.N. 242 of 1997 ) 9. Where soil fitments prohibited latrine fitments, etc. to be provided in lieu
thereof, etc.
(1)
Where, in any case, the installation of soil fitments is, under regulation
89 , prohibited—
(a) latrine fitments shall be provided in lieu of watercloset fitments, and the
number thereof shall be not less than the number of watercloset fitments
required by regulation 4 , 5 , 6 ,
6A ,
7 , 7A , 7B , 7C
or 8 , as the case may be; and
(b) bucket urinals shall be provided in lieu of urinals, and, likewise, the
number thereof shall be not less than the number of urinals required by
regulation 4 , 5 , 6 ,
6A ,
7 , 7A , 7B , 7C
or 8 , as the case may be.
(2) Where, by regulation 4 , 5 , 6 ,
6A ,
7 , 7A , 7B , 7C or
8 , the provision of watercloset fitments is required, trough
waterclosets may be provided and, for the purposes of those regulations, every metre
of trough watercloset shall be deemed to be the equivalent of one watercloset
fitment.
(3) Where, by regulation 4 , 5 , 6 ,
6A ,
7 , 7A , 7B , 7C or
8 , the provision of urinals is required, and trough urinals are
installed, every 0.5 m of trough urinals shall, for the purposes of those
regulations, be deemed to be the equivalent of one urinal. ( L.N. 294 of
1976 ; L.N. 191 of 2015 ) 10. (Repealed L.N. 191 of 2015 ) 10A. Supply of water
(1) Where under these regulations there is required to be provided in any building any watercloset fitment, trough watercloset, latrine fitment or urinal, there shall be a permanent connexion to such building of a supply of water which is satisfactory and sufficient in all respects for the purpose of flushing every such watercloset fitment, trough watercloset, latrine fitment or urinal and for all other purposes for which such supply is to be used.
(2) Where under these regulations there is required to be provided in any building any waste fitment or shower, there shall be a permanent connexion to such building of a supply of water which is satisfactory and sufficient in all respects for all the purposes for which every such waste fitment or shower is to be used and for all other purposes for which such supply is to be used.
(3)
The connexion of a supply of water for the purposes of paragraph (1) or (2) shall be—
(a) of a supply of water from the waterworks; or
(b) if the Building Authority gives his permission in writing, of a supply of water from a well within the site of the building; or
(c) if in all the circumstances of the case the Building Authority is satisfied that it is not reasonable that the connexion be of a supply of water from the waterworks or from a well within the site of the building, of a supply of water from such other source as the Building Authority may permit or direct.
(4) In determining whether a supply of water is satisfactory and sufficient under this regulation, regard shall be had to the nature, type and size of the building, the purpose for which it was constructed or is intended to be or is used and all the purposes for which the supply of water is or is likely to be used.
(5) Before the Building Authority gives his permission under paragraph (3)(b) for the connexion to a building of a supply of water from a well within the site of the building or before the Building Authority under paragraph (3)(c) permits or directs the connexion to a building of a supply of water from a source other than the waterworks or a well within the site of the building, there shall be produced to the Building Authority by the building owner a certificate from the water authority as to whether or not a supply of water from the waterworks is available for the purposes for which such connexion is made or to be made.
(6) The water authority shall issue the certificate required under paragraph (5) within 10 days of receiving an application in writing therefor.
(7)
For the purposes of this regulation—
(a) a supply of water shall be satisfactory if the yield of water from such well during a period from 1 December to 30 April next following, as ascertained and certified in accordance with this paragraph, would be sufficient in all respects for all the purposes for which the well is to be used; and
(b)
the yield of water from a well shall be ascertained by the authorized person by a recognized method— (i) during the first such period referred to in
subparagraph
(a), after the first consent to the commencement of the building works is
given by the Building Authority in respect of the building for which the
well is required or, if such first consent is given during such a period,
then during such period; or (ii) if the Building Authority so directs, during any such period as is
referred to in
subparagraph
(a) after the first consent to the commencement of the building works is
given by the Building Authority in respect of the building for which the
well is required; and
(c) the yield of water from the well ascertained in accordance with
subparagraph
(b) shall be certified by the authorized person. ( L.N. 439 of
1990 ) ( L.N. 62 of 1966 ) Part
III Plumbing Soil fitments and waste fitments 11. Disposal of soil All soil shall be properly conducted, by means of suitable soil pipes, to drains
provided for the carriage of foul water. ( G.N.A. 107 of 1959 ) 12. Waste pipes
(1)
Save as provided in paragraphs (2) and (3) waste pipes shall discharge in the open air—
(a) over or into a suitable channel within 1 m of a properly trapped gully; ( L.N. 294 of 1976 )
(b) into a gully, above the level of the water therein; or
(c) into a suitable hopper head.
(2)
Waste pipes from lavatory basins may discharge—
(a) into a suitable drainage channel immediately below the lavatory basins, if such drainage channel discharges into a trapped gully; or
(b) into a common waste pipe, if the common waste pipe discharges through a trap and has adequate means of access for cleaning.
(3) Subject to the provisions of regulation 25(3) , waste pipes may be connected to a soil pipe. 13. Materials for soil fitments Every soil fitment shall be constructed of glazed earthenware, enamelled fire clay or other approved material. 14. Construction of watercloset fitments
(1) Every watercloset fitment, other than a squatting type fitment, shall be of such shape, capacity and mode of construction as to retain a sufficient quantity of water and to receive normal deposits of excrement into such water without undue soiling of the sides of the fitment.
(2) Every watercloset fitment, other than a squatting type fitment, shall be provided with a hinged seat or a suitable seat rim or inset. ( L.N. 361 of 1980 ) 15. Construction of trough waterclosets The channel of a trough watercloset shall be not longer than 5 m and shall have an even fall towards the outlet trap of not less than 1 in 30. ( L.N. 294 of 1976 ) 16. Construction of urinal channels The channels of every stall and trough urinal shall have an even fall towards the outlet trap of not less than 1 in 120 and no part of any such channel shall be more than 6 m from the trap to which it discharges. ( L.N. 294 of 1976 ) 17. Flushing water supply
(1) A system of plumbing shall be provided for the supply of water for flushing purposes to every watercloset fitment, trough watercloset, urinal and slop sink.
(2) Every part of any such system of plumbing (including any storage tank for water solely for flushing purposes) shall be constructed of material that is suitable for use with salt water. ( L.N. 113 of 1964 ) 18. Flushing rim Every watercloset fitment, bidet, basin-type urinal and slop sink shall be provided with a suitable flushing rim for the effectual flushing of the fitting. 19. Flushing cisterns
(1) Save as provided in regulation 20 , every watercloset fitment, trough watercloset, urinal and slop sink shall be provided with a flushing cistern.
(2)
Such flushing cistern shall—
(a)
in the case of watercloset fitments and slop sinks— (i) discharge to the watercloset fitment of slop sink, on each occasion
such fitment is used, not less than 9
L
and not more than 14
L
of water; and (ii) be provided with a ball valve so arranged as to re-fill the cistern within 2 minutes;
(b)
in the case of trough waterclosets, be fitted with automatic discharging apparatus so arranged as to discharge— (i) at the highest point of the channel; (ii) at such intervals as may be necessary of ensure adequate cleaning of the closet, not less than 9
L
of water for every metre of the channel;
(c)
in the case of urinals, be fitted with automatic discharging apparatus so arranged as to discharge— (i) into every basin or stall or, in the case of a trough urinal, every
metre
thereof; (ii) at such intervals as may be necessary to ensure adequate cleaning of the urinal, not less than 4.5
L
of water. ( L.N. 294 of
1976 ; E.R. 3 of
2020 ) 20. Pressure valves Save in the case of trough waterclosets and urinals, pressure valves may, where there is a suitable head of water, be installed for flushing purposes without the provision of a flushing cistern. 21. Flushing pipes
The internal diameter of flushing pipes shall—
(a) in the case of watercloset fitments, trough waterclosets and slop sinks, be not less than 32 mm;
(b) in the case of urinals (other than trough urinals), be not less than 15 mm for each basin or stall; and
(c) in the case of trough urinals, be not less than 15 mm for every metre thereof. ( L.N. 294 of 1976 ) 22. Storage tanks for flushing water
(1) Storage tanks for water solely for flushing purposes shall be provided in every building in which watercloset fitments, trough waterclosets, urinals or slop sinks are installed.
(2)
Every such tank shall—
(a) at a position above the level of the highest fitment or on a suitable water tower;
(b) fitted with a suitable close fitting cover; and
(c) provided with adequate access to enable the tank to be entered and cleaned. 23. Overflow pipes
(1) Every flushing cistern and water storage tank shall be provided with an overflow pipe.
(2)
The overflow pipe from a water storage tank shall—
(a) have an internal diameter of one commercial size larger than the supply pipe to the cistern or tank; ( L.N. 361 of 1980 )
(b) dip down, inside the tank, so as to terminate in a position not more than 150 mm above the bottom of the tank; and ( L.N. 294 of 1976 )
(c) discharge in a conspicuous position. 24. Traps for soil fitments
(1) Every soil fitment shall be provided with a suitable trap with a water seal of not less than 50 mm.
(2)
The internal diameter of every such trap shall be not less than—
(a) 80 mm, in the case of a watercloset fitment, slop sink, or urinal with more than 3 basins or stalls or with a channel longer than 2 m;
(b) 50 mm, in the case of a urinal with more than one and not more than 3 basins or stalls or with a channel not longer than 2 m;
(c) 40 mm, in the case of a bidet or urinal with a single basin or stall; and
(d) 100 mm, in the case of a trough watercloset. ( L.N. 294 of 1976 ) 25. Traps for waste fitments
(1)
Every waste fitment shall be provided immediately under the fitment with a suitable trap:
Provided that a trap shall not be required—
(a)
where the waste pipe from such fitment— (i) does not exceed 1 m in length; and (ii) discharges over or into a suitable trapped gully;
(b) in respect of lavatory basins, where the waste pipes therefrom discharge in the manner provided by regulation 12(2) ;
(c) in respect of a range of shower baths, where the drainage channel provided therefor is provided, at its lowest point, with a trap.
(2)
Save as provided in paragraph (3), every trap provided for a waste fitment shall have—
(a) an internal diameter of not less than 32 mm; and
(b) a water seal of not less than 40 mm.
(3)
Where the waste pipe from a waste fitment is, under the provisions of regulation 12(3) , connected to a soil pipe, the trap provided for the waste fitment shall—
(a) have an internal diameter of not less than 32 mm;
(b) have a water seal of not less than 80 mm; and
(c)
be— (i) adequately ventilated; or (ii) constructed to prevent loss of water seal. ( L.N. 294 of 1976 ) Pipes and eaves gutters 26. Soil pipes
(1)
The internal diameter of every soil pipe from a watercloset fitment or slop sink
shall be not less than—
(a) 80 mm; or ( L.N. 294 of 1976 )
(b) the internal diameter of the outlet pipe of the trap of any fitment to
which the soil pipe is connected, whichever is the greater.
(2) The internal diameter of every soil pipe from a urinal or bidet shall be not
less than the internal diameter of the outlet pipe of the trap of any fitment to
which the soil pipe is connected.
(3) Every soil pipe shall be properly connected to a covered drain without the
intervention of any trap. 27. Waste pipes
(1)
Waste pipes to which the waste from one waste fitment is
discharged
shall have an internal diameter of not less than—
( E.R. 3 of
2020 )
(a) 32 mm; or ( L.N. 294 of 1976 )
(b) the internal diameter of the outlet of the trap to which the waste pipe is
connected, whichever is the greater.
(2) Waste pipes to which the waste from more than one fitment is discharged shall be of adequate diameter to convey all such waste.
(3) Every waste pipe shall terminate at its lower end not more than 150 mm above the channel or trapped gully over or into which it discharges. ( L.N. 294 of 1976 ) 28. Bends in soil and waste pipes
(1) Soil pipes and waste pipes shall not have bends therein, except where unavoidable.
(2)
Whenever a bend is unavoidable—
(a)
the bend shall— (i) have an obtuse angle; (ii) have the largest practicable radius of curvature; and (iii) not change in any way the cross section of the pipe;
and
(b) a cleaning eye or other suitable means of access shall be provided at or near the bend. 29. Access to soil and waste pipes
(1) Sufficient access shall be provided, by means of cleaning eyes or other approved method, to enable soil pipes and waste pipes to be cleared of any obstruction.
(2) Such access points shall be so sited as to allow clearance for the easy entry of cleaning rods. 30. Anti-syphonage pipes
(1)
Where—
(a) more than one trap of a watercloset fitment, urinal, slop sink or waste fitment is connected with one soil pipe; or
(b) more than one trap of a waste fitment is connected with one waste pipe, the traps shall be ventilated by means of anti-syphonage pipes: Provided that if, in the case of waste fitments, the traps to such fitments are constructed to prevent loss of water seal, it shall not be necessary to provide an anti-syphonage pipe, unless the Building Authority so requires.
(2)
Every anti-syphonage pipe shall be connected with—
(a) the trap, if the connexion with the anti-syphonage pipe is an integral part of the trap; or
(b)
the branch soil pipe or branch waste pipe— (i) on the side of the water seal nearest the main soil pipe or waste pipe; and (ii) at a point not more than 300 mm from the trap outlet. ( L.N. 294 of 1976 )
(3)
The internal diameter of every anti-syphonage pipe shall—
(a) if the diameter of the soil pipe or waste pipe to which it is connected is 80 mm or more, be not less than 50 mm;
(b)
if the diameter of such soil pipe or waste pipe is less than 80 mm, be not less than— (i) two-thirds of the internal diameter of such soil pipe or waste pipe; or (ii) 32 mm, whichever is the greater. ( L.N. 294 of 1976 )
(4)
(a) The main anti-syphonage pipe may be connected to a soil pipe which, under
regulation 31(3) , is acting as a ventilating
pipe.
(b) Every
such connexion shall be made at a point above the flood level of the highest
fitment connected to the soil pipe.
( E.R. 3 of
2020 ) 31. Ventilating pipes
(1) Every ventilating pipe for any drain or sewer shall be carried up to a height not less than 1 m above the roof of the building to which it is fixed or, where such building has a pitched roof, above the eaves of such building. ( L.N. 294 of 1976 )
(2) No ventilating pipe shall be so fixed as to permit the escape of foul air from any drain, sewer, soil pipe or waste pipe into any building.
(3) Soil pipes or waste pipes may be carried up to a suitable height above the building to which they are fixed to act as ventilating pipes for any drain or sewer.
(4) The internal diameter of every ventilating pipe and of every soil pipe or waste pipe which, under paragraph (3), is acting as a ventilating pipe, shall be not less than 80 mm. ( L.N. 294 of 1976 )
(5) The open end of every ventilating pipe shall be provided with a suitable grating having apertures of an aggregate area not less than the sectional area of the pipe.
(6) Ventilating pipes shall not be used for the carriage of surface water. 32. Rain water pipes
(1)
(a)
Every rain water pipe which discharges to a drain which is connected to a public sewer provided for the carriage of surface water shall— (i) in the case of a rain water pipe situated outside a building, discharge either not more than 150 mm above the level of the ground over a suitably trapped gully or into a trapped gully below the level of the grating but above the level of the water in the trap; and (ii) in the case of a rain water pipe situated inside a building (other than a rain water pipe used solely for the conveyance of rain water from a roof), be properly trapped with an efficient trap which shall be so formed and fixed as to maintain a water seal of not less than 75 mm. ( L.N. 62 of 1966 ; L.N. 361 of 1980 )
(b) Every rain water pipe which discharges to a channel shall discharge at a height not more than 150 mm above the level of the top of the channel.
(c) Every rain water pipe which discharges, through a cast iron conductor, to the side channel in a street shall be provided, at the foot thereof, with a shoe so as to ensure that any surface water discharged from the pipe will discharge directly into the conductor.
(2) The number and size of rain water pipes provided for any building shall be
calculated at the rate of 700
mm 2
of pipe to every 10
m 2
of horizontal roofed-over surface.
(3) Save as provided in regulation 33 , the diameter of every rain water pipe shall be not less than 65 mm.
(4) Rain water pipes shall not be connected with any soil pipe, waste pipe or ventilating pipe.
(5) Where a rain water pipe discharges, across any footpath, to the side channel of a street, it shall discharge through a cast iron conductor. ( L.N. 294 of 1976 ) 33. Rain water pipes for verandahs or balconies
(1) Any rain water pipe provided for the carriage of surface water from a verandah or balcony shall, where there is, at a suitable position, a rain water pipe provided for the carriage of surface water from the roof of the building, be connected to such pipe.
(2) Where a rain water pipe provided for the carriage of surface water from a verandah or balcony discharges to the side channel in a street or is, in accordance with paragraph (1), connected to a rain water pipe which so discharges, the internal diameter of the rain water pipe from the verandah or balcony shall be not more than 40 mm. ( L.N. 294 of 1976 ) 34. Materials for pipes
(1)
Every soil pipe, waste pipe, anti-syphonage pipe, ventilating pipe, overflow pipe and every pipe connected with any drain provided for the carriage of foul water shall be—
(a) circular in shape; and
(b) constructed of cast iron, steel, copper or other approved material.
(2) Every rain water pipe shall be constructed of cast iron, copper or other approved material. ( L.N. 295 of 1986 )
(3) All such materials shall be sound and free from defects. 35. Connexions of pipes, etc. Every connexion of a soil pipe, waste pipe, anti-syphonage pipe, ventilating pipe, rain water pipe or overflow pipe with any other pipe, or with a trap, gutter or other fitting, as the case may be, shall be made in a manner suitable to the nature of the materials of which such pipe and such other pipe or trap, gutter or other fitting are constructed, and so as to be watertight. ( G.N.A. 107 of 1959 ) 36. Fixing of pipes
(1) Every soil pipe, waste pipe and rain water pipe shall be securely fixed to the wall of the building for which it is provided.
(2) Any hole which is made in any floor or wall in order to admit any such pipe shall be properly filled in and sealed round the pipe. 37. Pipes in ducts Where a soil pipe, waste pipe, anti-syphonage pipe, ventilating pipe, or rain water pipe is fixed in a duct within a building, access panels shall be provided of such size and so situated that adequate access is available to all pipe connexions within the duct. 38. Eaves gutters
(1)
Eaves gutters shall be—
(a) made of cast iron or other approved material;
(b) fixed at a gradient not less than 1 in 100; and
(c) properly connected to rain water pipes.
(2) The size of eaves gutters shall be calculated at the rate of 700 mm 2 of cross sectional area of gutter to every 7 m 2 of horizontal roofed-over surface. ( L.N. 294 of 1976 ) 38A. British Standard Specification and other national standards The Building Authority may permit, in writing and subject to such conditions as he
may endorse thereon, the use of materials or the carrying out of any works that are
subject to this Part in accordance with a relevant British Standard Specification,
British Standard Code of Practice or other national standard accepted by the Building
Authority and that prescribes the quality of material or standards of
workmanship. ( L.N. 361 of 1980 ) Part
IV Drainage
Works 39. Drainage of buildings Every building shall be provided with such pipes, drains and channels as are necessary for the disposal of all foul water and surface water from the building. 40. Disposal of foul water
(1) Drains and private sewers, provided for the carriage of foul water, shall, where there is a public sewer provided for the carriage of foul water at a suitable level and position within 30 m of the boundary of the lot on which the building, for which such drains or private sewers are provided, is erected, be connected to such public sewer. ( L.N. 294 of 1976 )
(2) Where there is no such public sewer, the Building Authority may, by order in writing, require the owner of any building to provide a septic tank, a cesspool or other approved facility. ( L.N. 361 of 1980 ) 41. Disposal of surface water
(1) Save as provided in paragraph (2), all surface water from a building shall, if there is a public sewer, provided for the carriage of surface water, at a suitable level and position within 30 m of the building, be conducted, by means of rain water pipes and drains provided for the carriage of surface water, to such public sewer or, where there is no such public sewer, shall be conducted, to the satisfaction of the Building Authority, to a public channel provided for the carriage of surface water or to the side channel in a street. ( L.N. 294 of 1976 )
(2) Where there is no such public sewer and no public channel or side channel in a street, such surface water shall be conducted, to the satisfaction of the Building Authority, to a stream course or nullah. 42. Pipes carrying surface water not to discharge across surface of footpath No pipe provided for the carriage of surface water from a building shall discharge across the surface of any footpath in a street. 43. Disposal of sub-soil water Drains provided for the carriage of sub-soil water may be connected to a private or public sewer provided for the carriage of surface water or to a drain provided therefor. 44. Materials for drains, etc.
(1) Covered drains (except covered drains provided for the carriage of sub-soil water) and covered sewers shall be made with good sound pipes of glazed earthenware, stone ware, concrete, cast iron or other approved material.
(2) Drains and sewers above the ground shall be laid with cast iron pipes or other approved materials. ( L.N. 361 of 1980 )
(3)
All pipes used in the construction of any drain or sewer shall—
(a) be of true bore;
(b) have smooth internal surfaces; and
(c) be impervious.
(4) Cast iron sewage pipes shall be protected against rust and corrosion by a suitable asphaltic coating.
(5)
Earthenware, stone ware and concrete pipes shall—
(a) in the case of pipes with a diameter not exceeding 150 mm, have a thickness equal to not less than one-ninth of the diameter of the pipe; and
(b) in the case of pipes with a diameter exceeding 150 mm, have a thickness equal to not less than one-twelfth of the diameter of the pipe. ( L.N. 294 of 1976 ) 45. Sub-soil water dr
The text continues in the official source.
