    HK Cap. 123F

    HK Cap. 123F — Building (Planning) Regulations

    Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.

    Analyze this law with AI
    Building (Planning) Regulations ( Cap. 123, section 38 ) [1 June 1956] (Format changes— E.R. 1 of 2012 ) Part I General (Format changes— E.R. 1 of 2012 ) 1. Citation These regulations may be cited as the Building (Planning) Regulations . 2. Interpretation (1) In these regulations, unless the context otherwise requires, words and expression have the meaning attributed to them by the Buildings Ordinance ( Cap. 123 ), and— access facilities ( 接達設施 ) means facilities for access of telecommunications and broadcasting services, including a room, duct or riser used for the installation of cables, wires and other ancillary equipment for telecommunications and broadcasting purposes; ( 39 of 2000 s. 7 ) balcony ( 露台 ) means any structure projecting from any wall of any building to carry a floor or roof load either cantilevered or supported by brackets; broadcasting ( 廣播 ) means transmission of sound or television programmes by satellite or terrestrial telecommunications intended for general reception; ( 39 of 2000 s. 7 ) canopy ( 簷篷 ) means any structure which projects more than 500 mm from any wall of any building and at a height of not more than 7.5 m above the level of the ground to provide protection from rain or sun, not carrying any floor load, either cantilevered or supported by brackets; ( G.N.A. 83 of 1959 ; L.N. 294 of 1976 ; L.N. 79 of 1992 ) cinema ( 電影院 ) means any building or part of a building which is designed for, and contains facilities (including a projection room) and projection or other apparatus or equipment for use in connection with or otherwise for the purposes of cinematographic displays; ( L.N. 194 of 1996 ) commercial building ( 商業建築物 ) has the same meaning assigned to it in section 2 of the Building (Energy Efficiency) Regulation ( Cap. 123 sub. leg. M ); ( 39 of 2000 s. 7 ) detached building ( 獨立建築物 ) means any building which is not connected to any other building and has a clear and unobstructed open space— (a) extending the entire depth of the building of not less than 2.3 m measured at right angles to the external surface of the building; ( L.N. 294 of 1976 ) (b) in the rear of the building of a depth of 2.3 m measured at right angles to the external surface of the building and extending for the full width of the site; ( L.N. 294 of 1976 ) disability ( 殘疾 ), in relation to a person, means impairment in vision, hearing or locomotion because of injury, disease or congenital deformity; ( L.N. 239 of 1997 ) drying rack ( 晾衣架 ) means a structure for hanging clothes or garments for drying; ( 20 of 2008 s. 45 ) external wall ( 外牆 ) means the whole, or any part, of an outer wall of a building not being a party wall, even though adjoining a wall of another building; ( 16 of 2011 s. 41 ) factory ( 工廠 ) means any building or place in which any machinery, other than machinery worked entirely by hand, is used in aid of any industrial undertaking carried on in such building or place; floor ( 樓面 ) means any structure forming the base of any storey and every joist, board, timber, brick, concrete or other substance connected with and forming part of such structure; hotel building ( 旅館建築物 ) means a building which is constructed or intended to be used as a hotel; ( 39 of 2000 s. 7 ) industrial building ( 工業建築物 ) has the same meaning assigned to it in regulation 2 of the Building (Refuse Storage and Material Recovery Chambers and Refuse Chutes) Regulations ( Cap. 123 sub. leg. H ); ( 39 of 2000 s. 7 ) latrine ( 廁所 ) means a privy, commode or earth closet but does not include a water closet or a water flushed urinal; open air ( 露天地方 ) means a space which— (a) is vertically uncovered and unobstructed; (b) is not less, in any horizontal dimension, than 1.5 m; and (c) where such space is enclosed on 4 sides, has a horizontal area of not less than 1 m 2 for every 6 m of the mean height of the walls enclosing the space; ( G.N.A. 83 of 1959 ; L.N. 294 of 1976 ) Ordinance ( 本條例 ) means the Buildings Ordinance ( Cap. 123 ); permitted plot ratio ( 准許地積比率 ) means the maximum plot ratio permitted under paragraph (1) or (2), as the case may be, of regulation 21 ; ( G.N.A. 97 of 1962 ) prescribed ( 訂明 ) means prescribed by or under the Ordinance; ( G.N.A. 83 of 1959 ) residential building ( 住宅建築物 ) has the same meaning assigned to it in regulation 3 of the Building (Standards of Sanitary Fitments, Plumbing, Drainage Works and Latrines) Regulations ( Cap. 123 sub. leg. I ); ( 39 of 2000 s. 7 ) residential unit ( 住宅單位 )— (a) means a separate unit in a building that would have been a residential building had the unit been a whole building; but (b) does not include a unit that is under a specified public housing scheme; ( L.N. 52 of 2026 ) road ( 道路 ) means a street not including any footpath; room ( 房間 ) means any portion of a building which has been subdivided by the erection of partition walls from floor to ceiling; semi-detached building ( 半獨立建築物 ) means any one of a pair of buildings connected to each other by a party wall and has a clear and unobstructed open space— (a) extending the entire depth of the building of not less than 2.3 m measured at right angles to the external surface of the building; ( L.N. 294 of 1976 ) (b) in the rear of the building of a depth of 2.3 m measured at right angles to the external surface of the building and extending for the full width of the site; ( L.N. 294 of 1976 ) single-household building ( 單一住户建築物 )— (a) means a building that is intended to be used for habitation by a single household; but (b) does not include a building that is intended to be used as a hotel, guest-house, boarding-house, hostel, dormitory or similar accommodation; ( L.N. 52 of 2026 ) site coverage ( 上蓋面積 ) means the area of the site that is covered by the building that is erected thereon and, when used in relation to a part of a composite building, means the area of the site on which the building is erected that is covered by that part of the building; ( G.N.A. 97 of 1962 ) specified building ( 指明建築物 ) means any building that is not any of the following— (a) a single-household building; (b) a building the whole of which is under a specified public housing scheme; (c) a temporary building or contractor’s shed referred to in Part VII; ( L.N. 52 of 2026 ) specified public housing scheme ( 指明公營房屋計劃 ) means— (a) the public housing scheme known as Transitional Housing; or (b) the public housing scheme known as Light Public Housing; ( L.N. 52 of 2026 ) storey ( 樓層 ) means the space between the upper surface of every floor and the upper surface of the floor next above it where such a floor exists and in the case of a top storey the space between the upper surface of that floor and the mean height of the ceiling or roof; street ( 街道 ) includes any footpath and private and public street; telecommunications ( 電訊 ) has the meaning assigned to it in section 2 of the Telecommunications Ordinance ( Cap. 106 ); ( 39 of 2000 s. 7 ) usable floor space ( 實用樓面空間 ) means any floor space other than staircases, staircase halls, lift landings, the space used in providing water-closet fitments, urinals and lavatory basins and the space occupied by machinery for any lift, air-conditioning system or similar service; ( G.N.A. 97 of 1962 ) verandah ( 外廊 ) means any structure projecting from any wall of any building and supported by piers or columns. ( L.N. 194 of 1996 ; L.N. 239 of 1997 ; L.N. 110 of 2005 ) (2) (Repealed L.N. 110 of 2005 ) ( 73 of 1983 s. 3 ) 3. Protection of balconies and verandahs (1)-(2) (Repealed L.N. 439 of 1990 ) (3) Every balcony projected from an upper storey of a building shall have a clear height, upwards from the floor of such balcony, of not less than the clear height of the storey from which it projects. ( L.N. 406 of 1987 ) 3A. Protection of openings (1) Every opening placed on an external wall above the ground floor of any building shall be protected by a barrier which shall be not less than 1 100 mm high and the lowermost 150 mm of such barrier shall be built solid. (2) A barrier provided under paragraph (1) shall be so designed as to minimize the risk of persons or objects falling, rolling, sliding or slipping through gaps in the barrier, or persons climbing over the barrier. ( L.N. 406 of 1987 ) 4. Buildings not to obstruct, endanger or cause nuisances No building or fixture thereon shall be so constructed that it— (a) (i) obstructs; or (ii) endangers the users of any adjacent footpath or street; or (b) creates any nuisance; or (c) permits the escape into or over any adjacent footpath or street at a height of less than 2.5 m of any noxious gases or exhaust from any ventilating system. ( L.N. 294 of 1976 ) 5. Access to buildings and provision of access lanes, etc., on site of new building (1) Every building shall be provided with means of obtaining access thereto from a street. (2) The Building Authority may require the provision of an access lane or access road within the site of any new building. ( G.N.A. 83 of 1959 ) 6. Building Authority to determine width of road or street Where for the purposes of these regulations it is necessary to determine the width of any road or street, the same shall be determined by the Building Authority. Part II Projections (Format changes— E.R. 5 of 2020 ) 7. Eaves, cornices, mouldings, etc. (1) An architectural projection (including eaves, cornice and moulding) that projects over a street— (a) must not project over the street more than 500 mm; and (b) must not project at a height of less than 2.5 m above the ground level. (2) A pipe or gutter (including the appurtenances of the pipe or gutter) that projects over a street— (a) must not project over the street more than 300 mm; and (b) must not project at a height of less than 2.5 m above the ground level. (3) A specified structure that projects over a street— (a) must not project over the street more than 750 mm; and (b) must not project at a height of less than 2.5 m above the ground level. (4) A retractable awning that projects over a street— (a) must not project over the street more than 500 mm (when retracted) or more than 2.5 m (when fully extended); (b) must not project at a height of less than 2.5 m above the ground level; (c) if it projects over a street that has a carriage-way—must have a horizontal clearance of not less than 600 mm from the pavement kerb line; and (d) if it projects over a street that consists only of a footpath—must have a horizontal clearance of not less than 1.5 m from the centre line of the footpath. (5) A metal ventilation duct (including the associated supporting frame) that projects over a street— (a) must not project over the street more than 750 mm; (b) must not project at a height of less than 2.5 m above the ground level; and (c) if the duct or any part of it is located on, or hung underneath the soffit of, a balcony, verandah or canopy of a building—must not project beyond the edge of the balcony, verandah or canopy. (6) In this regulation— pipe ( 喉管 ) includes a water pipe and a drain pipe; specified structure ( 指明構築物 ) means— (a) a drying rack; or (b) a supporting frame for an air-conditioning unit, light fitting, or antenna or transceiver for public telecommunications services. ( L.N. 61 of 2020 ) 8. (Repealed L.N. 79 of 1992 ) 9. (Repealed L.N. 79 of 1992 ) 10. Balconies and canopies over streets (1) Every canopy erected within 600 mm of the outer edge of a footpath, or projecting over a road, shall have a clear space of not less than 5.5 m beneath every part thereof. (2) Every canopy erected over a footpath shall have a clear space of not less than 3.3 m beneath every part thereof. (3) Every canopy shall be provided with adequate surface water drainage. ( L.N. 79 of 1992 ) (4) The maximum projection of any canopy (including cornices, mouldings or other features) erected over any street shall be— (a) one-tenth of the width of the street; or (b) 3 m, whichever is the less: Provided that no portion of any such canopy shall be within 4.5 m, measured horizontally, of a line drawn vertically from a point in the centre line of the street nearest to such portion of the canopy. ( L.N. 33 of 1966 ) (5) (Repealed L.N. 79 of 1992 ) ( L.N. 54 of 1969 ; L.N. 294 of 1976 ; L.N. 79 of 1992 ) 11. (Repealed L.N. 79 of 1992 ) 12. No doorways on to canopy No doorway giving direct access to the top of any canopy shall be made in the external wall of any building. 13. Use of verandahs or balconies Where any verandah or balcony has been built over or upon any street no such verandah or balcony shall be used or adapted to be used as a factory, workshop, storeroom, kitchen, lavatory, bathroom, water-closet, urinal or latrine. ( L.N. 79 of 1992 ) 14. (Repealed L.N. 57 of 1965 ) 15. Doors, etc. not to open over streets (1) Subject to paragraph (2), no door, gate, window or shutter opening on or over any street shall be so hung or placed as to project over such street at a height of less than 2.5 m above the ground. (2) Emergency exit doors, electrical transformer room doors, plant room doors, refuse storage chamber doors and doors leading to similar types of utility rooms or chambers may open outwards over such a street if such doors when fully opened do not cause an obstruction to any person or vehicle using the street. ( L.N. 79 of 1992 ) Part III Heights, Site Coverage, Plot Ratio, Open Spaces and Lanes ( L.N. 54 of 1969 ) (Format changes— E.R. 5 of 2020 ) 16. (Repealed L.N. 406 of 1987 ) 17. (Repealed L.N. 54 of 1969 ) 18. (Repealed L.N. 54 of 1969 ) 18A. Site classification (1) In this Part and the First and Second Schedules — class A site (甲類地盤) means a site, not being a class B site or class C site, that abuts on one specified street not less than 4.5 m wide or on more than one such street; class B site (乙類地盤) means, subject to paragraph (2), a corner site that abuts on 2 specified streets neither of which is less than 4.5 m wide; class C site (丙類地盤) means, subject to paragraph (2), a corner site that abuts on 3 specified streets none of which is less than 4.5 m wide. (2) For the purposes of paragraph (1)— (a) a corner site shall not be regarded as abutting on 2 specified streets unless at least 40 per cent of the boundary of the site abuts on the streets; and (b) a corner site shall not be regarded as abutting on 3 specified streets unless at least 60 per cent of the boundary of the site abuts on the streets. (3) A street is to be regarded as a specified street— (a) if there exists, with respect to the street, any of the following circumstances— (i) the street is vested in the Government and is maintained by the Highways Department; (ii) the street is a private street on land held under the same Government lease as the site and under the terms of the lease the lessee has to surrender (when required to do so) the land on which the street is situated to the Government; (iii) the street is a street required to be constructed on unleased Government land by the lessee of the Government lease under which the site is held pursuant to the terms of that lease; (iv) the street is on land over which the owner of the site is expressly granted, by or by virtue of an instrument, a right of way exercisable at all times; (v) the street is on land held under a Government lease by the owner of the site; or (b) if— (i) one or more of the circumstances mentioned in subparagraph (a)(i) , (ii), (iii), (iv) and (v) exist with respect to different parts of the street; and (ii) those parts together constitute the street. ( L.N. 110 of 2005 ) 19. General provisions concerning site coverage and plot ratio (1) The maximum site coverage permitted in respect of a building or buildings on a class A site, class B site or class C site shall be determined in accordance with regulation 20 . (2) The maximum plot ratio permitted in respect of a building or buildings on a class A site, class B site or class C site shall be determined in accordance with regulation 21 . (3) The height of a building or buildings on a site that is not a class A site, class B site or class C site, and the maximum site coverage and maximum plot ratio permitted in respect of such a building or buildings, shall be determined by the Building Authority. ( L.N. 110 of 2005 ) 19A. (Repealed L.N. 406 of 1987 ) 20. Permitted site coverage (1) Subject to regulation 22 and depending on the height of the building— ( L.N. 78 of 1970 ; L.N. 406 of 1987 ) (a) the site coverage for a domestic building, or for the domestic part of a composite building, on a class A site shall not exceed that percentage of the area of the site specified in the second column of the First Schedule ; (b) the site coverage for a domestic building, or for the domestic part of a composite building, on a class B site shall not exceed that percentage of the area of the site specified in the third column of the First Schedule ; and (c) the site coverage for a domestic building, or for the domestic part of a composite building, on a class C site shall not exceed that percentage of the area of the site specified in the fourth column of the First Schedule . (2) Subject to regulation 22 and paragraph (3) and depending on the height of the building— ( L.N. 78 of 1970 ; L.N. 406 of 1987 ) (a) the site coverage for a non-domestic building, or for the non-domestic part of a composite building, on a class A site shall not exceed that percentage of the area of the site specified in the eighth column of the First Schedule ; (b) the site coverage for a non-domestic building, or for the non-domestic part of a composite building, on a class B site shall not exceed that percentage of the area of the site specified in the ninth column of the First Schedule ; and (c) the site coverage for a non-domestic building, or for the non-domestic part of a composite building, on a class C site shall not exceed that percentage of the area of the site specified in the tenth column of the First Schedule . (3) Subject to the provisions of paragraph (4), the site coverage for a non-domestic building, or for the non-domestic part of a composite building, on a class A, B or C site may, whatever the height of the building, exceed the permitted percentage site coverage to a height not exceeding 15 m above ground level. ( L.N. 294 of 1976 ) (4) For the avoidance of doubt, it is hereby declared that, where pursuant to paragraph (3) the permitted percentage site coverage is exceeded— (a) above the level to which the permitted percentage site coverage is exceeded, the site coverage for the building or any part thereof shall not, subject to regulation 22 , exceed the site coverage permitted under paragraph (1) or (2), as the case may be; and ( L.N. 406 of 1987 ) (b) the plot ratio for the whole building shall not, subject to regulation 22 , exceed the permitted plot ratio. ( L.N. 406 of 1987 ) (5) In this regulation, the expression permitted percentage site coverage ( 准許上蓋面積百分率 ) means the maximum site coverage permitted under paragraph (2). ( G.N.A. 97 of 1962 ) 21. Permitted plot ratio (1) Subject to regulation 22 and depending on the height of the building— ( L.N. 78 of 1970 ; L.N. 406 of 1987 ) (a) the plot ratio for a domestic building on a class A site shall not exceed the plot ratio specified in the fifth column of the First Schedule ; (b) the plot ratio for a domestic building on a class B site shall not exceed the plot ratio specified in the sixth column of the First Schedule ; (c) the plot ratio for a domestic building on a class C site shall not exceed the plot ratio specified in the seventh column of the First Schedule ; (d) the plot ratio for a non-domestic building on a class A site shall not exceed the plot ratio specified in the eleventh column of the First Schedule ; (e) the plot ratio for a non-domestic building on a class B site shall not exceed the plot ratio specified in the twelfth column of the First Schedule ; and (f) the plot ratio for a non-domestic building on a class C site shall not exceed the plot ratio specified in the thirteenth column of the First Schedule . (2) Subject to regulation 22 , the plot ratio for the domestic part of a composite building shall not exceed the product of the difference between the permitted plot ratio for the building if it were a non-domestic building and the actual plot ratio of the non-domestic part of the building and the permitted plot ratio for the building if it were a domestic building divided by the permitted plot ratio for the building if it were a non-domestic building. ( L.N. 78 of 1970 ; L.N. 406 of 1987 ) (3) For the purposes of this regulation and of regulations 19 , 20 and 22 , the plot ratio of a building shall be obtained by dividing the gross floor area of the building by the area of the site on which the building is erected. ( G.N.A. 97 of 1962 ) 22. Permitted site coverage and plot ratio may be exceeded in certain cases (1) Where, between ground level and a height of not less than 5.5 m or, where the Building Authority is satisfied that there will be no obstruction to vehicular traffic using the street, 3.3 m above ground level, a building on a class A, B or C site is set back from a boundary of the lot on which it is erected, being a boundary that abuts on a street, and, with the consent of the Government, the part of the lot that is thereby not built upon is dedicated to the public for the purposes of passage— ( L.N. 406 of 1987 ; L.N. 57 of 1988 ) (a) the site coverage for the building or for any one part of the building may exceed the permitted percentage site coverage, so, however, that the site coverage therefor does not exceed that percentage of the area of the site equal to the sum of the permitted percentage site coverage for the building or for that part of the building, as the case may be, and the figure obtained by dividing the product of 1 500 and the area of the lot so dedicated to the public by the product of the area of the site and the height of the building; and (b) the plot ratio for the building or, if the building is a composite building, for the domestic part of the building may exceed the permitted plot ratio, so, however, that the plot ratio therefor is not greater than the permitted plot ratio for the building or for that part of the building, as the case may be, by more than 20 per centum or does not exceed the sum of the permitted plot ratio for the building or for that part of the building, as the case may be, and the figure obtained by dividing the product of 5 and the area of the lot so dedicated to the public by the area of the site on which the building is erected, whichever is the less. ( L.N. 294 of 1976 ) (2) Where part of a lot, being a part that abuts on a street, is acquired by the Government, either by agreement or by resumption under the Lands Resumption Ordinance ( Cap. 124 ), for the purpose of street widening, the Building Authority may permit— (a) the site coverage for a building erected on that lot, being a class A, B or C site, or for any one part of the building to exceed the permitted percentage site coverage, so, however, that the site coverage therefor does not exceed that percentage of the area of the site equal to the sum of the permitted percentage site coverage for the building or for that part of the building, as the case may be, and the figure obtained by dividing the product of 1500 and the area of the part of the lot so acquired by the Government by the product of the area of the site and the height of the building; and ( L.N. 294 of 1976 ) (b) the permitted plot ratio for the building or, if the building is a composite building, for the domestic part of the building to exceed the permitted plot ratio, so, however, that the plot ratio therefor is not greater than the permitted plot ratio for the building or for that part of the building, as the case may be, by more than 20 per centum or does not exceed the sum of the permitted plot ratio for the building or for that part of the building, as the case may be, and the figure obtained by dividing the product of 5 and the area of the part of the lot so acquired by the Government by the area of the site on which the building is erected, whichever is the less. ( 29 of 1998 s. 27 ) (3) For the avoidance of doubt, it is hereby declared that— (a) where under paragraph (1) or (2) the permitted percentage site coverage is exceeded in relation to a part of a building, the site coverage for any other part of the building shall not exceed the permitted percentage site coverage; (b) nothing in this regulation shall be taken or construed as derogating from the provisions of regulation 25 as to the amount of open space to be provided about a domestic building. (4) In this regulation, the expression permitted percentage site coverage ( 准許上蓋面積百分率 ) means the maximum site coverage permitted under paragraph (1) or (2), as the case may be, of regulation 20 . ( G.N.A. 97 of 1962 ) 23. Provisions supplementary to regulations 19 , 20 , 21 and 22 (1) For the purposes of regulations 20 , 21 and 22 , the height of a building shall be measured from the mean level of the street or streets on which it fronts or abuts being a specified street or specified streets not less than 4.5 m wide, or where the building abuts on specified streets not less than 4.5 m wide having different levels, from the mean level of the lower or lowest of such streets, to the mean height of the roof over the highest usable floor space in the building. ( L.N. 406 of 1987 ; L.N. 110 of 2005 ) (2) In determining for the purposes of regulation 20 , 21 or 22 the area of the site on which a building is erected— (a) no account shall be taken of any part of any street or service lane; and (b) there shall be included any area dedicated to the public for the purposes of passage. (3) (a) Subject to subparagraph (b), for the purposes of regulations 19 , 20 , 21 and 22 , the gross floor area of a building shall be the area contained within the external walls of the building measured at each floor level (including any floor below the level of the ground), together with the area of each balcony in the building, which shall be calculated from the overall dimensions of the balcony (including the thickness of the sides thereof), and the thickness of the external walls of the building. (b) In determining the gross floor area for the purposes of regulations 20 , 21 and 22 , the Building Authority may disregard any floor space that he is satisfied is constructed or intended to be used solely for parking motor vehicles, loading or unloading of motor vehicles, or for refuse storage chambers, refuse storage and material recovery chambers, material recovery chambers, refuse storage and material recovery rooms, refuse chutes, refuse hopper rooms and other types of facilities provided to facilitate the separation of refuse to the satisfaction of the Building Authority, or for access facilities for telecommunications and broadcasting services, or occupied solely by machinery or equipment for any lift, air-conditioning or heating system or any similar service. ( L.N. 406 of 1987 ; 39 of 2000 s. 7 ) (4) For the purposes of regulations 19 , 20 , 21 and 22 , the Building Authority may treat as a non-domestic building a composite building in which the only domestic part of the building is a place of residence, not having more than 50 m 2 of usable floor space, for a caretaker or other person employed in connexion with the building or a service provided therefor or a residence comprising the top storey of the building, or both. ( L.N. 294 of 1976 ) ( G.N.A. 97 of 1962 ; L.N. 54 of 1969 ) 23A. Provisions supplementary to regulations 19 , 20 , 21 and 22 in respect of hotels (1) In this regulation— hotel ( 旅館 ) means premises held out as providing sleeping accommodation to any persons presenting themselves who are willing to pay a fee for the sleeping accommodation. ( 6 of 2020 s. 45 ) (2) For the purposes of regulations 19 , 20 , 21 and 22 , the Building Authority may— (a) treat as a non-domestic building a building that he is satisfied is constructed or intended to be used as a hotel ( hotel building ); or (b) treat as a non-domestic part of a composite building the part in the building that he is satisfied is constructed or intended to be used as a hotel ( the hotel part of a building ). (3) In determining the gross floor area of a hotel building or the hotel part of a building for the purposes of regulations 20 , 21 and 22 , the Building Authority may disregard any floor space in that hotel building or the hotel part of that building that he is satisfied is constructed or intended solely for use as— (a) a place for picking up and setting down persons departing from or arriving at the hotel by vehicle; or (b) any of the following— (i) a laundry, a carpentry workshop, a mechanical or electrical workshop; (ii) an area for storing dry goods, food, beverages, linen or furniture; (iii) facilities for the welfare of staff including staff canteen, changing room and rest room for staff; or (iv) other supporting facilities as may be approved by the Building Authority. (4) Without prejudice to section 25 of the Ordinance, where a hotel building has been treated as a non-domestic building or the hotel part of a building has been treated as a non-domestic part of that building under paragraph (2), no person, being the proprietor of the hotel or being the owner or occupier of the hotel building or the hotel part of the building, shall without prior approval of the Building Authority change, or cause to be changed, the use of the hotel building or of the hotel part of the building in whole or in part to a use other than that of a hotel. (5) For the purpose of paragraph (4), if since a hotel building or the hotel part of a building has been put into use— (a) no licence issued under the Hotel and Guesthouse Accommodation Ordinance ( Cap. 349 ) is in effect in respect of the hotel concerned; or ( 6 of 2020 s. 45 ) (b) an order of exclusion is in effect under section 3 of that Ordinance in respect of the hotel concerned, then any use of the hotel building or of the hotel part of the building in whole or in part shall be deemed to be a change of use to a use other than that of a hotel. (6) Without prejudice to section 25 of the Ordinance, where any floor space in a hotel building or the hotel part of a building has been disregarded under paragraph (3) in determining the gross floor area of the hotel building or the hotel part of the building, no person, being the proprietor of the hotel or being the owner or occupier of the hotel building or the hotel part of the building, shall without prior approval of the Building Authority use, or cause to be used, the floor space in whole or in part for any use other than a use mentioned in subparagraph (a) or (b) of that paragraph. (7) Where— (a) the use of a hotel building or of the hotel part of a building in whole or in part is changed in contravention of paragraph (4); or (b) any floor space in whole or in part is used in contravention of paragraph (6), the Building Authority may by order in writing served on the proprietor of the hotel concerned or the owner or occupier of the hotel building or the hotel part of the building require him to discontinue its present use within such time or times as may be specified in the order. (8) Any person who contravenes paragraph (4) or (6) shall be guilty of an offence and shall be liable on conviction to a fine at level 6 and to imprisonment for 2 years; but it shall be a defence in any prosecution for a contravention of any provision referred to in this paragraph for the person charged to prove to the satisfaction of the court that he did not know, nor could reasonably have discovered, the contravention referred to in the charge. (9) Any person who, without reasonable excuse, fails to comply with an order served on him under paragraph (7) shall be guilty of an offence and shall be liable on conviction— (a) to a fine at level 5 and to imprisonment for 1 year; and (b) to a further fine at $5,000 for each day during which it is proved to the satisfaction of the court that failure to comply with the order has continued. ( 39 of 2000 s. 7 ) 24. Height of storeys (1) Every room used or intended to be used for the purpose of an office or for habitation in any building shall have a height of not less than 2.5 m measured from floor to ceiling: ( L.N. 406 of 1987 ) Provided that there shall be not less than 2.3 m measured from the floor to the underside of any beam. (2) In any such room having a sloping ceiling, the height shall be measured to the mean height of such ceiling above floor level: Provided that no portion of any room shall have a height of less than 2 m. (3) (Repealed L.N. 406 of 1987 ) ( L.N. 294 of 1976 ) 25. Space about domestic buildings (1) (a) Every domestic building on a class A or B site or on a class C site shall have within the site an open space at the rear, or partly at the rear and partly at the side, at a level of not less than 150 mm below the floor of the lowermost storey in accordance with the Second Schedule : Provided that where the Building Authority considers it necessary for proper and equitable development or redevelopment of an adjacent site, he may require the provision of more open space than that specified in the Second Schedule . ( G.N.A. 97 of 1962 ; L.N. 82 of 1963 ) (b) The open space provided pursuant to subparagraph (a) shall be such that no part of the building which bounds on such open space at any level shall be within 1.5 m, measured horizontally, of a line drawn vertically from a point in the boundary of the open space immediately opposite thereto. ( L.N. 33 of 1966 ) (2) No part of any domestic building shall be erected within 1.5 m of the rear boundary of the site. The open space so provided shall be counted as part of the open space required under this regulation. ( L.N. 33 of 1966 ) (3) No existing domestic building which has an open space of equal or less area than that required by this regulation shall be altered in such manner as to reduce the existing amount of open space. (4) No existing domestic building which has a greater area of open space than that required by this regulation shall be altered in such a manner as to reduce the area of open space to less than that required by this regulation. (5) Where any open space or area is at a level more than 600 mm below an adjoining open space, safe parapet walls, railings or fences shall be provided by the person creating the difference in levels. (6) Access shall be provided to every open space. ( L.N. 294 of 1976 ) 26. New buildings on existing street less than 4.5 m wide to be set back from centre line of street Where the width of an existing street in front of any new building is less than 4.5 m, no part of such building shall be nearer to the centre line of the street than 2.25 m. ( G.N.A. 83 of 1959 ; L.N. 294 of 1976 ; L.N. 144 of 1978 ) 27. Cuttings (1) No building shall be built to abut against a cutting, including a toe wall supporting a cutting. (2) A clear intervening space or area of a width of not less than 1/4 of the height of the cutting shall be left between such building at ground floor level and the toe of the cutting. (3) Such intervening space or area shall in no case be less than 2.5 m in width. ( L.N. 294 of 1976 ) (4) For the purposes of this regulation the height of the cutting shall be deemed to be the height measured on a vertical line drawn from the toe of such cutting, and extending from the finished ground or concreted surface to a point where it meets a line drawn downwards at an angle of 30 degrees with the horizontal from the top of the cutting. 28. Service lanes (1) In addition to any open space required under regulation 25 every domestic building shall be provided with a service lane at the rear or side of such building: Provided that a service lane shall not be required— (a) where a public lane not less than 3 m wide or a street already exists; (b) for detached and semi-detached buildings; (c) where exempted by the Building Authority. (2) Every such service lane shall be accessible from an existing street but where such access is not immediately possible, this regulation shall be deemed to have been complied with if access would be obtained in the event of future development or redevelopment of other lots within the block. ( L.N. 159 of 1990 ) (3) The alignment, width and levels of every such lane shall be decided by the Building Authority who may grant a modification of regulation 25 when a lane exceeding 1.5 m in width is required. ( L.N. 54 of 1969 ; L.N. 294 of 1976 ) Part IIIA Access Facilities for Telecommunications and Broadcasting Services (Part IIIA added 39 of 2000 s. 7 ) (Format changes— E.R. 5 of 2020 ) 28A. Access facilities for telecommunications and broadcasting services Every commercial building, industrial building, residential building (other than a building for the residence of a single family) and hotel building shall be provided with access facilities for telecommunications and broadcasting services in accordance with the design requirements as may be specified by the Building Authority from time to time. Part IV Lighting and Ventilation (Format changes— E.R. 5 of 2020 ) 29. Lighting and ventilation Every storey of every building used or intended to be used for the purpose of an office or for habitation shall be provided with effectual means of lighting and ventilation. ( G.N.A. 83 of 1959 ) 30. Lighting and ventilation of rooms used or intended to be used for habitation or as an office or kitchen (1) Every room used for habitation or for the purposes of an office or as a kitchen shall be provided with natural lighting and ventilation. ( G.N.A. 97 of 1962 ) (2) Such natural lighting and ventilation shall be provided by means of one or more windows which shall be— (a) so constructed that— (i) the aggregate superficial area of glass in the window or windows is not less than one-tenth of the area of the floor of the room; and (ii) the windows can, to an extent at least equal in the aggregate to one-sixteenth of the area of the floor of the room, be opened in such manner that the top of the opening of each window is at least 2 m above the level of the floor or, in the case of detached and semi-detached buildings, at least 1.9 m above the level of the floor; and ( L.N. 294 of 1976 ) (b) such that not less than the area required by subparagraph (a)(i) (hereinafter referred to as the prescribed window) faces directly into the external air. ( G.N.A. 83 of 1959 ) 31. Minimum requirements of window (1) No prescribed window shall, for the purposes of regulation 30 , be deemed to face into the external air unless— (a) it faces into a street which is not less than 4.5 m wide; or (b) it faces into a space uncovered and unobstructed above the area delineated by the rectangular horizontal plane; and (c) it is so placed that, if another rectangular plane, the base whereof is equal to and common with the base of the rectangular horizontal plane, is inclined, above the rectangular horizontal plane, at an angle of 71 1/2° from the horizontal where the window is in a room used for habitation or 76° from the horizontal where the window is in a room used for the purposes of an office or as a kitchen, no part of the building, or of any other building within the site on which such building is erected, protrudes above such plane; or ( G.N.A. 97 of 1962 ) (d) where such window opens on to an area bounded on the side opposite the window by a boundary of the site on which the building is erected, such window is so placed that, if the rectangular horizontal plane is projected to such boundary and, from the position at which it first intersects the boundary, another rectangular plane, the base whereof is parallel and level with the sill of the window and has a length equal to the length of the base of the rectangular horizontal plane, is projected, towards the site and above the rectangular horizontal plane, at an angle of 80 1/2° from the horizontal where the window is in a room used for habitation or 83° where the window is in a room used for the purposes of an office or as a kitchen, no part of the building, or of any other building within such site, protrudes above such inclined plane: ( G.N.A. 97 of 1962 ) Provided that, where there is a service lane or street less than 4.5 m wide adjacent to and parallel with such boundary, the boundary shall, for the purposes of this subparagraph be deemed to be at a position 1.5 m beyond such boundary. ( L.N. 54 of 1969 ) (2) The rectangular horizontal plane shall be such that— (a) it has an area of not less than 21 m 2 ; and (b) the minimum length of the base is not less than 2.3 m; and (c) the minimum length of the sides at right angles to the base, between the wall in which the window is sited and any other wall or building opposite thereto within the boundary of the site on which the building is erected, is not less than 4.5 m; or (d) where the window opens on to an area bounded on the side opposite to the window by a boundary of the site on which the building is erected, the minimum length of the sides at right angles to the base, between the wall in which the window is sited and such boundary, is not less than 2.3 m; or (e) where the window opens on to an area bounded on the side opposite to the window by a boundary of the site on which the building is erected and there is a service lane or street less than 4.5 m wide adjacent to and parallel with such boundary, the minimum length of the sides at right angles to the base, between the wall in which the window is sited and a line 1.5 m beyond such boundary or, where such service lane or street is less than 3 m wide, between the wall in which the window is sited and a line drawn along the centre line of the service lane or street, is not less than 2.3 m. ( L.N. 54 of 1969 ; 17 of 2018 s. 53 ) (3) For the purposes of this regulation— (a) base ( 底邊 ), when used in relation to the rectangular horizontal plane, means that side of the rectangular horizontal plane common with the line of the sill of the window; rectangular horizontal plane ( 矩形水平面 ) means a rectangular plane at the level of the sill of the window having the minimum area and minimum dimensions prescribed by paragraph (2) ( L.N. 307 of 1998 ) ; window ( 窗 ) includes french window; and (b) the sill of a prescribed window shall be deemed to be at a level 1 m above the level of the floor of the room for which the prescribed window is provided, whether or not the sill is at such level. ( L.N. 54 of 1969 ) ( G.N.A. 83 of 1959 ; L.N. 294 of 1976 ) 32. Restriction on distance any part of room may be from prescribed window No part of any room used for habitation shall be more than 9 m, measured within the room, from a prescribed window which faces directly into the external air or, where, under and in accordance with regulation 33 , a window opens on to an enclosed verandah or balcony or on to a conservatory or on to any similar enclosed place or is, under regulation 71 , permitted to open on to an unenclosed verandah or balcony or any other unenclosed place, from the outer edge of the verandah, balcony, conservatory or enclosed or unenclosed place, as the case may be. ( G.N.A. 83 of 1959 ; L.N. 294 of 1976 ) 33. Windows opening on to enclosed verandah, etc. Where any room used or intended to be used for habitation or for the purposes of an office has a window which opens on to an enclosed verandah or balcony or on to a conservatory or on to any similar enclosed place, within, in each case, the boundary of the site on which the building is erected, such window shall be deemed to comply with the requirements of regulations 30 and 31 if— (a) such verandah, balcony, conservatory or similar enclosed place is provided with a window which would comply with the requirements of regulations 30 and 31 if it were the window of a room having a floor area equivalent to the aggregate of the areas of the floors of such room and such verandah, balcony, conservatory or similar enclosed place, as the case may be; and (b) the area of glass and the opening in the window of such room is such that, to that extent, such window would comply with the requirements of regulation 30(2)(a) if it were likewise the window of a room having a floor area equivalent to the aggregate of the areas of the floors of such room and such verandah, balcony, conservatory or similar enclosed place. ( G.N.A. 83 of 1959 ; G.N.A. 97 of 1962 ) 34. Mechanical ventilation and artificial lighting of offices Where, owing to the position, level or unsuitable surroundings of any room used or intended to be used for the purposes of an office, the provisions of regulation 31 cannot be complied with, in respect of such room, to the satisfaction of the Building Authority, there shall be provided— (a) a mechanical means of ventilation which shall be capable of supplying fresh air to all parts of such room at a rate of not less than 5 changes of air per hour; and (b) such artificial lighting as the Building Authority may approve. ( G.N.A. 83 of 1959 ) 35. Additional vent may be required (1) Where in the opinion of the Building Authority compliance with the provisions of these regulations will not secure adequate ventilation for any room used for such purposes by reason of its intended use, unsuitable surroundings or other cause he may require that room to be provided with additional ventilation by means of— (a) an aperture or airshaft communicating direct with the open air, having an unobstructed sectional area of not less than 0.015 m 2 ; or ( L.N. 294 of 1976 ) (b) a fanlight which opens to a ventilated lobby or corridor; or (c) such other means of ventilation as shall be approved by him. (2) For the purpose of regulations 29 to 35 , a laundry being part of or used in connexion with any building shall be deemed to be used for the purpose of habitation. 35A. Provision for room-sealed gas water heater in bathrooms (1) Subject to paragraphs (2) and (3), suitable provision shall be made for the installation of a room-sealed gas water heater in every bathroom in a building. (2) Where a room-sealed gas water heater to serve a bathroom is, or is to be, installed in any place in a building other than in the bathroom, suitable provision shall be made for the installation of such room-sealed gas water heater. (3) This regulation shall not apply— (a) to a building in respect of which the Building Authority has, or is deemed to have, approved the plan of building works under this Ordinance on or before 20 May 1983; or (b) to a building which is designed, to the satisfaction of the Building Authority, to have available therein a centralized hot water supply. (4) For the purposes of this regulation— room-sealed gas water heater ( 密封式氣體熱水爐 ) means a gas water heater which, when in operation, has the combustion air inlet and the combustion products outlet isolated from the room or place in which the gas water heater is installed; suitable provision ( 適當設施 ) means an adequate aperture in an external wall, to the satisfaction of the Building Authority, to provide direct access to the external air in respect of a room-sealed gas water heater which is or may be installed, and which aperture is capable of being sealed with a readily removable cover when a room-sealed gas water heater is not installed. ( L.N. 143 of 1983 ) 36. Rooms containing soil fitments (1) Every room containing a soil fitment or waste fitment shall be provided with a window or lantern light. (2) Every such window or lantern light shall be such that— (a) the aggregate superficial area of glass therein is not less than the equivalent of one-tenth of the area of the floor of the room; and (b) a part thereof, not less in area than the equivalent of one-tenth of the area of the floor of the room, can be opened directly into the open air. (3) The top of that part of any such window which, in accordance with paragraph (2), is designed to open shall be not less than 2 m above the level of the floor of the room. ( L.N. 294 of 1976 ) (4) No room containing a soil fitment shall open directly into a room used or intended to be used for the manufacture, preparation or storage of food for human consumption or into the auditorium or any space in a place of public entertainment in which persons await admission to public entertainment. ( L.N. 194 of 1996 ) (5) For the purposes of this regulation, the expression, soil fitment ( 便溺污水設備 ) means a water-closet fitment, a trough water-closet or a urinal. ( G.N.A. 83 of 1959 ; G.N.A. 97 of 1962 ) 37. Light and air not to be diminished No building shall be erected in such a manner as to reduce the quantity of light and air available to any other building, which has been erected in accordance with these regulations, below that required under these regulations. Part V Staircases, Fire Escapes and Access for Firefighting and Rescue Purposes ( L.N. 170 of 1992 ) (Format changes— E.R. 5 of 2020 ) 38. (Repealed L.N. 439 of 1990 ) 39. Staircases (1) Every building which exceeds 1 storey in height shall be provided with a staircase or staircases to give access to upper floors unless there is separate access to such upper floors. (2) The main staircase of every building which exceeds 4 storeys in height shall be continued to the roof of the building unless a secondary staircase of fire escape is provided. (3) The main staircase of every building which exceeds 1 storey in height shall— (a) have a clear height of not less than 2 m; (b) have a clear width of not less than 900 mm; (c) be constructed with treads not less than 225 mm in width (measured at the centre of the flight) from the face of one riser to the face the next riser and with risers not exceeding 175 mm in height; (d) have not more than 16 steps in any flight without the introduction of a landing; (e) be provided on one or both sides with properly fixed handrails which, in section, shall be— (i) if tubular, not less than 38 mm and not greater than 50 mm in external diameter; (ii) if rectangular, not less than 40 mm and not more than 50 mm wide with an overall depth, or depth to a deep groove, of not more than 50 mm; (iii) in any other case, such as to afford to the user thereto a grip analogous to that specified in the case of either tubular or rectangular handrails, whichever may be the more appropriate having regard to the shape of the section; ( L.N. 365 of 1984 ; E.R. 5 of 2020 ) (f) be so arranged as to provide access to a street or to an open space leading thereto; and (g) if continued to the roof of the building as a means of escape in case of fire be provided with a door at this level, such door to be glazed in the upper panels. ( L.N. 294 of 1976 ) 40. Staircases in buildings intended for separate occupation In any building intended for separate occupation by more than 2 tenants, the staircase intended for common use shall be provided with adequate natural lighting at each storey above the ground floor and be ventilated at least at its highest point. ( L.N. 439 of 1990 ) 40A. Escalator to be in addition to staircases or means of escape in case of emergency (1) Where an escalator is installed in any building, it shall be in addition to— (a) any staircase required by regulation 39 ; and (b) the means of escape in case of emergency and second staircase required by regulation 41 . (2) An escalator shall not be a staircase, passage or other normal means of egress for the purposes of regulation 43 . ( L.N. 97 of 1994 ) 41. Means of escape (1) Every building shall be provided with such means of escape in case of emergency as may be required by the intended use of the building. (2) Without prejudice to paragraph (1), every building which exceeds 6 storeys in height or in which the level of the floor of the uppermost storey is more than 17 m above the level of the ground at the point of discharge of the main staircase shall, in addition to the main staircase, be provided with a second staircase as means of escape in case of emergency. ( L.N. 294 of 1976 ) ( L.N. 33 of 1966 ) 41A. Access staircases for firemen (1) Subject to paragraph (4), every building that exceeds 1 storey in height shall be provided with an adequate number of staircases, so designed and constructed as to allow firemen safe and unobstructed access to all floors of the building in the event of a fire ( access staircases ). (2) In determining what is, in respect of a building, an adequate number of access staircases, regard shall be had to the intended use of the building and the size of each floor. (3) The access staircase or staircases in a building shall be so designed and constructed that, in the event of a fire— (a) an adequate number of firemen, with equipment, may reach the fire; and (b) firemen using the staircase or staircases are adequately protected from fire and smoke. (4) This regulation does not apply to a building not exceeding 3 main storeys in height that is used or intended to be used solely for domestic purposes and constituting a single household unit. ( L.N. 170 of 1992 ) 41B. Fireman’s lifts (1) Subject to paragraph (4), every building exceeding 2 storeys in height shall be provided with at least such number of lifts designed and installed to be used by firemen in the event of a fire ( fireman’s lift ) as will ensure that no part of the floors that they serve are more than 60 m from such a lift. (2) (Repealed L.N. 136 of 1995 ) (3) Fireman’s lifts provided in accordance with this regulation shall— (a) be so designed and installed that at least every alternate floor of the building is served by at least one fireman’s lift; (b) be of an adequate size, and have adequately sized doors, for use by firemen with their equipment; (c) be enclosed by a liftwell that encloses no more than 3 fireman’s lifts and no other lifts; (d) be so designed and installed that, in the event of a fire, firemen using the lifts are adequately protected from fire and smoke, particularly when leaving the lifts; (e) be so designed and installed that in the event of a fire, firemen can gain exclusive control and operation of the lifts so that firemen with their equipment can easily, conveniently, safely and speedily reach the fire; and (f) be so designed, located and installed that, in the event of a fire, firemen can have safe and unobstructed access to the lifts and to the floors served by the lifts. ( L.N. 136 of 1995 ) (4) This regulation does not apply to— (a) a building— (i) provided with only 1 staircase; (ii) not exceeding 6 storeys in height; and (iii) in which the level of the floor of the uppermost storey is not more than 17 m above the level of the ground at the point of discharge of the staircase; (b) a domestic building not exceeding a height of 30 m; or ( L.N. 136 of 1995 ) (c) a non-domestic building or the non-domestic part of a composite building— (i) in which no industrial undertaking is being, or is intended to be carried on and which is not used or intended to be used for bulk storage or as a warehouse, place of public entertainment, hotel or guesthouse, or hospital; and ( 6 of 2020 s. 46 ) (ii) either— (A) not exceeding a height of 15 m; or (B) exceeding a height of 15 m but neither exceeding a height of 30 m nor a cubical extent of 7 000 m 3 . ( L.N. 136 of 1995 ) (5) For the purposes of paragraph (4)(b) or (c), the height of a building shall be measured in accordance with regulation 23(1) . (6) In this regulation— cubical extent ( 體積 ), in relation to a building, means the space contained within the external surfaces of its walls and roof and the upper surface of the floor of its lowest storey, excluding any space within any enclosure on the roof used exclusively for accommodating a water tank or lift gear or any other services, and, if any side of the building is not enclosed by a wall, that side shall be deemed to be enclosed by a wall extending downwards from the outer edge of the roof; hotel or guesthouse ( 酒店或賓館 ) has the meaning given by section 2A of the Hotel and Guesthouse Accommodation Ordinance ( Cap. 349 ); ( 6 of 2020 s. 46 ) industrial undertaking ( 工業經營 ) has the same meaning as in section 2 of the Factories and Industrial Undertakings Ordinance ( Cap. 59 ). ( L.N. 170 of 1992 ; L.N. 136 of 1995 ; L.N. 194 of 1996 ; 6 of 2020 s. 46 ) 41C. Firefighting and rescue stairway (1) This regulation applies to— (a) every building exceeding— (i) a height of 30 m; or (ii) a cubical extent of 7 000 m 3 and a height of 1 storey, in which an industrial undertaking is being, or is intended to be carried on or which is used, or is intended to be used for bulk storage or as a warehouse; and (b) every basement— (i) exceeding a cubical extent of 7 000 m 3 ; and (ii) either— (A) exceeding a height of 2 storeys; or (B) exceeding a depth of 9 m from the floor level of the ground storey above the basement to the floor level of the lowest storey in the basement. ( L.N. 136 of 1995 ) (2) Every building or basement to which this regulation applies shall be provided with at least such number of firefighting and rescue stairways as will ensure that no part of the building (including any basement in the building) or basement is more than 60 m from such a stairway. (3) Subject to paragraph (4A), every firefighting and rescue stairway shall be so designed and constructed that— (a) no lift other than a fireman’s lift is installed in the stairway; (b) not more than 3 fireman’s lifts are installed in the stairway; (c) if the roof is accessible by a staircase, the access staircase of the stairway serves the roof; (d) in the event of a fire, firemen may have safe and unobstructed access— (i) to all floors; and (ii) if subparagraph (c) applies, to the roof; and (e) firemen using the stairway are adequately protected from fire and smoke. ( L.N. 136 of 1995 ) (4) For the purposes of paragraph (1)(a) , the height of a building shall be measured in accordance with regulation 23(1) . (4A) A fireman’s lift in a firefighting and rescue stairway is not required to serve the top floor of a building to which this regulation applies if the Building Authority is satisfied that there is no practicable alternative to locating the machine room for the lift on that floor. ( L.N. 136 of 1995 ) (5) In this regulation— access staircase ( 通道樓梯 ) has the same meaning as in regulation 41A ; basement ( 地庫 ) means any storey of a building below the ground storey and from which any exit route required by or under these regulations is in an upward direction; cubical extent ( 體積 ) has the same meaning as in regulation 41B ; firefighting and rescue stairway ( 消防和救援樓梯間 ) means a stairway accommodating an access staircase and a fireman’s lift; fireman’s lift ( 消防員升降機 ) has the same meaning as in regulation 41B ; ground storey ( 地面樓層 ) means the storey in which is situated an entrance from a street to the building and, where a building fronts or abuts on more than one street and due to a difference in street levels there are 2 or more entrances serving different streets and situated in different storeys, means each such storey. ( L.N. 170 of 1992 ) 41D. Emergency vehicular access (1) Every building shall be provided with an emergency vehicular access which is so designed and constructed as— (a) to allow safe and unobstructed access of a vehicle of the Fire Services Department to the building; and (b) to provide for the safe operation of such a vehicle, in the event of a fire or other emergency. (2) The design and construction of an emergency vehicular access shall be in accordance with such requirements as may be specified by the Building Authority from time to time having regard to the intended use of the building. (3) The Building Authority may exempt a building from any or all of such requirements on design and construction if the Building Authority is satisfied that compliance with the requirement or requirements

    The text continues in the official source.

    Related guides, FAQ and contract templates