LEGALDIGMLEGALDIGM
    ← British Columbia, Canada
    Beta
    BC:14_2015:en

    BC:14_2015:en — Energy Efficiency Standards Regulation

    Beta. Legal information, not legal advice. LEGALDIGM is not a law firm. Check the official source for the current text.

    Analyze this law with AI
    Definitions 1 In this regulation: Act means the Energy Efficiency Act ; ANSI means the American National Standards Institute; applicable efficiency standard , in relation to an energy device, means each efficiency standard that applies to the energy device under section 7 [prescribed efficiency standards] or, if applicable, section 8 [early adoption of future efficiency standards] ; ASTM means the American Society for Testing and Materials International; ASTM C518-04 means ASTM standard ASTM C518-04 entitled Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ; ASTM C518-10 means ASTM standard ASTM C518-10 entitled Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ; BTU means British thermal units; CIE means the Commission internationale de l'éclairage, or International Commission on Illumination; CSA means the Canadian Standards Association; designated tester , in relation to an energy device, means a person, agency or organization that, under section 4 [designated testers] , is designated and authorized to verify the energy device; efficiency standards table means a table referred to in section 2 [prescribed energy devices] ; energy efficiency verification label means a label required under section 5 (1); federal Act means the Energy Efficiency Act (Canada) ; federal minister has the same meaning as "Minister" in the federal Act; federal regulation means the Energy Efficiency Regulations, 2016 made under the federal Act; IEC means the International Electrotechnical Commission; ISO means the International Organization for Standardization; ISO/IEC 17065 means ISO/IEC standard ISO/IEC 17065 entitled Conformity assessment — Requirements for bodies certifying products, processes and services ; label means a printed decal, stamped plate or other permanent marking; manufactured fenestration product means an energy device referred to in column 1 of the efficiency standards table in section 27 [efficiency standards for manufactured fenestration products] ; manufacturing information label means a label required under section 6 (1); NFRC means the National Fenestration Rating Council; RSI means an R-value expressed in SI units of metre squared Kelvin per watt, or m 2 ×K/W; verify means applying a testing procedure to determine whether an energy device meets an applicable efficiency standard. [am. B.C. Regs. 29/2018, Sch. 1, s. 1; 35/2021, s. 1.] Prescribed energy devices 2 For the purpose of the definition of "energy device" in section 1 of the Act, the products referred to in column 1 of the efficiency standards tables in the following sections are prescribed: a section 15 [efficiency standards for compact audio products, televisions, video products and consumer battery charging systems] ; b section 27 [efficiency standards for manufactured fenestration products] ; c section 30 [efficiency standards for household appliances] ; d section 34 [efficiency standards for heating, ventilation and air conditioning products] ; e section 38 [efficiency standards for water heaters] ; f section 41 [efficiency standards for lighting products] ; g section 47 [efficiency standards for general purpose electric motors] ; h section 54 [efficiency standards for desktop computers, mobile gaming systems and thin clients] ; i section 63 [efficiency standards for notebook computers and portable all-in-one computers] ; j section 69 [efficiency standards for computer monitors] ; k section 74 [efficiency standards for high expandability computers, mobile workstations, small-scale servers and workstations] . [am. B.C. Reg. 35/2021, s. 2.] Prescribed date 3 For the purpose of section 2 (3) (a) [exemption from section 2 (1) of Act] of the Act, the prescribed date for an energy device referred to in column 1 in an item of an efficiency standards table is the date set out in column 2 opposite the energy device. Designated testers 4 1 In this section, certification program means a program of verification using standard testing procedures. 2 For the purposes of verifying an energy device, the following persons, agencies or organizations are designated, and authorized as indicated, to make the verification: a inspectors designated under section 3 (1) [inspection and testing] of the Act are authorized to verify any energy device; b persons or organizations accredited by the Standards Council of Canada as certification bodies are authorized to verify any energy device to which the certification relates; c agencies accredited by the NFRC as independent certification and inspection agencies are authorized to verify any manufactured fenestration product; d professional engineers, and architects authorized to practise in British Columbia, are authorized to verify the following: i door slabs referred to in column 1 in item 1 of the efficiency standards table in section 27 [efficiency standards for manufactured fenestration products] ; ii glazing products referred to in column 1 in item 2 of the efficiency standards table in section 27; iii manufactured fenestration products, other than door slabs and glazing products referred to in subparagraphs (i) and (ii) of this paragraph, that A are designed for a specific building, or B fall outside the scope of a certification program; e certification bodies are authorized to verify any computer or computer monitor if the certification bodies i are accredited under an International Accreditation Forum Multilateral Recognition Arrangement based on ISO/IEC 17065, and ii maintain an internet accessible product listing. 3 Professional engineers and architects referred to in subsection (2) (d) must a verify manufactured fenestration products referred to in subsection (2) (d) (iii) (A) of this section in the manner described in section 25 [efficiency standard exemption for manufactured fenestration products designed for specific buildings] , and b verify manufactured fenestration products referred to in subsection (2) (d) (iii) (B) of this section in the manner described in section 26 [calculation of U-value for atypical manufactured fenestration products] . [am. B.C. Reg. 35/2021, s. 3.] Energy efficiency verification label 5 1 For the purpose of section 2 (1) (b) [prescribed label] of the Act, every energy device, other than an energy device referred to in subsection (2) of this section, must have affixed to it an energy efficiency verification label that indicates, by way of a registered trademark, wordmark or symbol of a designated tester, that the designated tester has a verified the energy device, and b determined that the energy device meets the applicable efficiency standards. 2 An energy efficiency verification label is not required for an energy device in respect of which one of the following sections of this regulation applies: a section 13 [label exemption for compact audio products, televisions and video products compliant with federal Act] ; b section 14 [label exemption for consumer battery charging systems with California label] ; c section 24 [label exemption for manufactured fenestration products designed for specific buildings] ; d section 29 [label exemption for clothes washers, dishwashers, refrigerators, combination refrigerator-freezers and freezers compliant with federal Act] ; e section 32 [label exemption for gas furnaces compliant with federal Act] ; e.1 section 32.1 [label exemption for commercial gas boilers with reported information or compliant with federal Act] ; f section 36 [label exemption for water heaters compliant with federal Act] ; g section 39.2 [label exemption for certain lamps compliant with federal Act] ; h section 53 [label exemption for desktop computers, mobile gaming systems and thin clients with certification report] ; i section 62 [label exemption for notebook computers and portable all-in-one computers with certification report] ; j section 68 [label exemption for computer monitors with certification report] ; k section 73 [label exemption for high expandability computers, mobile workstations, small-scale servers and workstations with certification report] . 3 A person placing an energy efficiency verification label on an energy device, other than an energy device to which section 33.2 [placement of label on vented gas fireplace heaters and vented decorative gas appliances] applies, must affix the label so that the label is easily and readily seen on the energy device without the need to remove any covering. [am. B.C. Regs. 29/2018, Sch. 1, s. 2; 35/2021, s. 4.] Manufacturing information label 6 1 For the purpose of section 2 (1) (b) [prescribed label] of the Act, the manufacturer of an energy device made in British Columbia, and the importer of an energy device not made in British Columbia, must affix to the energy device or the packaging of the energy device a manufacturing information label that sets out a the manufacturer's name or identification, and b the date of manufacture or a date code. 2 A person placing a manufacturing information label on the packaging of an energy device must affix the label so that the label can be easily and readily seen without the need to remove any covering. [en. B.C. Reg. 29/2018, Sch. 1, s. 3; am. B.C. Reg. 35/2021, s. 5.] Prescribed efficiency standards 7 1 For an energy device referred to in column 1 in an item of an efficiency standards table, a the efficiency standards for the energy device are the applicable standards set out or referred to in column 4 opposite that energy device, b the testing procedures that must be used to determine whether the energy device meets an efficiency standard referred to in paragraph (a) are the applicable testing procedures set out or referred to in column 5 opposite the efficiency standard, and c subject to section 8 [early adoption of future efficiency standards] , an efficiency standard referred to in paragraph (a) of this subsection and the corresponding testing procedure referred to in paragraph (b) of this subsection apply to the energy device if the energy device is manufactured during the period set out in column 3 opposite that energy device. 2 Despite subsection (1), a the efficiency standard for a manufactured fenestration product referred to in section 25 [efficiency standard exemption for manufactured fenestration products designed for specific buildings] may be met by the method set out in that section, b the efficiency standard for a manufactured fenestration product referred to in section 26 [calculation of U-value for atypical manufactured fenestration products] may be met by the method set out in that section, and c in addition to meeting the efficiency standards referred to in subsection (1) (a) of this section, a fluorescent lamp ballast to which section 40 [additional efficiency standard for fluorescent lamp ballasts] applies must meet the efficiency standard referred to in subsection (2) of that section. Early adoption of future efficiency standards 8 For the purposes of section 2 [efficiency standards of energy devices] of the Act, if 2 or more items in an efficiency standards table refer to the same energy devices in column 1 and a one of the items in the efficiency standards table sets out an efficiency standard in column 4 and a corresponding testing procedure in column 5 that apply to the energy devices if they are manufactured during the period set out in column 3 opposite the energy devices, and b one or more of the other items in that efficiency standards table set out an efficiency standard in column 4 and a corresponding testing procedure in column 5 that would apply to the energy devices if they were manufactured after the period referred to in paragraph (a) of this section, the efficiency standard for the energy devices referred to in paragraph (a) of this section may be met by meeting an efficiency standard referred to in paragraph (b) of this section. Verification report 9 1 In this section, verification report means a report issued by a designated tester indicating that the designated tester has a verified an energy device, and b determined that the energy device meets the applicable efficiency standards. 2 A verification report is evidence that an energy device meets the applicable efficiency standards. Exemption from Act and regulation 10 The Act and this regulation do not apply to a a person who manufactures an energy device in British Columbia, or b a person who manufactures any thing in British Columbia that incorporates into it an energy device, if that energy device or thing is manufactured for export from British Columbia. Definitions 11 In this Part: C381.2-17 means CSA standard C381.2-17 entitled Energy performance of battery-charging systems and uninterruptible power supplies ; CAN/CSA C381.2-14 means CSA standard CAN/CSA C381.2-14 entitled Test method for determining the energy efficiency of battery-charging systems ; CAN/CSA C62301-07 means CSA standard CAN/CSA C62301-07 entitled Household Electrical Appliances — Measurement of Standby Power ; CAN/CSA C62301-11 means CSA standard CAN/CSA C62301-11 entitled Household electrical appliances — Measurement of standby power ; compact audio product has the same meaning as in the federal regulation; consumer battery charging system means a battery charging system, including a battery charging system built into another product, that a has an input capacity of less than 2 kW, and b is distributed primarily for personal use by individuals, but does not include a battery charging system excluded under section 12; E 24 , in relation to a consumer battery charging system, means the energy consumption of the consumer battery charging system, in watt-hours, over a 24 hour period when the consumer battery charging system is charging or maintaining the batteries; E b , in relation to a consumer battery charging system, means the total capacity, in watt-hours, of all the batteries in the system; E batt , in relation to a consumer battery charging system, means the energy, in watt-hours, delivered by the consumer battery charging system; N , in relation to a consumer battery charging system, means the number of charger ports; P M , in relation to a consumer battery charging system, means power usage in maintenance mode, which is the state the consumer battery charging system is in when a the consumer battery charging system is connected to the main electricity supply, and b the battery is fully charged, but is still connected to the consumer battery charging system; P O , in relation to a consumer battery charging system, means power usage in no-battery mode, which is the state the consumer battery charging system is in when a the consumer battery charging system is connected to the main electricity supply, b the consumer battery charging system is not connected to the battery, and c each manual on-off switch, if any, is turned on; UEC , in relation to a consumer battery charging system, means the unit energy consumption of the consumer battery charging system expressed in kilowatt-hours per year, or kWh/yr; video product has the same meaning as in the federal regulation. [am. B.C. Reg. 29/2018, Sch. 1, s. 4.] Excluded consumer battery charging systems 12 For the purpose of the definition of "consumer battery charging system" in section 11, the following are excluded: a an inductive battery charging system that uses i less than one watt in maintenance mode, ii less than one watt in no-battery mode, and iii an average of one watt or less over the duration of the charge and maintenance mode test as determined under section 5.8 of CAN/CSA C381.2-14; b a battery charging system incorporated into an uninterruptible power supply system that uses no more than 0.8 + 0.0021 × E b watts in maintenance mode; c a battery analyzer or battery charging system for use in medical devices and exit signs; d a battery charging system built into another product, if the other product is an energy device; e a battery charging system that relies on solar energy or winding-up as its sole source of power. Label exemption for compact audio products, televisions and video products compliant with federal Act 13 An energy efficiency verification label is not required for an energy device that is a compact audio product, television or video product if, in respect of the energy device, a the information required under section 5 (1) [information to be provided by dealers] of the federal Act has been provided to the federal minister, or b the manufacturer of the energy device provides a copy of the information required under section 5 (1) of the federal Act to an inspector designated under section 3 [inspection and testing] of the Act. [am. B.C. Reg. 29/2018, Sch. 1, s. 5.] Label exemption for consumer battery charging systems manufactured on or after June 13, 2018 14 An energy efficiency verification label is not required for a consumer battery charging system manufactured on or after June 13, 2018. [en. B.C. Reg. 29/2018, s. 6.] Efficiency standards for compact audio products, televisions, video products and consumer battery charging systems 15 The following efficiency standards table sets out the efficiency standards for energy devices that are compact audio products, televisions, video products and consumer battery charging systems: Item Column 1 Energy Device Column 2 Prescribed Date (s. 2 (3) (a) of Act) Column 3 Manufacturing Period Column 4 Efficiency Standard Column 5 Testing Procedure 1 Compact audio products Jan 1, 2013 Products manufactured between Jan 2, 2013 and June 1, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active; (b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive; (c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display; (d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-07 tested at 115 volts, regardless of the nominal voltage of the energy device 1.1 Compact audio products June 1, 2018 Products manufactured on or after June 2, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active; (b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive; (c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display; (d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-11, tested at 115 volts, regardless of the nominal voltage of the energy device 2 Televisions Jan 1, 2013 Products manufactured between Jan 2, 2013 and June 1, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active; (b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive; (c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display; (d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-07, tested at 115 volts, regardless of the nominal voltage of the energy device 2.1 Televisions June 1, 2018 Products manufactured on or after June 2, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active; (b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive; (c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display; (d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-11, tested at 115 volts, regardless of the nominal voltage of the energy device 3 Video products Jan 1, 2013 Products manufactured between Jan 2, 2013 and June 1, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active; (b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive; (c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display; (d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-07, tested at 115 volts, regardless of the nominal voltage of the energy device 3.1 Video products June 1, 2018 Products manufactured on or after June 2, 2018 Must be capable of entering each of the following modes that are applicable to the individual product: (a) a standby mode with a power consumption of ≤ 1 watt, with information or status display active; (b) a standby mode with a power consumption of ≤ 0.5 watts, with information or status display inactive; (c) a standby mode with a power consumption of ≤ 0.5 watts, without information or status display; (d) an off mode with a power consumption of ≤ 0.5 watts. CAN/CSA C62301-11, tested at 115 volts, regardless of the nominal voltage of the energy device 4 Consumer battery charging systems with E b ≤ 2.5 watt-hours (for exclusions, see section 12) May 31, 2015 Products manufactured between June 1, 2015 and June 12, 2018 E 24 must be ≤ (16 × N) watt-hours P M + P O must be ≤ (N + 0.0021 × E b ) watt-hours CAN/CSA C381.2-14 CAN/CSA C381.2-14 5 Consumer battery charging systems with E b > 2.5 watt-hours but ≤ 100 watt-hours (for exclusions, see section 12) May 31, 2015 Products manufactured between June 1, 2015 and June 12, 2018 E 24 must be ≤ (12 × N + 1.6 × E b ) watt-hours P M + P O must be ≤ (N + 0.0021 × E b ) watt-hours CAN/CSA C381.2-14 CAN/CSA C381.2-14 6 Consumer battery charging systems with E b > 100 watt-hours but ≤ 1 000 watt-hours (for exclusions, see section 12) May 31, 2015 Products manufactured between June 1, 2015 and June 12, 2018 E 24 must be ≤ (22 × N + 1.5 × E b ) watt-hours P M + P O must be ≤ (N + 0.0021 × E b ) watt-hours CAN/CSA C381.2-14 CAN/CSA C381.2-14 7 Consumer battery charging systems with E b > 1 000 watt-hours (for exclusions, see section 12) May 31, 2015 Products manufactured between June 1, 2015 and June 12, 2018 E 24 must be ≤ (36.4 × N + 1.486 × E b ) watt-hours P M + P O must be ≤ (N + 0.0021 × E b ) watt-hours CAN/CSA C381.2-14 CAN/CSA C381.2-14 8 Consumer battery charging systems with E batt ≤ 5 watt-hours that are designed for use in wet environments and have inductive connections (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 3.04 kWh/yr C381.2-17 9 Consumer battery charging systems, other than systems referred to in item 8, with E batt < 100 watt-hours and battery voltage of < 4 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.1440 × E batt + 2.95 kWh/yr C381.2-17 10 Consumer battery charging systems, other than systems referred to in item 8, with E batt < 100 watt-hours and battery voltage of ≥ 4 volts but ≤ 10 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 When E batt is < 10 watt-hours, UEC must be ≤ 1.42 kWh/yr When E batt is ≥ 10 watt-hours, UEC must be ≤ 0.0255 × E batt + 1.16 kWh/yr C381.2-17 C381.2-17 11 Consumer battery charging systems, other than systems referred to in item 8, with E batt < 100 watt-hours and battery voltage of > 10 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.11 × E batt + 3.18 kWh/yr C381.2-17 12 Consumer battery charging systems with E batt ≥ 100 watt-hours but ≤ 3 000 watt-hours and battery voltage of < 20 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.0257 × E batt + 0.815 kWh/yr C381.2-17 13 Consumer battery charging systems with E batt ≥ 100 watt-hours but ≤ 3 000 watt-hours and battery voltage of ≥ 20 volts (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.0778 × E batt + 2.4 kWh/yr C381.2-17 14 Consumer battery charging systems with E batt > 3 000 watt-hours (for exclusions, see section 12) June 12, 2018 Products manufactured on or after June 13, 2018 UEC must be ≤ 0.0502 × E batt + 4.53 kWh/yr C381.2-17 [am. B.C. Regs. 29/2018, Sch. 1, s. 7; 35/2021 s. 7.] Definitions and interpretation 16 1 In this Part: ASHRAE means the American Society of Heating, Refrigeration and Air-Conditioning Engineers; CAN/CSA A440.2-04/A440.3-04 means CSA standard CAN/CSA A440.2-04/A440.3-04 entitled Energy Performance of Windows and Other Fenestration Systems ; CAN/CSA A440.2-09/A440.3-09 means CSA standard CAN/CSA A440.2-09/A440.3-09 entitled Fenestration energy performance ; CAN/CSA A440.2-14/A440.3-14 means CSA standard CAN/CSA A440.2-14/A440.3-14 entitled Fenestration energy performance ; CAN/CSA A440.2-19/A440.3-19 means CSA standard CAN/CSA A440.2-19/A440.3-19 entitled Fenestration energy performance ; designated heritage building means a building that is a on a Provincial heritage site within the meaning of the Heritage Conservation Act or otherwise included in the Provincial heritage register under that Act, b protected through heritage designation or included in a community heritage register by a local government under the Local Government Act , c protected through heritage designation or included in the heritage register by the Council under the Vancouver Charter , or d protected through heritage designation or included in a community heritage register by the trust council or a local trust committee under the Islands Trust Act ; energy compliant building means a building that a is not a smaller building, and b meets one of the following: i ASHRAE standard ASHRAE 90.1 (2010, 2013, 2016, 2019 or 2022) entitled Energy Standard for Buildings Except Low-Rise Residential Buildings ; ii ASHRAE standard ASHRAE 189.1 (2014 or 2017) entitled Standard for the Design of High-Performance Green Buildings ; iii the National Energy Code of Canada for Buildings 2011, 2015, 2017 or 2020; larger building means a a residential building that has i 4 or more storeys, or ii floor space of more than 600 m 2 , or b a non-residential building; NFRC 100-2004 means NFRC standard NFRC 100-2004 entitled Procedure for Determining Fenestration Product U-Factors ; NFRC 100-2010 means NFRC standard NFRC 100-2010 entitled Procedure for Determining Fenestration Product U-Factors ; NFRC 100-2014 means NFRC standard NFRC 100-2014 entitled Procedure for Determining Fenestration Product U-factors ; NFRC 100-2017 means NFRC standard NFRC 100-2017 entitled Procedure for Determining Fenestration Product U-factors ; residential building means a building with at least one residential unit; smaller building means a residential building that has a less than 4 storeys, or b floor space of 600 m 2 or less; U-value means a measure of heat transfer expressed in watts per metre squared Kelvin, or W/[m 2 ×K]. 2 Door slabs referred to in column 1 in item 1 of the efficiency standards table in section 27 [efficiency standards for manufactured fenestration products] a include only those door slabs that separate heated space from non-heated space, and b do not include door slabs referred to in section 17 [excluded door slabs] . 3 Glazing products referred to in column 1 in item 2 of the efficiency standards table in section 27 a include only those glazing products that i are for installation in door slabs, sidelites or transoms, and ii separate heated space from non-heated space, and b do not include products referred to in section 18 [excluded glazing products] . 4 Non-metal, non-wood framed windows and sliding glass doors (for smaller buildings) referred to in column 1 in items 3 and 3.1 of the efficiency standards table in section 27 a include only those non-metal, non-wood framed windows and sliding glass doors that i separate heated space from non-heated space, and ii are installed in smaller buildings, and b do not include products referred to in section 19 [excluded windows, doors, curtain walls, window walls and storefront windows (for smaller buildings)] . 5 Wood framed windows and sliding glass doors (for smaller buildings) referred to in column 1 in items 4 and 4.1 of the efficiency standards table in section 27 a include only those wood framed windows and sliding glass doors that i separate heated space from non-heated space, and ii are installed in smaller buildings, and b do not include products referred to in section 19. 5.1 Windows and sliding glass doors (for smaller buildings) referred to in column 1 in item 4.2 of the efficiency standards table in section 27 a include only those windows and sliding glass doors that i separate heated space from non-heated space, and ii are installed in smaller buildings, and b do not include products referred to in section 19. 6 Skylights referred to in column 1 in items 5 and 5.1 of the efficiency standards table in section 27 a include only those skylights that separate heated space from non-heated space, and b do not include skylights installed in an energy compliant building. 7 Metal framed curtain walls, window walls and storefront windows (for smaller buildings) referred to in column 1 in items 6, 7 and 7.1 of the efficiency standards table in section 27 a include only those metal framed curtain walls, window walls and storefront windows that i separate heated space from non-heated space, and ii are installed in smaller buildings, and b do not include products referred to in section 19. 7.1 Non-metal curtain walls, window walls and storefront windows (for smaller buildings) referred to in column 1 in item 7.2 of the efficiency standards table in section 27 a include only those non-metal curtain walls, window walls and storefront windows that i separate heated space from non-heated space, and ii are installed in smaller buildings, and b do not include products referred to in section 19. 8 Hinged and bi-folding doors (for smaller buildings) referred to in column 1 in items 8 and 8.1 of the efficiency standards table in section 27 a include only those hinged and bi-folding doors that i are fully glazed into A an aluminum sash construction, B a fibreglass sash construction, or C a steel sash construction, ii separate heated space from non-heated space, and iii are installed in smaller buildings, and b do not include products referred to in section 19. 9 Metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows (for larger buildings) referred to in column 1 in item 9 of the efficiency standards table in section 27 a include only those metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows that i separate heated space from non-heated space, and ii are installed in larger buildings, and b do not include products referred to in section 20 [excluded windows, doors, curtain walls, window walls and storefront windows (for larger buildings)] . 10 Non-metal windows, sliding glass doors, curtain walls, window walls and storefront windows (for larger buildings) referred to in column 1 in item 10 of the efficiency standards table in section 27 a include only those non-metal windows, sliding glass doors, curtain walls, window walls and storefront windows that i separate heated space from non-heated space, and ii are installed in larger buildings, and b do not include products referred to in section 20. [am. B.C. Regs. 29/2018, Sch. 1, s. 8 and Sch. 2, s. 1; 35/2021, ss. 8 and 9; 106/2023, ss. 1 and 2.] Excluded door slabs 17 For the purposes of section 16 (2) (b), door slabs referred to in column 1 in item 1 of the efficiency standards table in section 27 [efficiency standards for manufactured fenestration products] do not include any of the following: a a solid wood door slab; b a door slab in a pre-hung door assembly with a maximum U-value of 1.80 W/[m 2 ×K], tested in accordance with NFRC 100-2014; c a door slab installed in a designated heritage building; d a door slab installed in an energy compliant building. [am. B.C. Reg. 29/2018, Sch. 1, s. 9.] Excluded glazing products 18 For the purposes of section 16 (3) (b), glazing products referred to in column 1 in item 2 of the efficiency standards table in section 27 [efficiency standards for manufactured fenestration products] do not include any of the following products: a a glazing product installed in a pre-hung door assembly with a maximum U-value of 1.80 W/[m 2 ×K], tested in accordance with NFRC 100-2014; b a decorative glazing contained in a sealed insulating glass unit that has one or more stained glass panels, iron inserts or blinds; c a glazing product installed in a designated heritage building; d a glazing product installed in an energy compliant building. [am. B.C. Reg. 29/2018, Sch. 1, s. 10.] Excluded windows, doors, curtain walls, window walls and storefront windows (for smaller buildings) 19 For the purposes of section 16 (4) (b), (5) (b), (5.1) (b), (7) (b), (7.1) (b) and (8) (b), the products referred to in column 1 in item 3, 3.1, 4, 4.1, 4.2, 6, 7, 7.1, 7.2, 8 or 8.1 of the efficiency standards table in section 27 [efficiency standards for manufactured fenestration products] do not include any of the following products: a a decorative window contained in a sealed insulating glass unit that has one or more stained glass panels, iron inserts or blinds; b a glazing replacement in an existing sash or frame, if the U-value of the replacement glazing is less than or equal to the U-value of the original glazing; c a window, curtain wall, window wall or storefront window installed in a designated heritage building; d a window, door, curtain wall, window wall or storefront window installed in an energy compliant building. [am. B.C. Regs. 29/2018, Sch. 1, s. 11; 35/2021, s. 10.] Excluded windows, doors, curtain walls, window walls and storefront windows (for larger buildings) 20 For the purposes of section 16 (9) (b) and (10) (b), the products referred to in column 1 in item 9 or 10 of the efficiency standards table in section 27 [efficiency standards for manufactured fenestration products] do not include any of the following products: a a glazing replacement in an existing sash or frame, if the U-value of the replacement glazing is less than or equal to the U-value of the original glazing; b a skylight; c a window, door, curtain wall, window wall or storefront window installed in a designated heritage building; d a window, door, curtain wall, window wall or storefront window installed in an energy compliant building. [am. B.C. Reg. 29/2018, Sch. 1, s. 12.] Letter of assurance for energy compliant buildings 21 1 For the purposes of sections 17 (d), 18 (d), 19 (d) and 20 (d), a letter of assurance that meets the requirements set out in subsection (2) of this section is evidence that a building is an energy compliant building. 2 The letter of assurance referred to in subsection (1) a must be issued for the building by a registered professional of record, within the meaning of the British Columbia Building Code Regulation, B.C. Reg. 264/2012, and b may be in the form set out under, as applicable, i Schedule C-B in section 2.2.7 of Division C of the British Columbia Building Code Regulation, or ii the building bylaws of the City of Vancouver. Placement of label on manufactured fenestration products 22 1 For the purposes of section 5 (3), an energy efficiency verification label must be placed on a manufactured fenestration product, other than a door slab, in one of the following ways: a by affixing the label to the frame or spacer bar of the manufactured fenestration product so that the label is visible at all times; b by affixing the label to the frame or sash of the manufactured fenestration product so that the label is visible when the sash is open; c by affixing the label as a transparent adhesive label to the glass of the manufactured fenestration product; d by etching the label into the surface of the glass of the manufactured fenestration product. 2 For the purposes of section 5 (3), an energy efficiency verification label must be placed on a door slab in one of the following ways: a by affixing the label to the door slab so that the label is visible at all times; b by affixing the label to the edge of the door slab so that the label is visible when the door is open. [am. B.C. Reg. 29/2018, Sch. 1, s. 13.] Additional label requirement for manufactured fenestration products 23 1 Subject to section 24, for the purposes of section 2 (1) (b) [prescribed label] of the Act, and in addition to an energy efficiency verification label and a manufacturing information label, a removable label that meets the requirements set out in subsection (2) of this section must be affixed to all manufactured fenestration products, other than door slabs and glazing products. 2 The removable label referred to in subsection (1) must set out the U-value, as determined by a designated tester, of a manufactured fenestration product as follows: a for a single operator type, the overall U-value of the manufactured fenestration product; b for a combination or composite manufactured fenestration product composed of 2 or more operator types, each of which has a different U-value, i the overall U-value of the manufactured fenestration product, or ii the individual U-value for each of the operator types in the manufactured fenestration product. 3 Section 5 (3) [energy efficiency verification label] applies to the removable label referred to in subsection (1) as if the removable label were an energy efficiency verification label. [am. B.C. Reg. 29/2018, Sch. 1, s. 14.] Label exemption for manufactured fenestration products designed for specific buildings 24 1 For a manufactured fenestration product, other than a door slab or glazing product, an energy efficiency verification label, a manufacturing information label and the removable label required under section 23 are not required if a the manufactured fenestration product is designed for a specific building, and b a certificate meeting the requirements set out in subsection (2) of this section is posted at the specific building site. 2 For the purposes of subsection (1) (b), the requirements for the certificate are as follows: a the certificate must set out i the U-value, as determined by a designated tester, for each manufactured fenestration product provided for the specific building, or ii for manufactured fenestration products to which section 25 applies, the average U-value, as determined by a designated tester, for each type of manufactured fenestration product provided for the specific building; b the certificate must be issued by a designated tester; c the certificate must be posted in plain view at the specific building site for a period of at least 120 days after the last of the manufactured fenestration products is installed in that specific building. d Repealed. [B.C. Reg. 35/2021, s. 11.] [am. B.C. Regs. 29/2018, Sch. 1, s. 15 and Sch. 2, s. 2; 35/2021, s. 11.] Efficiency standard exemption for manufactured fenestration products designed for specific buildings 25 For manufactured fenestration products, other than door slabs and glazing products, that are designed for a specific building, if 2 or more of the same type of manufactured fenestration products are installed in the specific building, the applicable efficiency standard for each manufactured fenestration product of that type may be met by demonstrating that the average U-value, as determined by a designated tester, of those manufactured fenestration products meets the applicable efficiency standard. Calculation of U-value for atypical manufactured fenestration products 26 For a manufactured fenestration product, other than a door slab or glazing product, for which the U-value, by reason of its atypical shape, size or other feature, cannot be determined by a designated tester using standard testing procedures, the actual size of the manufactured fenestration product may be used for calculating the U-value of that manufactured fenestration product. Efficiency standards for manufactured fenestration products 27 The following efficiency standards table sets out the efficiency standards for energy devices that are manufactured fenestration products: Item Column 1 Energy Device Column 2 Prescribed Date (s. 2 (3) (a) of Act) Column 3 Manufacturing Period Column 4 Efficiency Standard Column 5 Testing Procedure 1 Door slabs (for exclusions, see sections 16 (2) and 17) June 1, 2009 Products manufactured on or after June 2, 2009 The door panels must be insulated with products with an RSI ≥ 0.875 m 2 ×K/W ASTM C518-04 or ASTM C518-10 2 Glazing products (for exclusions, see sections 16 (3) and 18) June 1, 2009 Products manufactured on or after June 2, 2009 The glazing product (a) must be multiple glazed with at least one low-emissivity coating between glazing, (b) must have a 90% argon gas fill level with a compatible edge sealant system, and (c) must have spacer bars and if the spacer bars are aluminum box spacer bars, the aluminum box spacer bars must have a thermal break. Not applicable 3 Non-metal, non-wood framed windows and sliding glass doors (for smaller buildings) (for exclusions, see sections 16 (4) and 19) March 1, 2009 Products manufactured between March 2, 2009 and June 1, 2018 U-value must be ≤ 2.0 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN/CSA A440.2-04/A440.3-04; (b) CAN/CSA A440.2-09/A440.3-09; (c) NFRC 100-2004 or NFRC 100-2010. 3.1 Non-metal, non-wood framed windows and sliding glass doors (for smaller buildings) (for exclusions, see sections 16 (4) and 19) June 1, 2018 Products manufactured between June 2, 2018 and January 1, 2022 U-value must be ≤ 1.80 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN-CSA A440.2-14/A440.3-14; (b) NFRC 100-2014. 4 Wood framed windows and sliding glass doors (for smaller buildings) (for exclusions, see sections 16 (5) and 19) Jan 1, 2011 Products manufactured between Jan 2, 2011 and June 1, 2018 U-value must be ≤ 2.0 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN/CSA A440.2-04/A440.3-04; (b) CAN/CSA A440.2-09/A440.3-09; (c) NFRC 100-2004 or NFRC 100-2010. 4.1 Wood framed windows and sliding glass doors (for smaller buildings) (for exclusions, see sections 16 (5) and 19) June 1, 2018 Products manufactured between June 2, 2018 and January 1, 2022 U-value must be ≤ 1.80 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN-CSA A440.2-14/A440.3-14; (b) NFRC 100-2014. 4.2 Windows and sliding glass doors (for smaller buildings) (for exclusions, see sections 16 (5.1) and 19) Jan 1, 2022 Products manufactured on or after Jan 2, 2022 U-value must be ≤ 1.61 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN/CSA A440.2-14/A440.3-14; (b) CAN/CSA A440.2-19/A440.3-19; (c) NFRC 100-2014; (d) NFRC 100-2017. 5 Skylights (for exclusions, see section 16 (6)) March 1, 2009 Products manufactured between March 2, 2009 and June 1, 2018 U-value must be ≤ 3.10 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN/CSA A440.2-04/A440.3-04; (b) CAN/CSA A440.2-09/A440.3-09; (c) NFRC 100-2004 or NFRC 100-2010. 5.1 Skylights (for exclusions, see section 16 (6)) June 1, 2018 Products manufactured on or after June 2, 2018 U-value must be ≤ 2.90 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN-CSA A440.2-14/A440.3-14; (b) NFRC 100-2014. 6 Metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows (for smaller buildings) (for exclusions, see sections 16 (7) and 19) June 1, 2009 Products manufactured between June 2, 2009 and Jan 1, 2011 U-value must be ≤ 2.57 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN/CSA A440.2-04/A440.3-04; (b) CAN/CSA A440.2-09/A440.3-09; (c) NFRC 100-2004 or NFRC 100-2010. 7 Metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows (for smaller buildings) (for exclusions, see sections 16 (7) and 19) Jan 1, 2011 Products manufactured between Jan 2, 2011 and June 1, 2018 U-value must be ≤ 2.0 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN/CSA A440.2-04/A440.3-04; (b) CAN/CSA A440.2-09/A440.3-09; (c) NFRC 100-2004 or NFRC 100-2010. 7.1 Metal framed curtain walls, window walls and storefront windows (for smaller buildings) (for exclusions, see sections 16 (7) and 19) June 1, 2018 Products manufactured on or after June 2, 2018 U-value must be ≤ 1.80 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN-CSA A440.2-14/A440.3-14; (b) NFRC 100-2014. 7.2 Non-metal curtain walls, window walls and storefront windows (for smaller buildings) (for exclusions, see sections 16 (7.1) and 19) June 1, 2018 Products manufactured on or after June 2, 2018 U-value must be ≤ 1.80 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN-CSA A440.2-14/A440.3-14; (b) NFRC 100-2014. 8 Hinged and bi-folding doors (for smaller buildings) (for exclusions, see sections 16 (8) and 19) Jan 1, 2012 Products manufactured between Jan 2, 2012 and June 1, 2018 U-value must be ≤ 2.0 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN/CSA A440.2-04/A440.3-04; (b) CAN/CSA A440.2-09/A440.3-09; (c) NFRC 100-2004 or NFRC 100-2010. 8.1 Hinged and bi-folding doors (for smaller buildings) (for exclusions, see sections 16 (8) and 19) June 1, 2018 Products manufactured on or after June 2, 2018 U-value must be ≤ 1.80 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN-CSA A440.2-14/A440.3-14; (b) NFRC 100-2014. 9 Metal framed windows, sliding glass doors, curtain walls, window walls and storefront windows (for larger buildings) (for exclusions, see sections 16 (9) and 20) Jan 1, 2011 Products manufactured on or after Jan 2, 2011 U-value must be ≤ 2.57 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN/CSA A440.2-04/A440.3-04; (b) CAN/CSA A440.2-09/A440.3-09; (c) NFRC 100-2004 or NFRC 100-2010. 10 Non-metal windows, sliding glass doors, curtain walls, window walls and storefront windows (for larger buildings) (for exclusions, see sections 16 (10) and 20) Jan 1, 2011 Products manufactured on or after Jan 2, 2011 U-value must be ≤ 2.0 W/[m 2 ×K] The procedure set out in one of the following: (a) CAN/CSA A440.2-04/A440.3-04; (b) CAN/CSA A440.2-09/A440.3-09; (c) NFRC 100-2004 or NFRC 100-2010. [am. B.C. Regs. 29/2018, Sch. 1, s. 16; 35/2021, s. 12; 106/2023, s. 3.] Definitions 28 In this Part: CAN/CSA C300-M91 means CSA standard CAN/CSA C300-M91 entitled Capacity Measurement and Energy Consumption Test Methods for Refrigerators, Combination Refrigerator-Freezers and Freezers ; CAN/CSA C300-15 means CSA standard CAN/CSA C300-15 entitled Energy performance and capacity of household refrigerators, refrigerator-freezers, freezers and wine chillers ; CAN/CSA C360-13 means CSA standard CAN/CSA C360-13 entitled Energy performance, water consumption and capacity of household clothes washers ; CAN/CSA C373-14 means CSA standard CAN/CSA C373-14 entitled Energy performance and water consumption of household dishwashers ; clothes washer means a household automatic clothes washer that is electrically operated; combination refrigerator-freezer means a household combination refrigerator-freezer that has a a defrost system, and b a capacity of up to 1 105 litres; compact clothes washer means a clothes washer that has a capacity of less than 1.6 ft 3 ; compact dishwasher means a dishwasher that has the capacity to hold up to 8 place settings; dishwasher means a household automatic dishwasher that is electrically operated, but does not include a commercial, industrial or institutional dishwasher; freezer means a household freezer that has a capacity of up to 850 litres; refrigerator means a household refrigerator that a has a capacity of up to 1 105 litres, b has a defrost system, and c does not use an absorption refrigeration system; standard capacity clothes washer means a clothes washer that has a capacity of 1.6 ft 3 or more; standard capacity dishwasher means a dishwasher that has the capacity to hold more than 8 place settings. [am. B.C. Reg. 35/2021, s. 13.] Label exemption for clothes washers, dishwashers, refrigerators, combination refrigerator-freezers and freezers compliant with federal Act 29 An energy efficiency verification label is not required for an energy device that is a clothes washer, dishwasher, refrigerator, combination refrigerator-freezer or freezer if, in respect of the energy device, a the information required under section 5 (1) [information to be provided by dealers] of the federal Act has been provided to the federal minister, or b the manufacturer of the energy device provides a copy of the information required under section 5 (1) of the federal Act to an inspector designated under section 3 [inspection and testing] of the Act. [am. B.C. Reg. 29/2018, Sch. 1, s. 5.] Efficiency standards for household appliances 30 The following efficiency standards table sets out the efficiency standards for energy devices that are household appliances: Item Column 1 Energy Device Column 2 Prescribed Date (s. 2 (3) (a) of Act) Column 3 Manufacturing Period Column 4 Efficiency Standard Column 5 Testing Procedure 1 Compact clothes washers that are top loading May 31, 2015 Products manufactured between June 1, 2015 and Dec 31, 2017 Integrated modified energy factor must be ≥ 0.86 ft 3 /kWh/cycle CAN/CSA C360-13 Integrated water factor must be ≤ 14.4 gal/cycle/ft 3 CAN/CSA C360-13 2 Compact clothes washers that are top loading Dec 31, 2017 Products manufactured on or after Jan 1, 2018 Integrated modified energy factor must be ≥ 1.15 ft 3 /kWh/cycle CAN/CSA C360-13 Integrated water factor must be ≤ 12 gal/cycle/ft 3 CAN/CSA C360-13 3 Standard capacity clothes washers that are top loading May 31, 2015 Products manufactured between June 1, 2015 and Dec 31, 2017 Integrated modified energy factor must be ≥ 1.29 ft 3 /kWh/cycle CAN/CSA C360-13 Integrated water factor must be ≤ 8.4 gal/cycle/ft 3 CAN/CSA C360-13 4 Standard capacity clothes washers that are top loading Dec 31, 2017 Products manufactured on or after Jan 1, 2018 Integrated modified energy factor must be ≥ 1.57 ft 3 /kWh/cycle CAN/CSA C360-13 Integrated water factor must be ≤ 6.5 gal/cycle/ft 3 CAN/CSA C360-13 5 Compact clothes washers that are front loading May 31, 2015 Products manufactured on or after June 1, 2015 Integrated modified energy factor must be ≥ 1.13 ft 3 /kWh/cycle CAN/CSA C360-13 Integrated water factor must be ≤ 8.3 gal/cycle/ft 3 CAN/CSA C360-13 6 Standard capacity clothes washers that are front loading Dec 31, 2017 Products manufactured on or after Jan 1, 2018 Integrated modified energy factor must be ≥ 1.84 ft 3 /kWh/cycle CAN/CSA C360-13 Integrated water factor must be ≤ 4.7 gal/cycle/ft 3 CAN/CSA C360-13 7 Compact dishwashers (for exclusions, see the definition of "dishwasher" in section 28) May 31, 2015 Products manufactured on or after June 1, 2015 Estimated annual energy use must be ≤ 222 kWh/yr CAN/CSA C373-14 Water consumption must be ≤ 3.5 gal/cycle CAN/CSA C373-14 8 Standard capacity dishwashers (for exclusions, see the definition of "dishwasher" in section 28) May 31, 2015 Products manufactured on or after June 1, 2015 Estimated annual energy use must be ≤ 307 kWh/yr CAN/CSA C373-14 Water consumption must be ≤ 5.0 gal/cycle CAN/CSA C373-14 9 Combination refrigerator-freezers, freezers and refrigerators Jan 1, 1994 Products manufactured between Jan 2, 1994 and Apr 1, 2021 Standard set out in column 4 of CAN/CSA C300-M91 CAN/CSA C300-M91 9.1 Combination refrigerator-freezers, freezers and refrigerators Apr 1, 2021 Products manufactured on or after Apr 2, 2021 Standard set out in Table 1 of CAN/CSA C300-15 CAN/CSA C300-15 [am. B.C. Regs. 29/2018, Sch. 1, s. 17; 35/2021, s. 14.] Definitions 31 In this Part: AFUE means annual fuel utilization efficiency; AHRI means the Air-Conditioning, Heating, and Refrigeration Institute; ANSI Z21.13-2004/CSA 4.9-2004 means ANSI standard ANSI Z21.13-2004/CSA 4.9-2004 entitled Gas-Fired Low Pressure Steam and Hot Water Boilers ; ANSI Z21.50-2016/CSA 2.22-2016 means ANSI standard ANSI Z21.50-2016/CSA 2.22-2016 entitled Vented decorative gas appliances ; ANSI Z21.88-2016/CSA 2.33-2016 means ANSI standard ANSI Z21.88-2016/CSA 2.33-2016 entitled Vented gas fireplace heaters ; ANSI/AHRI 1500 means ANSI/AHRI standard ANSI/AHRI 1500 entitled 2015 Standard for Performance Rating of Commercial Space Heating Boilers ; CAN/CSA C828-13 means CSA standard CAN/CSA C828-13 entitled Performance Requirements for Thermostats Used With Individual Room Electric Space Heating Devices ; CAN/CSA P.2-13 means CSA standard CAN/CSA P.2-13 entitled Testing method for measuring the annual fuel utilization efficiency of residential gas-fired or oil-fired furnaces and boilers ; CAN/CSA P.4.1-02 means CSA standard CAN/CSA P.4.1-02 entitled Testing Method for Measuring Annual Fireplace Efficiency ; CAN/CSA P.4.1-15 means CSA standard CAN/CSA-P.4.1-15 entitled Testing method for measuring annual fireplace efficiency ; commercial gas boiler means a boiler that a is fired by propane or natural gas, b is intended for application in a hot water central heating system or in a potable water service, and c has an input rating of i no less than 87.92 kW (300 000 BTU/h), and ii no more than 2 930.71 kW (10 000 000 BTU/h); commercial gas boiler — large means a commercial gas boiler that has an input rating of a more than 732.68 kW (2 500 000 BTU/h), and b no more than 2 930.71 kW (10 000 000 BTU/h); commercial gas boiler — small means a commercial gas boiler that has an input rating of a no less than 87.92 kW (300 000 BTU/h), and b no more than 732.68 kW (2 500 000 BTU/h); CSA C828:19 means CSA standard CSA C828:19 entitled Performance Requirements for Line Voltage Thermostats Used With Individual Room Electric Space Heating Devices ; FE rating means the annual fireplace efficiency rating of a gas fireplace, vented gas fireplace heater or vented decorative gas appliance; GAMA BTS-2000 means GAMA BTS-2000 standard of the Hydronics Institute Division of the Air Conditioning, Heating and Refrigeration Institute (USA) entitled Method to Determine Efficiency of Commercial Space Heating Boilers ; gas fireplace means a gas fireplace that uses propane or natural gas, including an insert or free-standing stove; gas furnace has the same meaning as in the federal regulation; HSPF means the heating seasonal performance factor, expressed in British thermal units per watt-hour or BTU/watt-hr; outdoor gas furnace means a gas furnace that uses a single-phase electric current and is for use outdoors; replacement gas furnace means a gas furnace for use as a replacement furnace in a residential building; residential gas boiler means a boiler that a is fired by propane or natural gas, b is intended for application in a hot water central space heating system, c may service a potable hot water system, and d has an input rating of less than 87.92 kW (300 000 BTU/h); thermostat means a thermostat used for switching of a controlled resistive 120 or 240 volt heating load, but does not include any of the following: a a single thermostat used to control a central heating unit; b a thermostat in a portable heater; c a thermostat used exclusively to control i a fan-forced heater, ii a fireplace, or iii a radiant floor heater; d a built-in line voltage thermostat used to control a baseboard heater, or panel convector heater, that has a maximum rated heat output of 1 000 watts; through-the-wall gas furnace means a through-the-wall gas furnace that uses a single-phase electric current; vented decorative gas appliance means a vented decorative gas appliance that is within the scope of ANSI Z21.50-2016/CSA 2.22-2016; vented gas fireplace heater means a vented gas fireplace heater that is within the scope of ANSI Z21.88-2016/CSA 2.33-2016. [en. B.C. Reg. 29/2018, Sch. 1, s. 18; am. B.C. Regs. 35/2021, s. 15; 106/2023, s. 4.] Label exemption for gas furnaces and residential gas boilers compliant with federal Act 32 An energy efficiency verification label is not required for an energy device that is a gas furnace or residential gas boiler if, in respect of the energy device, a the information required under section 5 (1) [information to be provided by dealers] of the federal Act has been provided to the federal minister, or b the manufacturer of the energy device provides a copy of the information required under section 5 (1) of the federal Act to an inspector designated under section 3 [inspection and testing] of the Act. [en. B.C. Reg. 35/2021, s. 16.] Label exemption for commercial gas boilers with reported information or compliant with federal Act 32.1 An energy efficiency verification label is not required for an energy device that is a commercial gas boiler if any of the following apply: a the energy efficiency performance information set out for the energy device in the AHRI Directory of Certified Product Performance demonstrates compliance with the energy standard set out in column 4 in item 13.2 or item 13.3, as the case may be, of the efficiency standards table in section 34; b the energy efficiency performance information set out for the energy device in the United States Department of Energy Compliance Certification Database demonstrates compliance with the energy standard set out in column 4 in item 13.2 or item 13.3, as the case may be, of the efficiency standards table in section 34; c the information required under section 5 (1) [information to be provided by dealers] of the federal Act has been provided to the federal minister; d the manufacturer of the energy device provides a copy of the information required under section 5 (1) of the federal Act to an inspector designated under section 3 [inspection and testing] of the Act. [en. B.C. Reg. 35/2021, s. 17.] FE rating and label requirements for gas fireplaces 33 1 An FE rating for a gas fireplace manufactured between January 2, 2007 and December 31, 2018 must be determined in accordance with one of the testing procedures referred to in column 5 in item 12 of the efficiency standards table in section 34. 2 For the purposes of section 2 (1) (b) [prescribed label] of the Act, an energy efficiency verification label for a gas fireplace referred to in subsection (1) of this section must set out the FE rating for the gas fireplace. [en. B.C. Reg. 29/2018, Sch. 1, s. 19.] FE rating and label requirements for vented gas fireplace heaters and vented decorative gas appliances 33.1 1 An FE rating for a vented gas fireplace heater or vented decorative gas appliance manufactured on or after January 1, 2019 must be determined in accordance with the testing procedure referred to in column 5 in item 12.1 or 12.2, as applicable, of the efficiency standards table in section 34. 2 For the purposes of section 2 (1) (b) [prescribed label] of the Act, an energy efficiency verification label for a vented gas fireplace heater or vented decorative gas appliance referred to in subsection (1) of this section must, a in the case of a vented gas fireplace heater, set out the FE rating for the vented gas fireplace heater, and b in the case of a vented decorative gas appliance, i set out the FE rating for the vented decorative gas appliance, and ii indicate that the vented decorative gas appliance is a decorative product and is not intended to be used as a heating appliance. [en. B.C. Reg. 29/2018, Sch. 1, s. 19.] Pl

    The text continues in the official source.

    Contains information licensed under the King’s Printer Licence for British Columbia. This reproduction is not an official copy.

    Related guides, FAQ and contract templates